Daan Koppens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daan Koppens has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Torben Bæk Hansen
Department of Orthopedics, University Clinic for Hand, Hip and Knee Surgery, Gødstrup Hospital, Herning; Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
6 shared publications - Maiken Stilling
Aarhus University Hospital
5 shared publications Jesper Dalsgaard
University Clinic for Hand, Hip and Knee Surgery, Gødstrup Hospital Gødstrup Denmark
4 shared publicationsSøren Rytter
Department of Orthopedic Surgery, Aarhus University Hospital, Aarhus N, Denmark
3 shared publications- Emil Toft Petersen
AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
2 shared publications Stig Munk
Department of Orthopedic Surgery, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West Holstebro, Denmark
2 shared publications
Latest Publications
- Open Access
- 2 September 2025
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 96, 656–663
Similar femoral stem fixation but less metaphyseal loss of bone mineral density with a taper-wedge design and diaphyseal bone preservation with a long and round-tapered design: a 5-year randomized RSA and DXA study of 50 patients
Background and purpose: The new Tri-Lock bone -preserving stem with a collarless proximal-coated tapered-wedge design was compared with a classic well-proven collarless proximal-coated long and round-tapered design. Our primary aim was to compare femoral stem fixation (subsidence) of the Tri-Lock stem with the classic Summit stem, and secondarily to compare the change in periprosthetic bone mineral density (BMD) and PROMS between stem groups.Methods: In a patient-blinded randomized controlled trial, 52 patients at mean age 60 (SD 6) received cementless Tri-Lock (n = 26) or Summit (n = 26) femoral stems with a cementless Pinnacle cup, a cross-linked polyethylene liner, and a CoCr head. Patients were followed for 5 years with radiostereometric analysis (RSA), dual-energy X-ray absorptiometry (DXA), and patient-reported outcome measures (PROMs). We measured mean (CI) values of migration and periprosthetic bone mineral density and calculated between group differences.Results: At 2-year follow-up, the mean difference in subsidence was 0.14 mm (95% confidence interval [CI] –0.27 to 0.56) and below the chosen minimal clinically important difference of 0.6 mm. At 5-year follow-up, for the Tri-Lock and Summit stems, the mean subsidence was 0.38 (CI 0.04–0.72) and 0.24 (CI 0.09–0.57), and the mean retroversion was 1.68° (CI 0.80–2.55) and 1.53° (CI 0.68–2.37), respectively. There was initial periprosthetic BMD loss for both stems. At 5-year follow-up, the mean metaphyseal bone loss was minimal for the Tri-Lock stem (zone 1: –2.8% vs –11.5%) while the Summit stem preserved the medial diaphyseal bone better (zone 6: –7.1% vs –13.6%). At the medial stem tip, BMD was increased with the Summit stem (zone 5: +3.4% vs –1.5%). At 5-year follow-up, median EQ5D was 1 in both groups and median Oxford Hip Score was 47 (Tri-Lock) and 45 (Summit) with no statistical significant differences between groups.Conclusion: The Tri-Lock and the Summit stems displayed similar migration until mid-term follow-up. At 3 months both stems had lost metaphyseal periprosthetic bone mineral density (BMD). During the following years, the new design regained more metaphyseal BMD. Contrarily, the long and round-tapered stem design regained or even increased diaphyseal BMD. PROM scores improved beyond the reference level for both groups.
