BGBingbing Gao

Bingbing Gao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bingbing Gao has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fractional Anisotropy is a More Sensitive Diagnostic Biomarker Than Mean Kurtosis for Patients with Parkinson Disease with Cognitive Dysfunction: A Diffusional Kurtosis Map Tract-Based Spatial Statistics Study

    by Bingbing Gao, Mingrui Qu, Yuhan Jiang, Wanyao Li, Man Wang, Chenhui Pei, Dandan Zheng, Chao Yang, Yanwei Miao

    BACKGROUND AND PURPOSE: There is heterogeneity of white matter damage in Parkinson9s disease patients with different cognitive states. Our aim was to find sensitive diffusional kurtosis imaging biomarkers to differentiate the white matter damage pattern of mild cognitive impairment and dementia. MATERIALS AND METHODS: Nineteen patients with Parkinson disease with mild cognitive impairment and 18 patients with Parkinson disease with dementia were prospectively enrolled. All participants underwent MR examination with 3D-T1-weighted image and diffusional kurtosis imaging sequences. Demographic data were compared between the 2 groups. Voxelwise statistical analyses of diffusional kurtosis imaging parameters were performed using tract-based spatial statistics. The receiver operator characteristic curve of significantly different metrics was graphed. The correlation of significantly different metrics with global cognitive status was analyzed. RESULTS: Compared with the Parkinson disease with mild cognitive impairment group, the fractional anisotropy and mean kurtosis values decreased in 4 independent clusters in the forceps minor, forceps major, inferior fronto-occipital fasciculus, and the inferior and superior longitudinal fasciculus in patients with Parkinson disease with dementia; the mean diffusivity decreased in 1 cluster in the forceps minor. The fractional anisotropy value in the inferior fronto-occipital fasciculus and inferior longitudinal fasciculus would be the diffusional kurtosis imaging marker for the differential diagnosis of Parkinson disease with mild cognitive impairment and patients with Parkinson disease with dementia, with the best diagnostic efficiency of 0.853. The fractional anisotropy values in the forceps minor (β = 84.20, P < .001) and years of education (β = 0.38, P = .014) were positively correlated with the Montreal Cognitive Assessment. CONCLUSIONS: The diffusional kurtosis imaging–derived fractional anisotropy and mean kurtosis can detect the different white matter damage patterns of Parkinson disease with mild cognitive impairment and Parkinson disease with dementia. Fractional anisotropy is more sensitive than mean kurtosis in the differential diagnosis; fractional anisotropy derived from diffusional kurtosis imaging could become a promising imaging marker for the differential diagnosis of Parkinson disease with mild cognitive impairment and Parkinson disease with dementia.


  • Acceleration of Brain Susceptibility-Weighted Imaging with Compressed Sensitivity Encoding: A Prospective Multicenter Study

    by J. Ding, Y. Duan, M. Wang, Y. Yuan, Z. Zhuo, L. Gan, Q. Song, B. Gao, L. Yang, H. Liu, et al.

    BACKGROUND AND PURPOSE: While three-dimensional susceptibility-weighted imaging has been widely suggested for intracranial vessel imaging, hemorrhage detection, and other neuro-diseases, its relatively long scan time has necessitated the clinical verification of recent progresses of fast imaging techniques. Our aim was to evaluate the effectiveness of brain SWI accelerated by compressed sensitivity encoding to identify the optimal acceleration factors for clinical practice. MATERIALS AND METHODS: Ninety-nine subjects, prospectively enrolled from 5 centers, underwent 8 brain SWI sequences: 5 different folds of compressed sensitivity encoding acceleration (CS2, CS4, CS6, CS8, and CS10), 2 different folds of sensitivity encoding acceleration (SF2 and SF4), and 1 without acceleration. Images were assessed quantitatively on both the SNR of the red nucleus and its contrast ratio to the CSF and, subjectively, with scoring on overall image quality; visibility of the substantia nigra–red nucleus, basilar artery, and internal cerebral vein; and diagnostic confidence of the cerebral microbleeds and other intracranial diseases. RESULTS: Compressed sensitivity encoding showed a promising ability to reduce the acquisition time (from 202 to 41 seconds) of SWI while increasing the acceleration factor from 2 to 10, though at the cost of decreasing the SNR, contrast ratio, and the scores of visual assessments. The visibility of the substantia nigra–red nucleus and internal cerebral vein became unacceptable in CS6 to CS10. The basilar artery was well-distinguished, and diseases including cerebral microbleeds, cavernous angiomas, intracranial gliomas, venous malformations, and subacute hemorrhage were well-diagnosed in all compressed sensitivity encoding sequences. CONCLUSIONS: Compressed sensitivity encoding factor 4 is recommended in routine practice. Compressed sensitivity encoding factor 10 is potentially a fast surrogate for distinguishing the basilar artery and detecting susceptibility-related abnormalities (eg, cerebral microbleeds, cavernous angiomas, gliomas, and venous malformation) at the sacrifice of visualization of the substantia nigra–red nucleus and internal cerebral vein.


  • Open Access

    Iron deposits in the red nucleus at long-term follow-up after hypertrophic olivary degeneration

    by Yangyingqiu Liu, Bingbing Gao, Yanwei Miao, Xiang Dong

    Iron deposits in the red nucleus at long-term follow-up after hypertrophic olivary degeneration


  • Acceleration of Brain TOF-MRA with Compressed Sensitivity Encoding: A Multicenter Clinical Study

    by J. Ding, Y. Duan, Z. Zhuo, Y. Yuan, G. Zhang, Q. Song, B. Gao, B. Zhang, M. Wang, L. Yang, et al.

    BACKGROUND AND PURPOSE: The clinical practice of three-dimensional TOF-MRA, despite its capability in brain artery assessment, has been hampered by the relatively long scan time, while recent developments in fast imaging techniques with random undersampling has shed light on an improved balance between image quality and imaging speed. Our aim was to evaluate the effectiveness of TOF-MRA accelerated by compressed sensitivity encoding and to identify the optimal acceleration factors for routine clinical use. MATERIALS AND METHODS: One hundred subjects, enrolled at 5 centers, underwent 8 brain TOF-MRA sequences: 5 sequences using compressed sensitivity encoding with acceleration factors of 2, 4, 6, 8, and 10 (CS2, CS4, CS6, CS8, and CS10), 2 using sensitivity encoding with factors of 2 and 4 (SF2 and SF4), and 1 without acceleration as a reference sequence (RS). Five large arteries, 6 medium arteries, and 6 small arteries were evaluated quantitatively (reconstructed signal intensity, structural similarity, contrast ratio) and qualitatively (scores on arteries, artifacts, overall image quality, and diagnostic confidence for aneurysm and stenosis). Comparisons were performed among the 8 sequences. RESULTS: The quantitative measurements showed that the reconstructed signal intensities of the assessed arteries and the structural similarity consistently decreased as the compressed sensitivity encoding acceleration factor increased, and no significant difference was found for the contrast ratios in pair-wise comparisons among SF2, CS2, and CS4. Qualitative evaluations showed no significant difference in pair-wise comparisons among RS, SF2, and CS2 (P > .05). The visualization of all the assessed arteries was acceptable for CS2 and CS4, while 2 small arteries in images of CS6 were not reliably displayed, and the visualization of large arteries was acceptable in images of CS8 and CS10. CONCLUSIONS: CS4 is recommended for routine brain TOF-MRA with balanced image quality and acquisition time; CS6, for examinations when small arteries are not evaluated; and CS10, for fast visualization of large arteries.