Influence of different lubricants on the retentive force of LOCATOR® attachments – an in vitro pilot study
- 9 September 2015
- journal article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 27 (7) , 771-775
Abstract
Objective: The aim of this in vitro pilot study was to evaluate the influence of an artificial saliva (AS) lubricant on the retentive force of a stud‐type attachment (LOCATOR®) for implant overdentures (IODs).Methods: Twenty custom‐made models simulating a two‐IOD with parallel implant situation were fabricated using LOCATOR® attachments. The in vitro testing was carried out with an Instron® universal testing machine for a total of 10,000 insertion–removal cycles, for each model, in two different aqueous test mediums (Group 1: 0.9% sodium chloride solution (NaCl), n = 10; Group 2: AS, n = 10). Changes in the mean retentive force (F) were plotted against the cycle numbers #10, #100, #1000, #5000, and #10,000. Mixed regression models were applied for statistical analyses.Results: A mixed regression (not considering interactions) predicted, compared to cycle #10, higher retentive forces at cycles #100 (P < 0.0001), #1000 (P = 0.017), similar forces at #5000 (P = 0.277), and lower forces at #10,000 (P = 0.012); there was no overall effect of the medium (P = 0.159). A second statistical model, employing the interaction term “cycle##medium”, confirmed similarly the effect. Although the interaction term was significant at cycle #100 (p = 0.045), there was no significant difference between the two groups (P = 0.140).Conclusion: In this in vitro pilot experiment, there was no difference in mean retentive forces of the LOCATOR® attachments when tested with either 0.9% NaCl or a Glandosane®‐like artificial saliva lubricant. A larger scale study may still confirm the superiority of either lubricant for quasiclinical bench experiments.Keywords
Funding Information
- Institut Straumann, AG, Basel, Switzerland
This publication has 17 references indexed in Scilit:
- The Effect of Denture Cleansing Solutions on the Retention of Pink Locator Attachments after Multiple Pulls: An In Vitro StudyJournal of Prosthodontics, 2011
- Attachment systems for implant overdenture: influence of implant inclination on retentive and lateral forcesClinical Oral Implants Research, 2011
- Effect of simulated masticatory loading on the retention of stud attachments for implant overdenturesJournal of Oral Rehabilitation, 2010
- A Comparison of Three Different Attachment Systems for Mandibular Two‐Implant Overdentures: One‐Year ReportClinical Implant Dentistry and Related Research, 2010
- Influence of the lubricant and the alloy on the wear behaviour of attachmentsGerodontology, 2010
- Statistical power analyses using G*Power 3.1: Tests for correlation and regression analysesBehavior Research Methods, 2009
- Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients - the York Consensus StatementBritish Dental Journal, 2009
- The Change in Retentive Values of Locator Attachments and Hader Clips over TimeJournal of Prosthodontics, 2009
- Retention force and fatigue strength of overdenture attachment systemsJournal of Oral Rehabilitation, 2004
- About a synthetic saliva for in vitro studiesTalanta, 2001