Comparison of devices used in carotid artery stenting: A vascular quality initiative analysis of commonly used carotid stents and embolic protection devices
- 18 July 2018
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (4) , 743-749
Abstract
Background: Data regarding efficacy of various stent and embolic protection device (EPD) combinations to prevent stroke during carotid artery stenting (CAS) is limited. We compared post‐procedure inpatient neurologic outcomes across various carotid stent‐EPD platforms recorded in the Vascular Quality Initiative (VQI) registry.Methods: We analyzed 13,786 consecutive CAS procedures in the VQI registry performed between January 1, 2005 and December 31, 2015. The most commonly used stent‐EPD combinations (n = 5407) were included in the analysis. Post‐procedure inpatient neurologic outcomes included (1) ipsilateral stroke/transient ischemic attack (TIA) and (2) any stroke/TIA. Multivariate generalized estimating equation regression analysis was performed, adjusting for age, sex, tobacco use, coronary artery disease, congestive heart failure, prior stroke/TIA, hypertension, history of carotid revascularization, and presence of a second ipsilateral stenosis >70%, to determine whether risk of outcomes differed according to device.Results: Of 13,786 CAS procedures, Xact‐Emboshield (n = 2,438, 17.6%), Precise‐Angioguard (n = 1,480, 10.7%), Acculink‐Accunet (n = 829, 6.01%), and Acculink‐Emboshield (n = 660, 4.8%) were the most commonly used combinations, accounting for a total of 5,407 procedures. Inpatient event rates for ipsilateral stroke/TIA and any stroke/TIA were 1.9 and 2.7% in the Accunet‐Acculink, 3.0 and 3.2% in Acculink‐Emboshield, 3.2 and 4.1% in Precise‐Angioguard and 2.2 and 3.0% in Xact‐Emboshield. There was no evidence of difference in risk of ipsilateral stroke/TIA or any stroke/TIA across device combinations (P = 0.15 and P = 0.16, respectively).Conclusion: CAS with current carotid stent‐EPD combinations is associated with low rates of inpatient stroke/TIA. There is no statistically significant difference in rates of inpatient stroke/TIA across device combinations.Keywords
This publication has 25 references indexed in Scilit:
- Comparison of carotid endarterectomy and stenting in real world practice using a regional quality improvement registryJournal of Vascular Surgery, 2012
- Stenting versus Endarterectomy for Treatment of Carotid-Artery StenosisNew England Journal of Medicine, 2010
- Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trialThe Lancet, 2010
- Thirty-Day Outcomes for Carotid Artery Stenting in 6320 Patients From 2 Prospective, Multicenter, High-Surgical-Risk RegistriesCirculation: Cardiovascular Interventions, 2009
- Comparison of Carotid Stents: An In-Vitro Experiment Focusing on Stent DesignJournal of Endovascular Therapy, 2009
- The type of embolic protection does not influence the outcome in carotid artery stentingJournal of Vascular Surgery, 2007
- Endarterectomy versus Stenting in Patients with Symptomatic Severe Carotid StenosisNew England Journal of Medicine, 2006
- Embolic protection devices for carotid artery stenting: better results than stenting without protection?European Heart Journal, 2004
- Carotid Revascularization for Prevention of Stroke: Carotid Endarterectomy and Carotid Artery StentingMayo Clinic Proceedings, 2004
- Updated review of the global carotid artery stent registryCatheterization and Cardiovascular Interventions, 2003