- 2 September 2025
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 96, 656–663
Open AccessSimilar femoral stem fixation but less metaphyseal loss of bone mineral density with a taper-wedge design and diaphyseal bone preservation with a long and round-tapered design: a 5-year randomized RSA and DXA study of 50 patients
Background and purpose: The new Tri-Lock bone -preserving stem with a collarless proximal-coated tapered-wedge design was compared with a classic well-proven collarless proximal-coated long and round-tapered design. Our primary aim was to compare femoral stem fixation (subsidence) of the Tri-Lock stem with the classic Summit stem, and secondarily to compare the change in periprosthetic bone mineral density (BMD) and PROMS between stem groups.Methods: In a patient-blinded randomized controlled trial, 52 patients at mean age 60 (SD 6) received cementless Tri-Lock (n = 26) or Summit (n = 26) femoral stems with a cementless Pinnacle cup, a cross-linked polyethylene liner, and a CoCr head. Patients were followed for 5 years with radiostereometric analysis (RSA), dual-energy X-ray absorptiometry (DXA), and patient-reported outcome measures (PROMs). We measured mean (CI) values of migration and periprosthetic bone mineral density and calculated between group differences.Results: At 2-year follow-up, the mean difference in subsidence was 0.14 mm (95% confidence interval [CI] –0.27 to 0.56) and below the chosen minimal clinically important difference of 0.6 mm. At 5-year follow-up, for the Tri-Lock and Summit stems, the mean subsidence was 0.38 (CI 0.04–0.72) and 0.24 (CI 0.09–0.57), and the mean retroversion was 1.68° (CI 0.80–2.55) and 1.53° (CI 0.68–2.37), respectively. There was initial periprosthetic BMD loss for both stems. At 5-year follow-up, the mean metaphyseal bone loss was minimal for the Tri-Lock stem (zone 1: –2.8% vs –11.5%) while the Summit stem preserved the medial diaphyseal bone better (zone 6: –7.1% vs –13.6%). At the medial stem tip, BMD was increased with the Summit stem (zone 5: +3.4% vs –1.5%). At 5-year follow-up, median EQ5D was 1 in both groups and median Oxford Hip Score was 47 (Tri-Lock) and 45 (Summit) with no statistical significant differences between groups.Conclusion: The Tri-Lock and the Summit stems displayed similar migration until mid-term follow-up. At 3 months both stems had lost metaphyseal periprosthetic bone mineral density (BMD). During the following years, the new design regained more metaphyseal BMD. Contrarily, the long and round-tapered stem design regained or even increased diaphyseal BMD. PROM scores improved beyond the reference level for both groups.
- Open Access
- 7 July 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (11) , 3840-3852
Similar fixation of total knee arthroplasty components with medial congruent and cruciate retaining polyethylene inserts. A randomised double‐blinded controlled radiostereometry trial with 24 months of follow‐up
Purpose: To assess the influence of a higher constraint medial congruent (MC) versus a cruciate retaining (CR) (gold standard) polyethylene insert on the migration of cemented tibial and femoral components of the Persona Total Knee System. High‐constraint inserts may increase forces on components and potentially affect implant migration and long‐term fixation. Methods: A cohort of 66 patients with primary knee osteoarthritis received a cemented Persona total knee arthroplasty and were randomised to either an MC or a CR polyethylene insert. Tibial and femoral component migration was assessed using static radiostereometric analysis, with the first stereo‐radiograph taken supine on the first postoperative day (baseline) and again at 3‐, 12‐, and 24‐month follow‐up. Tibial and femoral component migration was evaluated in six degrees of freedom and as maximum total point motion (MTPM). Results: At the 12‐month follow‐up, the mean difference in tibial component MTPM was 0.04 mm (95% confidence interval [CI]: −0.21 to 0.28). The mean MTPM was 0.81 mm (95% CI: 0.64–0.99) in the MC group and 0.85 mm (95% CI: 0.68–1.03) in the CR group. Signed migrations were similar for the MC and the CR group throughout 24 months of follow‐up ( p > 0.09). At the 12‐month follow‐up, the mean difference in femoral component MTPM was 0.18 mm (95% CI: −0.17 to 0.53). The mean MTPM was 1.08 mm (95% CI: 0.83–1.32) in the MC group and 1.26 mm (95% CI: 1.01–1.51) in the CR group. The femoral components with MC insert had 0.18 mm (95% CI: 0.03–0.32) and 0.20 mm (95% CI: 0.01–0.39) more lateral migration at 3‐ and 12‐month follow‐up, respectively. At the 24‐month follow‐up, there was no statistically significant differences in migration for either translations, rotations or MTPM. Conclusions: Both tibial and femoral components had similar and acceptable fixation regardless of the type of polyethylene insert. Level of Evidence: Level I.
- 7 July 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (11) , 3840-3852
Open AccessSimilar fixation of total knee arthroplasty components with medial congruent and cruciate retaining polyethylene inserts. A randomised double‐blinded controlled radiostereometry trial with 24 months of follow‐up
Purpose: To assess the influence of a higher constraint medial congruent (MC) versus a cruciate retaining (CR) (gold standard) polyethylene insert on the migration of cemented tibial and femoral components of the Persona Total Knee System. High‐constraint inserts may increase forces on components and potentially affect implant migration and long‐term fixation. Methods: A cohort of 66 patients with primary knee osteoarthritis received a cemented Persona total knee arthroplasty and were randomised to either an MC or a CR polyethylene insert. Tibial and femoral component migration was assessed using static radiostereometric analysis, with the first stereo‐radiograph taken supine on the first postoperative day (baseline) and again at 3‐, 12‐, and 24‐month follow‐up. Tibial and femoral component migration was evaluated in six degrees of freedom and as maximum total point motion (MTPM). Results: At the 12‐month follow‐up, the mean difference in tibial component MTPM was 0.04 mm (95% confidence interval [CI]: −0.21 to 0.28). The mean MTPM was 0.81 mm (95% CI: 0.64–0.99) in the MC group and 0.85 mm (95% CI: 0.68–1.03) in the CR group. Signed migrations were similar for the MC and the CR group throughout 24 months of follow‐up ( p > 0.09). At the 12‐month follow‐up, the mean difference in femoral component MTPM was 0.18 mm (95% CI: −0.17 to 0.53). The mean MTPM was 1.08 mm (95% CI: 0.83–1.32) in the MC group and 1.26 mm (95% CI: 1.01–1.51) in the CR group. The femoral components with MC insert had 0.18 mm (95% CI: 0.03–0.32) and 0.20 mm (95% CI: 0.01–0.39) more lateral migration at 3‐ and 12‐month follow‐up, respectively. At the 24‐month follow‐up, there was no statistically significant differences in migration for either translations, rotations or MTPM. Conclusions: Both tibial and femoral components had similar and acceptable fixation regardless of the type of polyethylene insert. Level of Evidence: Level I.
