Potential for Radiation Dose Reduction in Dual-Source Computed Tomography of the Lung in the Pediatric and Adolescent Population Compared to Digital Radiography
Authors:
- Matthias WetzlMWMatthias Wetzl
- Matthias Stefan MayMatthias Stefan May
- Daniel WeinmannDWDaniel Weinmann
- Matthias HammonMHMatthias Hammon
- Markus KoppMKMarkus Kopp
- Renate RuppelRRRenate Ruppel
- Regina TrollmannRTRegina Trollmann
- Joachim WoelfleJWJoachim Woelfle
- Michael UderMUMichael Uder
- Oliver RompelOROliver Rompel
Open Access
- 10 February 2021
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 11 (2) , 270
Abstract
Low-dose dual-source computed tomography (DSCT) protocols for the evaluation of lung diseases in children and adolescents are of importance since this age group is particularly prone to radiation damage. The aim of this study was to evaluate image quality of low-dose DSCT of the lung and to assess the potential of radiation dose reduction compared to digital radiographs (DR). Three groups, each consisting of 19 patients, were examined with different DSCT protocols using tin prefiltration (Sn96/64/32 ref. mAs at 100 kV). Different strengths of iterative reconstruction were applied (ADMIRE 2/3/4). DSCT groups were compared to 19 matched patients examined with posterior–anterior DR. Diagnostic confidence, detectability of anatomical structures and small lung lesions were evaluated on a 4-point Likert scale (LS 1 = unacceptable, 4 = fully acceptable; a value ≥ 3 was considered acceptable). Effective dose (ED) was 31-/21-/9-fold higher in Sn96/Sn64/Sn32 compared to DR. Diagnostic confidence was sufficient in Sn96/Sn64 (LS 3.4/3.2), reduced in Sn32 (LS 2.7) and the worst in DR (LS 2.4). In DSCT, detectability of small anatomical structures was always superior to DR (p < 0.05). Mean lesion size ranged from 5.1–7 mm; detectability was acceptable in all DSCT groups (LS 3.0–3.4) and superior to DR (LS 1.9; p < 0.05). Substantial dose lowering in DSCT of the pediatric lung enables acceptable detectability of small lung lesions with a radiation dose being about 10-fold higher compared to DR.Keywords
This publication has 25 references indexed in Scilit:
- Very Low-Dose (0.15 mGy) Chest CT Protocols Using the COPDGene 2 Test Object and a Third-Generation Dual-Source CT Scanner With Corresponding Third-Generation Iterative Reconstruction SoftwareInvestigative Radiology, 2015
- Ultralow-Dose Chest Computed Tomography for Pulmonary Nodule DetectionInvestigative Radiology, 2014
- Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosisPediatric Radiology, 2012
- Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility studyPediatric Radiology, 2011
- Radiation dose from coronary CT angiography: Five years of progressJournal of Cardiovascular Computed Tomography, 2010
- Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length ProductRadiology, 2010
- Zur Strahlenexposition von Kindern in der pädiatrischen RadiologieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2008
- An outlook on x‐ray CT research and developmentMedical Physics, 2008
- Noise and resolution in images reconstructed with FBP and OSC algorithms for CTMedical Physics, 2007
- Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CTAmerican Journal of Roentgenology, 2001