Similar femoral stem fixation but less metaphyseal loss of bone mineral density with a taper-wedge design and diaphyseal bone preservation with a long and round-tapered design: a 5-year randomized RSA and DXA study of 50 patients
Open Access
- 2 September 2025
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 96, 656–663
Abstract
Background and purpose: The new Tri-Lock bone -preserving stem with a collarless proximal-coated tapered-wedge design was compared with a classic well-proven collarless proximal-coated long and round-tapered design. Our primary aim was to compare femoral stem fixation (subsidence) of the Tri-Lock stem with the classic Summit stem, and secondarily to compare the change in periprosthetic bone mineral density (BMD) and PROMS between stem groups.Methods: In a patient-blinded randomized controlled trial, 52 patients at mean age 60 (SD 6) received cementless Tri-Lock (n = 26) or Summit (n = 26) femoral stems with a cementless Pinnacle cup, a cross-linked polyethylene liner, and a CoCr head. Patients were followed for 5 years with radiostereometric analysis (RSA), dual-energy X-ray absorptiometry (DXA), and patient-reported outcome measures (PROMs). We measured mean (CI) values of migration and periprosthetic bone mineral density and calculated between group differences.Results: At 2-year follow-up, the mean difference in subsidence was 0.14 mm (95% confidence interval [CI] –0.27 to 0.56) and below the chosen minimal clinically important difference of 0.6 mm. At 5-year follow-up, for the Tri-Lock and Summit stems, the mean subsidence was 0.38 (CI 0.04–0.72) and 0.24 (CI 0.09–0.57), and the mean retroversion was 1.68° (CI 0.80–2.55) and 1.53° (CI 0.68–2.37), respectively. There was initial periprosthetic BMD loss for both stems. At 5-year follow-up, the mean metaphyseal bone loss was minimal for the Tri-Lock stem (zone 1: –2.8% vs –11.5%) while the Summit stem preserved the medial diaphyseal bone better (zone 6: –7.1% vs –13.6%). At the medial stem tip, BMD was increased with the Summit stem (zone 5: +3.4% vs –1.5%). At 5-year follow-up, median EQ5D was 1 in both groups and median Oxford Hip Score was 47 (Tri-Lock) and 45 (Summit) with no statistical significant differences between groups.Conclusion: The Tri-Lock and the Summit stems displayed similar migration until mid-term follow-up. At 3 months both stems had lost metaphyseal periprosthetic bone mineral density (BMD). During the following years, the new design regained more metaphyseal BMD. Contrarily, the long and round-tapered stem design regained or even increased diaphyseal BMD. PROM scores improved beyond the reference level for both groups.Keywords
This publication has 38 references indexed in Scilit:
- Bone remodeling around stable uncemented titanium stems during the second decade after total hip arthroplasty: a DXA study at 12 and 17 yearsOsteoporosis International, 2010
- Multicentric and prospective study of the Summit cementless stemHIP International, 2010
- Generation of a Danish TTO value set for EQ-5D health statesScandinavian Journal of Public Health, 2009
- The use of the Oxford hip and knee scoresThe Journal of Bone and Joint Surgery. British volume, 2007
- Guidelines for standardization of radiostereometry (RSA) of implantsActa Orthopaedica, 2005
- Wear in uncemented porous and cemented polyethylene sockets: A randomised, Radiostereometric StudyThe Journal of Bone and Joint Surgery. British volume, 1998
- Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses.1994
- Subsidence, Tip, and Hump Micromovements of Noncoated Ribbed Femoral ProsthesesClinical Orthopaedics and Related Research, 1993
- Definition of endoprosthetic loosening: Comparison of arthrography, scintigraphy and roentgen stereophotogrammetry in prosthetic hipsActa Orthopaedica, 1985
- "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.1979