    Similar femoral stem fixation but less metaphyseal loss of bone mineral density with a taper-wedge design and diaphyseal bone preservation with a long and round-tapered design: a 5-year randomized RSA and DXA study of 50 patients

    by Peter Bo Jørgensen, Morten Homilius, Daan Koppens, Torben Bæk Hansen, Maiken Stilling

    Background and purpose: The new Tri-Lock bone -preserving stem with a collarless proximal-coated tapered-wedge design was compared with a classic well-proven collarless proximal-coated long and round-tapered design. Our primary aim was to compare femoral stem fixation (subsidence) of the Tri-Lock stem with the classic Summit stem, and secondarily to compare the change in periprosthetic bone mineral density (BMD) and PROMS between stem groups.Methods: In a patient-blinded randomized controlled trial, 52 patients at mean age 60 (SD 6) received cementless Tri-Lock (n = 26) or Summit (n = 26) femoral stems with a cementless Pinnacle cup, a cross-linked polyethylene liner, and a CoCr head. Patients were followed for 5 years with radiostereometric analysis (RSA), dual-energy X-ray absorptiometry (DXA), and patient-reported outcome measures (PROMs). We measured mean (CI) values of migration and periprosthetic bone mineral density and calculated between group differences.Results: At 2-year follow-up, the mean difference in subsidence was 0.14 mm (95% confidence interval [CI] –0.27 to 0.56) and below the chosen minimal clinically important difference of 0.6 mm. At 5-year follow-up, for the Tri-Lock and Summit stems, the mean subsidence was 0.38 (CI 0.04–0.72) and 0.24 (CI 0.09–0.57), and the mean retroversion was 1.68° (CI 0.80–2.55) and 1.53° (CI 0.68–2.37), respectively. There was initial periprosthetic BMD loss for both stems. At 5-year follow-up, the mean metaphyseal bone loss was minimal for the Tri-Lock stem (zone 1: –2.8% vs –11.5%) while the Summit stem preserved the medial diaphyseal bone better (zone 6: –7.1% vs –13.6%). At the medial stem tip, BMD was increased with the Summit stem (zone 5: +3.4% vs –1.5%). At 5-year follow-up, median EQ5D was 1 in both groups and median Oxford Hip Score was 47 (Tri-Lock) and 45 (Summit) with no statistical significant differences between groups.Conclusion: The Tri-Lock and the Summit stems displayed similar migration until mid-term follow-up. At 3 months both stems had lost metaphyseal periprosthetic bone mineral density (BMD). During the following years, the new design regained more metaphyseal BMD. Contrarily, the long and round-tapered stem design regained or even increased diaphyseal BMD. PROM scores improved beyond the reference level for both groups.


  • Open Access

    Less early subsidence of cemented Exeter short stems compared with cemented Exeter standard stems in Dorr type A femurs

    by Peter B. Jørgensen, Stig S. Jakobsen, Dovydas Vainorius, Morten Homilius, Torben B. Hansen, Maiken Stilling

    Aims: The Exeter short stem was designed for patients with Dorr type A femora and short-term results are promising. The aim of this study was to evaluate the minimum five-year stem migration pattern of Exeter short stems in comparison with Exeter standard stems.Methods: In this case-control study, 25 patients (22 female) at mean age of 78 years (70 to 89) received cemented Exeter short stem (case group). Cases were selected based on Dorr type A femora and matched first by Dorr type A and then age to a control cohort of 21 patients (11 female) at mean age of 74 years (70 to 89) who received with cemented Exeter standard stems (control group). Preoperatively, all patients had primary hip osteoarthritis and no osteoporosis as confirmed by dual X-ray absorptiometry scanning. Patients were followed with radiostereometry for evaluation of stem migration (primary endpoint), evaluation of cement quality, and Oxford Hip Score. Measurements were taken preoperatively, and at three, 12, and 24 months and a minimum five-year follow-up.Results: At three months, subsidence of the short stem -0.87 mm (95% confidence interval (CI) -1.07 to -0.67) was lower compared to the standard stem -1.59 mm (95% CI -1.82 to -1.36; p < 0.001). Both stems continued a similar pattern of subsidence until five-year follow-up. At five-year follow-up, the short stem had subsided mean -1.67 mm (95% CI -1.98 to -1.36) compared to mean -2.67 mm (95% CI -3.03 to -2.32) for the standard stem (p < 0.001). Subsidence was not influenced by preoperative bone quality (osteopenia vs normal) or cement mantle thickness.Conclusion: The standard Exeter stem had more early subsidence compared with the short Exeter stem in patients with Dorr type A femora, but thereafter a similar migration pattern of subsidence until minimum five years follow-up. Both the standard and the short Exeter stems subside. The standard stem subsides more compared to the short stem in Dorr type A femurs. Subsidence of the Exeter stems was not affected by cement mantle thickness.Cite this article: Bone Jt Open 2023;4(7):507–515.


