SEMAC-VAT MR Imaging Unravels Peri-instrumentation Lesions in Patients With Attendant Symptoms After Spinal Surgery
Authors:
- Shun QiSQShun Qi
- Zhi-Gang WuZWZhi-Gang Wu
- Yun-Feng MuYMYun-Feng Mu
- Lang-Lang GaoLGLang-Lang Gao
- Jian YangJYJian Yang
- Pan-Li ZuoPZPan-Li Zuo
- Mathias NittkaMNMathias Nittka
- Ying LiuYLYing Liu
- Hai-Qiang WangHWHai-Qiang Wang
- Hong YinHYHong Yin
Open Access
- 1 April 2016
- journal article
- Published by Wolters Kluwer Health in Medicine
- Vol. 95 (14) , e3184
Abstract
The study aimed for evaluating the diagnostic value of a 2D Turbo Spin Echo (TSE) magnetic resonance (MR) imaging sequence implanted slice-encoding metal artifact correction (SEMAC) and view-angle tilting (VAT) in patients with spinal instrumentation.Sixty-seven consecutive patients with an average age of 59.7 ± 17.8 years old (range: 32-75 years) were enrolled in this study. Both sagittal, axial T1-weighted and T2-weighted MRI images were acquired with a standard TSE sequence and a high-bandwidth TSE sequence implemented the SEMAC and VAT techniques. Three continuous sections around the instrumentation in axial and sagittal images were selected for quantitative evaluation. The measurement included cumulative areas of signal void on axial images and the length of spinal canal obscuration on sagittal images. Three radiologists independently evaluated all images blindly. The inter-observer reliability was evaluated with inter-class coefficient. We defined patients with discomfortable symptoms caused by spinal instrumentation as spinal instrumentation adverse reaction.Visualizations of all periprosthetic anatomic structures were significantly better for SEMAC-VAT compared with standard imaging. For axial images, the area of signal void at the level of the instrumentation were statistically reduced with SEMAC-VAT TSE sequences than with standard TSE sequences for T2-weighted images (9.9 ± 2.6 cm vs 29.8 ± 14.7 cm, P < 0.001). For sagittal imaging, the length of spinal canal obscuration at the level of the instrumentation was reduced from 5.2 ± 2.0 cm to 1.2 ± 0.6 cm on T2-weighted images (P < 0.001), and from 4.8 ± 2.1 cm to 1.1 ± 0.5 cm on T1-weighted images with SEMAC-VAT sequences (P < 0.001). Interobserver agreement for visualization of anatomic structures and image quality was good for both SEMAC-VAT (k = 0.77 and 0.68, respectively) and standard (k = 0.74 and 0.80, respectively) imaging. The number of abnormal findings noted on SEMAC images (59 findings) was significantly higher than detected on standard images (40 findings). The incidence rate of spinal instrumentation adverse reaction was 38.81%.MR images with SEMAC-VAT can significantly reduce metal artifacts for spinal instrumentation and improve delineation of the instrumentation and periprosthetic region. Furthermore, SEMAC-VAT technique can improve diagnostic accuracy in patients with post-instrumentation spinal diseases.Keywords
This publication has 24 references indexed in Scilit:
- Metal Artifact ReductionRadiologic Clinics of North America, 2015
- Phantom based qualitative and quantitative evaluation of artifacts in MR images of metallic hip prosthesesPhysica Medica, 2015
- Evaluation of metal artifacts in clinical MR images of patients with total hip arthroplasty using different metal artifact-reducing sequencesSkeletal Radiology, 2014
- Feasibility of fat-saturated T2-weighted magnetic resonance imaging with slice encoding for metal artifact correction (SEMAC) at 3TMagnetic Resonance Imaging, 2014
- Reduction of Metal Artifacts in Patients with Total Hip Arthroplasty with Slice-encoding Metal Artifact Correction and View-Angle Tilting MR ImagingRadiology, 2012
- New MR imaging methods for metallic implants in the knee: Artifact correction and clinical impactJournal of Magnetic Resonance Imaging, 2011
- Slice encoding for metal artifact correction with noise reductionMagnetic Resonance in Medicine, 2011
- SEMAC: Slice encoding for metal artifact correction in MRIMagnetic Resonance in Medicine, 2009
- Improved MR imaging for patients with metallic implants☆Magnetic Resonance Imaging, 2000
- Susceptibility artefacts in NMR imagingMagnetic Resonance Imaging, 1985