HLH. Liu

H. Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


H. Liu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Bing Zhang

    Department of Radiology, Nanjing Drum Tower Hospital Clinical College of Nanjing University of Chinese Medicine, Nanjing, China

    1 shared publication
  • Bingbing Gao

    From the Department of Radiology (B.G., M.Q., Y.J., W.l., M.W., C.Y., Y.M), The First Affiliated Hospital of Dalian Medical University, Dalian, China

    1 shared publication
  • F. Zheng

    From the Department of Radiology (J.D., Y.D., Z.Z., L.G., F.Z., R.C., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China

    1 shared publication
  • G. Zhang

    Department of Radiology (Y.Y., G.Z.), Beijing Royal Integrative Medicine Hospital, Beijing, China

    1 shared publication
  • Jiazheng Wang

    Clinical & Technical Support, Philips Healthcare, Beijing, China

    1 shared publication
  • Jinli Ding

    Department of Radiology, Beijing You'an Hospital Affiliated to Capital Medical University, No.8, Xi Tou Tiao, You An Men Wai, Feng Tai District, Beijing 100069, China

    1 shared publication

Latest Publications

  • Acceleration of Brain Susceptibility-Weighted Imaging with Compressed Sensitivity Encoding: A Prospective Multicenter Study

    by J. Ding, Y. Duan, M. Wang, Y. Yuan, Z. Zhuo, L. Gan, Q. Song, B. Gao, L. Yang, H. Liu, et al.

    BACKGROUND AND PURPOSE: While three-dimensional susceptibility-weighted imaging has been widely suggested for intracranial vessel imaging, hemorrhage detection, and other neuro-diseases, its relatively long scan time has necessitated the clinical verification of recent progresses of fast imaging techniques. Our aim was to evaluate the effectiveness of brain SWI accelerated by compressed sensitivity encoding to identify the optimal acceleration factors for clinical practice. MATERIALS AND METHODS: Ninety-nine subjects, prospectively enrolled from 5 centers, underwent 8 brain SWI sequences: 5 different folds of compressed sensitivity encoding acceleration (CS2, CS4, CS6, CS8, and CS10), 2 different folds of sensitivity encoding acceleration (SF2 and SF4), and 1 without acceleration. Images were assessed quantitatively on both the SNR of the red nucleus and its contrast ratio to the CSF and, subjectively, with scoring on overall image quality; visibility of the substantia nigra–red nucleus, basilar artery, and internal cerebral vein; and diagnostic confidence of the cerebral microbleeds and other intracranial diseases. RESULTS: Compressed sensitivity encoding showed a promising ability to reduce the acquisition time (from 202 to 41 seconds) of SWI while increasing the acceleration factor from 2 to 10, though at the cost of decreasing the SNR, contrast ratio, and the scores of visual assessments. The visibility of the substantia nigra–red nucleus and internal cerebral vein became unacceptable in CS6 to CS10. The basilar artery was well-distinguished, and diseases including cerebral microbleeds, cavernous angiomas, intracranial gliomas, venous malformations, and subacute hemorrhage were well-diagnosed in all compressed sensitivity encoding sequences. CONCLUSIONS: Compressed sensitivity encoding factor 4 is recommended in routine practice. Compressed sensitivity encoding factor 10 is potentially a fast surrogate for distinguishing the basilar artery and detecting susceptibility-related abnormalities (eg, cerebral microbleeds, cavernous angiomas, gliomas, and venous malformation) at the sacrifice of visualization of the substantia nigra–red nucleus and internal cerebral vein.