Prospective randomized controlled clinical study comparing two dental implant types: volumetric soft tissue changes at 1 year of loading
- 26 February 2015
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 27 (4) , 406-411
Abstract
To evaluate the volumetric changes occurring from prosthesis insertion to the 1-year follow-up (FU) using one- and two-piece dental implants.Sixty patients were randomly assigned to receive one-piece or two-piece implants. Casts were obtained at baseline (insertion of final reconstruction) and at 1 year of loading. Finally, 33 pairs of casts (BRA = 18, STM = 15) were deemed appropriate for volumetric analysis of the peri-implant tissues. If the patients had more than one implant, one was randomly selected for analysis. Casts were scanned to obtain stereolithography (STL) files. Baseline and 1-year FU digital models were superimposed with an image analysis program. Linear and volumetric measurements were performed including (i) crown height changes (CHCs), (ii) volumetric changes, and (iii) changes in tissue thickness at three levels below the mucosal margin on the buccal side of the implants (at 1,3, and 5 mm). The Mann-Whitney U-test and the paired t-test were used to analyze the data between the two groups using the patient as the unit of analysis.No significant baseline differences were observed between the one- and two-piece groups for the linear measurements. The mean CHCs in the two-piece group amounted to 0.02 mm (SD ± 0.32), whereas the one-piece group exhibited a change of -0.17 mm (±0.57). The mean volume changes (VCs) were -0.12 mm (±0.27) (two-piece group) and -0.03 mm (±0.29) (one-piece group). With regard to the changes in tissue thickness, the two-piece group presented a change of -0.15 mm (±0.20) at 1 mm, -0.06 mm (±0.20) at 3 mm, and -0.2 mm (±0.51) at 5 mm. The respective values for the one-piece group were -0.03 mm (±0.35), 0.01 mm (±0.28), and -0.01 mm (±0.51) at the three levels. None of the differences in linear measurements between baseline and the 1-year FU reached significance. Positive correlations were seen for tissue thickness changes at 1 and 3 mm for both groups (P < 0.05). Significant positive correlations were found for VCs and tissue thickness at 1 mm for the two-piece group and for VCs and tissue thickness at 1,3, and 5 mm for the one-piece group (P < 0.05).Within the first year of loading, minimal changes occur with regard to tissue thickness, crown height, and facial volume for both implant types.Keywords
Funding Information
- International Trachoma Initiative
This publication has 22 references indexed in Scilit:
- Predictors of inter‐proximal and midfacial recession following single implant treatment in the anterior maxilla: a multivariate analysisJournal of Clinical Periodontology, 2012
- A systematic review on the frequency of advanced recession following single immediate implant treatmentJournal of Clinical Periodontology, 2012
- Systematic review of parameters and methods for the professional assessment of aesthetics in dental implant researchJournal of Clinical Periodontology, 2012
- Single implants with different neck designs in the aesthetic zone: a randomized clinical trialClinical Oral Implants Research, 2011
- A Prospective Multicenter 5‐Year Radiographic Evaluation of Crestal Bone Levels Over Time in 596 Dental Implants Placed in 192 PatientsJournal of Periodontology, 2009
- Immediate Implant Placement Postextraction Without Flap ElevationJournal of Periodontology, 2009
- Soft tissue management at implant sitesJournal of Clinical Periodontology, 2008
- A Three‐Year Follow‐Up Report of a Comparative Study of ITI Dental Implants® and Brånemark System® Implants in the Treatment of the Partially Edentulous MaxillaClinical Implant Dentistry and Related Research, 2004
- Force transmission of one‐ and two‐piece morse‐taper oral implants: a nonlinear finite element analysisClinical Oral Implants Research, 2004
- Nonsubmerged and Submerged Implants in the Treatment of the Partially Edentulous MaxillaClinical Implant Dentistry and Related Research, 2002