  • Five-year polyethylene cup migration and PE wear of the Anatomic Dual Mobility acetabular construct

    by Peter Bo Jørgensen, Bart L. Kaptein, Kjeld Søballe, Stig S. Jakobsen, Maiken Stilling

    Introduction Dual mobility implants have been successful in reducing postoperative hip dislocation but mid-term results of cup migration and polyethylene wear are missing in the literature. Therefore, we measured migration and wear at 5-year follow-up using radiostereometric analysis (RSA). Materials and methods A cohort of 44 patients (mean age 73, 36 female) with heterogeneous indications for hip arthroplasty but all with a high risk of hip dislocation received total hip replacement (THA) with The Anatomic Dual Mobility X3 monoblock acetabular construct and a highly crosslinked polyethylene liner. RSA images and Oxford Hip Scores were obtained perioperatively and 1, 2, and 5 years postoperatively. Cup migration and polyethylene wear were calculated using RSA. Results Mean 2-year proximal cup translation was 0.26 mm (95% CI 0.17; 0.36). Proximal cup translation was stable from 1- to 5-year follow-up. Mean 2-year cup inclination (z-rotation) was 0.23° (95% CI − 0.22; 0.68) and was greater in patients with osteoporosis compared to patients without osteoporosis (p = 0.04). Using 1-year follow-up as baseline, the 3D polyethylene wear rate was 0.07 mm/year (0.05; 0.10). Oxford hip scores improved 19 (95% CI 14; 24) points from mean 21 (range 4; 39) at baseline, to 40 (9; 48) 2 years postoperatively. There were no progressive radiolucent lines > 1 mm. There was 1 revision for offset correction. Conclusions Anatomic Dual Mobility monoblock cups were well-fixed, the polyethylene wear rate was low, and the clinical outcomes were good until 5-year follow-up suggesting good implant survival in patients of different age groups and with heterogeneous indications for THA.


  • Open Access

    Cemented and cementless dual mobility cups show similar fixation, low polyethylene wear, and low serum cobalt-chromium in elderly patients: a randomized radiostereometry study with 6 years’ follow-up

    by Peter Bo Jørgensen, Steffan Tabori-Jensen, Inger Mechlenburg, Morten Homilius, Torben Bæk Hansen, Maiken Stilling

    Background and purpose: Dual mobility (DM) articulation total hip arthroplasty (THA) is used increasingly to reduce dislocation risk. We investigated cup fixation, polyethylene (PE) wear, serum chromium and cobalt ions, and their correlation to physical activity in patients with DM cups at 6-year follow-up.Patients and methods: In a patient-blinded RCT, 60 patients with hip osteoarthritis at a median age of 74 years (70–82) were randomly allocated to cemented (n = 30) or cementless hydroxyapatite-coated (n = 30) fixation of Avantage DM THA with a highly-crosslinked vitamin-E PE liner. Cup migration and PE wear were measured with radiostereometric analysis (RSA), chromium and cobalt ions were measured in serum, and physical activity was measured with accelerometers.Results: At 6-year follow-up, proximal cup migration was similar: 0.14 mm (95% CI 0.01–0.28) for cemented cups and 0.21 mm (0.02–0.39) for cementless cups. The PE wear rate from 1- to 6-year follow-up was also similar: 0.06 mm/year (0.04–0.09) for cemented cups and 0.07 mm/year (0.04–0.11) for cementless cups. Serum metal ion levels were undetectable or very low. Physical activity was mainly low intensity and did not correlate to PE wear rate or cup migration.Conclusion: Cemented and cementless DM cups with highly crosslinked vitamin-E infused liners have similar cup migration and PE wear when used for primary THA surgery.