- Open Access
- 1 February 2022
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 30 (2) , 249-259
Patients with knee osteoarthritis can be divided into subgroups based on tibiofemoral joint kinematics of gait – an exploratory and dynamic radiostereometric study
- 1 February 2022
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 30 (2) , 249-259
Open AccessPatients with knee osteoarthritis can be divided into subgroups based on tibiofemoral joint kinematics of gait – an exploratory and dynamic radiostereometric study
- Open Access
- 11 July 2019
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 90 (6) , 575-581
Equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up
Background and purpose - Differences in stress distribution in a mobile-bearing and fixed-bearing unicompartmental knee arthroplasty (UKA) design might lead to a difference in fixation of the tibial component. We compared tibial component migration of a mobile-bearing (MB) UKA and a fixed-bearing (FB) UKA using radiostereometric analysis.Patients and methods - In a randomized, patient-blinded clinical trial 62 patients received either the MB Oxford UKA or the FB Sigma UKA. The patients were followed for 24 months with radiostereometric analysis. Clinical outcome was assessed with Oxford Knee Score (OKS), RAND-36 and leg extension power.Results - Migration of the tibial components was similar between groups throughout follow-up. At 12 months, MTPM of the tibial component was 0.44 mm (95% CI 0.34-0.55) for the MB group and 0.40 mm (CI 0.31-0.50) for the FB group. Between 12 and 24 months, the tibial components migrated with a median MTPM increase of 0.03 mm (CI -0.02 to 0.08) in the MB group and 0.03 mm (CI -0.02 to 0.07) in the FB group. Continuous migration of the tibial component was found for 1 MB UKA and 2 FB UKAs. Both groups showed similar and clinically relevant improvement in clinical outcome.Interpretation - MB and FB tibial components had similar good fixation and clinical improvement until 2 years. Based on this study, a low 5- to 10-year revision rate can be expected for both implants.
- 11 July 2019
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 90 (6) , 575-581
Open AccessEqual tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up
Background and purpose - Differences in stress distribution in a mobile-bearing and fixed-bearing unicompartmental knee arthroplasty (UKA) design might lead to a difference in fixation of the tibial component. We compared tibial component migration of a mobile-bearing (MB) UKA and a fixed-bearing (FB) UKA using radiostereometric analysis.Patients and methods - In a randomized, patient-blinded clinical trial 62 patients received either the MB Oxford UKA or the FB Sigma UKA. The patients were followed for 24 months with radiostereometric analysis. Clinical outcome was assessed with Oxford Knee Score (OKS), RAND-36 and leg extension power.Results - Migration of the tibial components was similar between groups throughout follow-up. At 12 months, MTPM of the tibial component was 0.44 mm (95% CI 0.34-0.55) for the MB group and 0.40 mm (CI 0.31-0.50) for the FB group. Between 12 and 24 months, the tibial components migrated with a median MTPM increase of 0.03 mm (CI -0.02 to 0.08) in the MB group and 0.03 mm (CI -0.02 to 0.07) in the FB group. Continuous migration of the tibial component was found for 1 MB UKA and 2 FB UKAs. Both groups showed similar and clinically relevant improvement in clinical outcome.Interpretation - MB and FB tibial components had similar good fixation and clinical improvement until 2 years. Based on this study, a low 5- to 10-year revision rate can be expected for both implants.
