Clinical value of smear review of flagged samples analyzed with the Sysmex XN hematology analyzer
Open Access
- 2 September 2024
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 63 (3) , 636-644
Abstract
Objectives: A smear review is typically made in flagged differential counts performed with hematology analyzers although the clinical value of such reviews is uncertain. Therefore, we evaluated the differences in differential counts between Sysmex XN-9000 and a smear review in flagged samples. Furthermore, the clinical value of blasts identified was investigated. Methods: Data on all differential counts performed in a two-year period were identified at two laboratories. In patients with blasts, the electronic health record was reviewed. Agreement between automated and manual differential counts was evaluated by Bland-Altman plots. Concordance between the two methods categorized according to reference intervals was evaluated and adjusted for irrelevant non-concordance caused by random analytical error. Results: In total, 5,500 flagged differential counts were identified from 4,092 patients. A good agreement between the automated and manual differential count was found for all cell types (−0.480 × 10 9 /L to 0.297 × 10 9 /L). The concordance between the two methods was excellent for all cell types, except for monocytes (82 %) where the automated estimates were higher than the manual in 19 % of samples. Blasts were identified in 241 (1 %) of smear reviews. Acute leukemia was diagnosed in 13 (5 %) patients, and only in one patient contributed the detection of blasts to the suspicion of acute leukemia. Conclusions: Our findings indicate that routine smear review of all flagged samples do not contribute with additional, significant information. After local validation and dialogue with clinical departments, such reviews may potentially be omitted to increase cost-effectiveness and reduce turn-around-time.Keywords
This publication has 19 references indexed in Scilit:
- Chronic myelomonocytic leukemia: 2024 update on diagnosis, risk stratification and managementAmerican Journal of Hematology, 2024
- Reference intervals for platelet large cell ratio, platelet distribution width, plateletcrit and standard haematological parameters determined on the Sysmex XN-10 in a cohort of 30,917 Danish blood donorsScandinavian Journal of Clinical and Laboratory Investigation, 2022
- Complex biological patterns of hematology parameters in childhood necessitating age‐ and sex‐specific reference intervals for evidence‐based clinical interpretationInternational Journal of Laboratory Hematology, 2020
- Blast flagging of the Sysmex XN‐10 hematology analyzer with supervised cell image analysis: Impact on quality parametersInternational Journal of Laboratory Hematology, 2019
- Evaluation of the detection of blasts by Sysmex hematology instruments, CellaVision DM96, and manual microscopy using flow cytometry as the confirmatory methodInternational Journal of Laboratory Hematology, 2019
- Preoperative Laboratory TestingAnesthesiology Clinics, 2018
- Evaluation and comparison of automated hematology analyzer, flow cytometry, and digital morphology analyzer for monocyte countingInternational Journal of Laboratory Hematology, 2018
- Performance evaluation of the new measurement channels on the automated Sysmex XN-9000 hematology analyzerClinical Biochemistry, 2018
- ICSH guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte countingInternational Journal of Laboratory Hematology, 2014
- Peripheral blood film review: the demise of the eyecount leukocyte differentialClinics In Laboratory Medicine, 2002