  • Radiostereometric analysis: comparison of radiation dose and precision in digital and computed radiography

    by Peter Bo Jørgensen, Nicolai Krag-Nielsen, Lars Lindgren, Rikke Margrethe Staghøj Mørup, Bart Kaptein, Maiken Stilling

    Background Radiostereometric Analysis (RSA) is used to measure fixation of joint prosthesis. This study compared radiation dose and image quality of a digital radiography (DR) RSA system and a computed radiography (CR) RSA system in a clinical setting. Methods RSA recordings of 24 hips and shoulders were analyzed. We compared two systems: (1) Arcoma T0 with ST-VI image plates and Profect CR-IR 363 reader to (2) AdoraRSA with CXDI-70C wireless DR detectors in a clinical uniplanar RSA set-up with a ± 20 degrees tube angulation and 35 cm × 43 cm detectors. Effective dose was calculated using dedicated software. Image quality was evaluated using calibration errors as calculated by the RSA software. Results The mean dose for hips was 0.14 (SD 0.04) mSv in the CR system and 0.05 (SD 0.02) mSv in the DR system. The mean dose for shoulders was 0.16 (SD 0.07) mSv in the CR system and 0.09 (SD 0.03) mSv in the DR system. Radiation dose was 64% (p < 0.001) and 43% (p = 0.03) lower in the DR system compared with the CR system for hip and shoulder RSA, respectively. Image quality was better for the DR system with 60–80% less calibration errors compared to the CR system. Conclusion Owing to highly efficient detectors and added filtration at the x-ray tubes, the DR system considerably reduced radiation dose compared with the CR system without compromising image quality. Based on the findings in this study, we recommend replacing CR RSA systems with DR RSA systems. Registration Patients were selected from clinical studies performed on the two systems and approved by the local ethics committee [20060165, M-20100112, M-20070082, M-20110224, and 20070258] and registered with ClinicalTrials.gov [NCT00408096, NCT01289834, NCT00913679, NCT02311179, and NCT00679120].


  • Open Access

    Larger 5-year migration but similar polyethylene wear of cementless hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) coating compared with porous plasma-spray titanium: a randomized 5-year RSA study

    by Sebastian Breddam Mosegaard, Peter Bo Jørgensen, Stig Storgaard Jakobsen, Henrik Daugaard, Kjeld Søballe, Maiken Stilling

    Background and purpose: BoneMaster (BM) is a thin electrochemically applied hydroxyapatite (HA) implant coating marketed with expectations of improved osseointegration properties but less polyethylene (PE) wear. We compared the midterm cup migration and PE wear of cementless porous-coated hemispherical cups with and without BM.Patients and methods: In this patient-blinded, randomized controlled trial, 53 patients with a mean age of 64 years (55–75) received total hip arthroplasty with a porous-coated (P) or porous and BoneMaster (PBM) coated Exceed cup and ArCom E1 infused PE. Patients were followed with RSA, Hip Osteoarthritis Outcome Score (HOOS), and Euro-Qol-5-3L (EQ-5D) at 3 and 6 months, and 1-, 2-, and 5-yearfollow-up.Results: At 5-year follow-up, total translation and maximum total point motion was 0.28 mm (95% CI 0.08; 0.47) and 0.52 mm (CI 0.12; 0.93) higher in the PBM group than in the P group. PE wear was comparable between PBM and P cups, and 2D wear rate from 1-year follow-up to last follow-up was 0.03 mm (CI 0.02–0.03). The 5-year anterior translation was 0.05 mm (CI –0.10 to 0.21) in the normal BMD group and 0.40 mm (CI 0.22–0.57) in the osteopenia group.Interpretation: At 5-year follow-up, Exceed cups in the PBM group migrated more than in the P group but the PE wear rate was low and similar. This study does not indicate any advantage of additional BoneMaster coating compared with porous coating alone on cementless hemispherical cups with regards to migration, polyethylene wear, and clinical outcomes.


  • Open Access

    Polyethylene liner motion in dual-mobility hip prostheses: static and dynamic radiostereometry in 16 patients 1 year after operation

    by Peter Bo Jørgensen, Bart L Kaptein, Kjeld Søballe, Stig S Jakobsen, Maiken Stilling

    Background and purpose: Dual-mobility hip arthroplasty utilizes a freely rotating polyethylene acetabular liner to protect against dislocation. As liner motion has not been confirmed in vivo, we undertook this using dynamic radiostereometry (RSA). Patients and methods: 6 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient-reported outcome measures were obtained postoperatively and at 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER–FADIR), to end-range and at 45° hip flexion. Liner and neck movements were described as anteversion, inclination, and rotation. Results: Liner movement during modified FABER–FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5–20), inclination 6° (2–12), and rotation 11° (5–48) relative to the cup. Median absolute change in the resulting liner/neck angle (small articulation) was 28° (12–46) and in liner/cup angle (larger articulation) was 6° (4–21). Static RSA showed changes in median liner anteversion from 7° (−12 to 23) postoperatively to 10° (−3 to 16) at 1-year follow-up and inclination from 42° (35–66) postoperatively to 59° (46–80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p = 0.01). Interpretation: The polyethylene liner moves over time. 1 year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner.


