Yoshihiro Kato
Yoshihiro Kato has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Kar-Hooi Cheong
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, JAPAN
1 shared publication - Kazunori Kageyama
Saitama City Foundation for Business Creation (SFBC), Saitama City 338-0002, Japan
1 shared publication - Masaharu Nakagawa
Irie Koken Co., Ltd. (IKC), Tokyo 100-0005, Japan
1 shared publication - Noriyuki Furuichi
National Metrology Institute of Japan (NMIJ)
1 shared publication - Ruriko Karasawa
Irie Koken Co., Ltd. (IKC), Tokyo 100-0005, Japan
1 shared publication - Ryouji Doihara
National Institute of Advanced Industrial Science and Technology
1 shared publication
Latest Publications
- Open Access
- 23 August 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8421
Optimum Pressurization Mechanism for a Non-Electrical Piston-Driven Infusion Pump
Intravenous (IV) fluid therapy is a common current medical practice, and the method has remained unchanged for more than a century. The IV bag is suspended from an IV stand or pole, and the pressure created by gravity is used to administer the drug. However, this method inevitably reduces the mobility of patients, and may cause accidents such as falls during movement. To solve these problems faced in home care, nursing home, and hospital settings, this study aims to develop a non-hanging, non-electrically driven IV infusion pump with reasonable portability and operability. In this study, instead of gravity, atmospheric pressure was used as the driving force. We developed several prototypes based on different pressurization mechanisms using vacuum piston cylinders as the driving mechanism, in order to find an optimum mechanism capable of producing a stable flow rate comparable to the suspended drip system. Tests on performance in terms of discharge flow rate were conducted on three feasible prototypes, based on three different pressurization mechanisms, using a gravimetric test bench built for this purpose. The tests showed that the pressurization mechanism using an inflating sleeping-bag-shaped air bag to compress a drip bag achieved the best performance in terms of flow rate stability.
- 23 August 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8421
Open AccessOptimum Pressurization Mechanism for a Non-Electrical Piston-Driven Infusion Pump
Intravenous (IV) fluid therapy is a common current medical practice, and the method has remained unchanged for more than a century. The IV bag is suspended from an IV stand or pole, and the pressure created by gravity is used to administer the drug. However, this method inevitably reduces the mobility of patients, and may cause accidents such as falls during movement. To solve these problems faced in home care, nursing home, and hospital settings, this study aims to develop a non-hanging, non-electrically driven IV infusion pump with reasonable portability and operability. In this study, instead of gravity, atmospheric pressure was used as the driving force. We developed several prototypes based on different pressurization mechanisms using vacuum piston cylinders as the driving mechanism, in order to find an optimum mechanism capable of producing a stable flow rate comparable to the suspended drip system. Tests on performance in terms of discharge flow rate were conducted on three feasible prototypes, based on three different pressurization mechanisms, using a gravimetric test bench built for this purpose. The tests showed that the pressurization mechanism using an inflating sleeping-bag-shaped air bag to compress a drip bag achieved the best performance in terms of flow rate stability.