Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty: A sonographic and radiographic study of 39 patients
Open Access
- 1 January 2008
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 79 (4) , 489-493
Abstract
The role of synovitis and high fluid pressure in the loosening process after total hip arthroplasty has gained increasing attention. We investigated the correlation between head size, polyethylene wear, and capsular distention. We analyzed 39 unrevised, radiographically stable hips that had been operated with 28 or 32 mm femoral heads 10 years earlier because of osteoarthritis. We evaluated radiographic signs of loosening, linear and volumetric polyethylene wear, body mass index, activity level, and age. Sonographic examination was performed to measure capsular distance i.e. the distance between the prosthetic femoral neck and the anterior capsule. Linear wear was 0.09 mm/year and 0.18 mm/year in the 28 mm and 32 mm groups, respectively (p < 0.001). The volumetric wear was 51 mm(3)/year and 136 mm(3)/year (p < 0.001) and the capsular distance was 13 mm and 17 mm, respectively (p < 0.001). There was a correlation between linear wear (r = 0.54), volumetric wear (r = 0.62), and capsular distance (p < 0.001). Wear was greater for the larger femoral head and was correlated to capsular distension.Keywords
This publication has 27 references indexed in Scilit:
- Estimation of the wear volume after total hip replacement: A simple access to geometrical conceptsMedical Engineering & Physics, 2007
- Femoral head diameter affects the revision rate in total hip arthroplasty: An analysis of 1,720 hip replacements with 9–21 years of follow-upActa Orthopaedica, 2006
- Increase in early polyethylene wear after sterilization with ethylene oxideRadiostereometric analyses of 201 total hipsActa Orthopaedica, 2003
- Polyethylene wear in prosthetic hips with loose componentsThe Journal of Arthroplasty, 2003
- Wear and osteolysis in total joint replacementsActa Orthopaedica, 1998
- Benign Cellular Responses in Rats to Different Wear Particles in Intra-Articular and Intramedullary EnvironmentsThe Journal of Bone and Joint Surgery. British volume, 1997
- Polyethylene wear in Scanhip® arthroplasty with a 22 or 32 mm head:62 matched patients followed for 7-9 yearsActa Orthopaedica, 1996
- Implant stability, histology, RSA and wear–more critical questions are needed: A view pointActa Orthopaedica, 1994
- Bone resorption activity of particulate-stimulated macrophagesJournal of Bone and Mineral Research, 1993
- Low-vs high-viscosity cement in hip arthroplasty: No radiographic difference in 226 arthrosis cases followed for 5 yearsActa Orthopaedica, 1993