  • Migration pattern of cemented Exeter short stem in Dorr type A femurs. A prospective radiostereometry study with 2-year follow-up

    by Tobias Dahl Vind, Peter Bo Jørgensen, Dovydas Vainorius, Stig Storgaard Jakobsen, Kjeld Søballe, Maiken Stilling

    Introduction The Exeter short stem (ESS) is 25 mm shorter than the standard length v40 Exeter stem (Stryker) and intended for a narrow femoral diaphysis. The purpose of the study was to evaluate the migration pattern of the cemented ESS. Material and method In a prospective single-center cohort study, 23 patients (21 female) mean age 78 (range 70–89) with hip osteoarthritis and Dorr Type A femurs were included. Preoperative DXA was used to group patients into normal (> − 1) and low (< − 1) T-score. Components were the collarless polished double-tapered Exeter short stem type N°1 L125. Patients were followed for 2 years with model-based RSA (stem migration), regular hip radiographs (stem position and cementation quality), Oxford Hip Score (OHS) and VAS pain. Results At 2-year follow-up, the stems subsided 1.48 mm (CI 95% 1.69; 1.26) and retroverted 0.45° (CI 95% 0.01; 0.88). From 12 to 24 months, stem subsidence was 0.18 mm (CI 95% 0.1; 0.25) (p = 0.001) and retroversion was − 0.04° (CI 95% − 0.27; 0.18) (p = 0.70). T-score and stem subsidence correlated (rho = 0.48; p = 0.025) and patients with normal T-score (n = 7) had 0.42 mm (CI 95% − 0.01; 0.85) less subsidence as compared to patients with low T-score (n = 15) (p = 0.054). Stems in varus position (n = 9) subsided 1.7 mm (CI 95% 1.35; 2.05) compared to 1.33 mm (CI 95% 1.05; 1.60) for stems in neutral position (n = 13) (p = 0.07). Postoperative cementation quality did not influence 2-year stem migration. OHS improved to 40.7 (CI 95% 36.8; 44.7) and VAS pain at rest and activity decreased to 5 mm and 10 mm, respectively (p < 0.001). Conclusion The 2-year migration pattern of the cemented ESS was similar to reports for the cemented standard length Exeter stem. Low preoperative T-score and varus stem-position showed a tendency for higher stem migration and should be studied as risk factors for failure in larger studies of cemented polished stems.


  • Open Access

    Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study

    by Peter Bo Jørgensen, Bart L. Kaptein, Kjeld Søballe, Stig S. Jakobsen, Maiken Stilling

    Background: Investigation of polyethylene liner movement in total hip arthroplasty requires bead-marking for radiographic visibility of the liner. However, occlusion of markers poses a challenge for marker registration in radiographs. Methods: The polyethylene of a dual mobility acetabular system was marked with twelve 1-mm tantalum markers (four groups of three markers) using a custom-made drill guide. Liner motion in a phantom and a patient was investigated with dynamic radiostereometry analysis (dRSA) at 1-year follow-up and static radiostereometry analysis (sRSA) postoperatively and at 1- and 2-year follow-up. A combined marker configuration (CMC) model was calculated from the registered positions of the liner markers and the femoral head in several images. Furthermore, the CMC model and the theoretic marker positions from computer-assisted models of the drill guide were combined in a hybrid model. Results: The CMC model included eleven markers in the phantom and nine markers in the patient, which was sufficient for dRSA. Liner movement in the phantom followed liner contact with the femoral neck, while liner movement in the patient was independent. The hybrid model was necessary to determine liner orientation in sRSA recordings, which clearly changed from postoperative to 1- and 2-year follow-up even though the patient was positioned similarly. Conclusion: Polyethylene liner motion in dual mobility hip prosthesis can be assessed with CMC models in dRSA recordings. In sRSA, the liner position between follow-ups is unpredictable and analysis requires inclusion of all markers in the model, accomplished with a hybrid marker model. Trial registration: ClinicalTrials.gov [NCT02301182], 25 October 2015.


  • Similar patient positioning: A key factor in follow-up studies when using model-based radiostereometric analysis of the hip

    by L. Lindgren, P.B. Jørgensen, R.M.S. Mørup, M. Jensen, L. Rømer, B. Kaptein, M. Stilling