- 19 November 2018
- Published by Springer Nature in Skeletal Radiology
- Vol. 48 (7) , 1069-1077
The lateral joint space width can be measured reliably with Telos valgus stress radiography in medial knee osteoarthritis
Objective To examine the reproducibility of valgus stress radiographs with the Telos stress device for assessment of lateral compartment degenerative changes in patients with medial osteoarthritis of the knee. Materials and methods A prospective reliability study was performed. Seventy-nine patients (80 knees) were included, and standardized valgus stress radiographs were obtained using the Telos stress device. Osteophytes and joint space narrowing (JSN) were graded using the OARSI (Osteoarthritis Research Society International) classification, and the joint space width (JSW) was measured in millimeters. Reproducibility was determined as intra-and inter-rater reliability and test–retest reliability. Weighted kappa was used to determine the reliability of osteophyte and JSN grading, and the intra-class correlation coefficient for JSW. Results Grading of osteophytes had an intra- and inter-rater reliability ranging from 0.40 to 0.83 on the medial side and ranging from 0.39 to 0.87 on the lateral side. Grading of medial JSN had an intra- and inter-rater reliability ranging from 0.62 to 0.84, and grading of lateral JSN had an intra- and inter-rater reliability ranging from 0.32 to 0.65. Intra- and inter-rater reliability of JSW ranged from 0.84 to 0.98 on the medial side, and from 0.59 to 0.89 on the lateral side. Test–retest reliability of JSW of the medial and lateral side ranged from 0.69 to 0.92. Conclusions Standardized valgus stress radiographs taken with the Telos stress device are a reliable supplement in the assessment of medial OA of the knee. Evaluation of the lateral compartment on valgus stress radiographs is most reliable with measurement of the lateral JSW.
- 19 November 2018
- Published by Springer Nature in Skeletal Radiology
- Vol. 48 (7) , 1069-1077
The lateral joint space width can be measured reliably with Telos valgus stress radiography in medial knee osteoarthritis
Objective To examine the reproducibility of valgus stress radiographs with the Telos stress device for assessment of lateral compartment degenerative changes in patients with medial osteoarthritis of the knee. Materials and methods A prospective reliability study was performed. Seventy-nine patients (80 knees) were included, and standardized valgus stress radiographs were obtained using the Telos stress device. Osteophytes and joint space narrowing (JSN) were graded using the OARSI (Osteoarthritis Research Society International) classification, and the joint space width (JSW) was measured in millimeters. Reproducibility was determined as intra-and inter-rater reliability and test–retest reliability. Weighted kappa was used to determine the reliability of osteophyte and JSN grading, and the intra-class correlation coefficient for JSW. Results Grading of osteophytes had an intra- and inter-rater reliability ranging from 0.40 to 0.83 on the medial side and ranging from 0.39 to 0.87 on the lateral side. Grading of medial JSN had an intra- and inter-rater reliability ranging from 0.62 to 0.84, and grading of lateral JSN had an intra- and inter-rater reliability ranging from 0.32 to 0.65. Intra- and inter-rater reliability of JSW ranged from 0.84 to 0.98 on the medial side, and from 0.59 to 0.89 on the lateral side. Test–retest reliability of JSW of the medial and lateral side ranged from 0.69 to 0.92. Conclusions Standardized valgus stress radiographs taken with the Telos stress device are a reliable supplement in the assessment of medial OA of the knee. Evaluation of the lateral compartment on valgus stress radiographs is most reliable with measurement of the lateral JSW.
- 16 November 2017
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 26 (6) , 1776-1785
Low implant migration of the SIGMA® medial unicompartmental knee arthroplasty
The purpose of this study was to evaluate implant migration of the fixed-bearing Sigma® medial unicompartmental knee arthroplasty (UKA). UKA is a regularly used treatment for patients with medial osteoarthritis (OA) of the knee. UKA has a higher revision rate than total knee arthroplasty. Implant migration can be used as a predictor of implant loosening.
- 16 November 2017
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 26 (6) , 1776-1785
Low implant migration of the SIGMA® medial unicompartmental knee arthroplasty
The purpose of this study was to evaluate implant migration of the fixed-bearing Sigma® medial unicompartmental knee arthroplasty (UKA). UKA is a regularly used treatment for patients with medial osteoarthritis (OA) of the knee. UKA has a higher revision rate than total knee arthroplasty. Implant migration can be used as a predictor of implant loosening.
- 1 November 2008
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 89 (11) , 2080-2085
Power-Assisted Wheels Ease Energy Costs and Perceptual Responses to Wheelchair Propulsion in Persons With Shoulder Pain and Spinal Cord Injury
- 1 November 2008
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 89 (11) , 2080-2085
Power-Assisted Wheels Ease Energy Costs and Perceptual Responses to Wheelchair Propulsion in Persons With Shoulder Pain and Spinal Cord Injury