Ashwat Singh Dhillon
Ashwat Singh Dhillon has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Leonardo C. Clavijo
Division of Cardiovascular Medicine, University of Southern California, Los Angeles, CA, United States of America
5 shared publications - Noor Al-Asady
Division of Cardiovascular Medicine, Keck School of Medicine, University of Southern California, Los Angeles, CA, United States
4 shared publications - David M. Shavelle
Long Beach Medical Center, Long Beach, CA, USA
3 shared publications - Ray V. Matthews
Division of Cardiovascular Medicine, Keck School of Medicine, University of Southern California, Los Angeles, CA, United States of America
2 shared publications - Vincent Lopez Rowe
Keck School of Medicine
2 shared publications - Brandon M. Jones
Cleveland Clinic, Cleveland, OH, USA
1 shared publication
Latest Publications
- 25 March 2022
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 34 (5) , E369-E373
Transcatheter Aortic Valve Replacement for Severe Aortic Regurgitation in Patients With a Left Ventricular Assist Device
This is a retrospective chart review of 4 patients with LVAD who underwent TAVR for severe AR. All 4 patients underwent TAVR with a 34-mm self-expanding valve.
- 25 March 2022
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 34 (5) , E369-E373
Transcatheter Aortic Valve Replacement for Severe Aortic Regurgitation in Patients With a Left Ventricular Assist Device
This is a retrospective chart review of 4 patients with LVAD who underwent TAVR for severe AR. All 4 patients underwent TAVR with a 34-mm self-expanding valve.
- 24 September 2019
- Published by SAGE Publications in Journal of Cardiovascular Pharmacology and Therapeutics
- Vol. 25 (2) , 158-163
Therapeutic Window of Clopidogrel and Ticagrelor in Patients With Critical Limb-Threatening Ischemia
Critical limb-threatening ischemia (CLTI) is associated with an increased risk of major adverse limb events and mortality. High on-treatment platelet reactivity (HPR) is associated with an increased risk of ischemic events, while low on-treatment platelet reactivity (LPR) is associated with an increased risk of bleeding. This study investigates the frequency with which patients with CLTI on clopidogrel or ticagrelor achieve a “therapeutic window” (TW) of platelet inhibition. Data from the “Switch To Ticagrelor in Critical Limb Ischemia Anti-Platelet Study” were assessed retrospectively to determine the incidence of TW of on-treatment platelet reactivity in 50 consecutive patients with CLTI (mean age: 65.2 ± 10.5 years, 54% male). The data included 4 measurements of patients’ platelet reactivity using the VerifyNow P2Y12 Assay: baseline and steady state platelet reactivity on clopidogrel 75 mg daily and on ticagrelor 90 mg twice daily. At baseline, 46% of patients on clopidogrel were within TW of on-treatment platelet reactivity compared to 10% of patients on ticagrelor (P < .0001). At steady state, 42% of patients on clopidogrel were within the TW compared to 10% of patients on ticagrelor (P < .0001). Patients on ticagrelor exhibited higher rates of LPR compared to those on clopidogrel at baseline as well as at steady state (baseline 88% vs 18%, steady state 88% vs 28%; P < .0001). Although ticagrelor has been proposed as an alternative for patients with HPR on clopidogrel, the current study observes an excess of platelet inhibition with ticagrelor in most patients with CLTI at a dose of 90 mg twice daily.
- 24 September 2019
- Published by SAGE Publications in Journal of Cardiovascular Pharmacology and Therapeutics
- Vol. 25 (2) , 158-163
Therapeutic Window of Clopidogrel and Ticagrelor in Patients With Critical Limb-Threatening Ischemia
Critical limb-threatening ischemia (CLTI) is associated with an increased risk of major adverse limb events and mortality. High on-treatment platelet reactivity (HPR) is associated with an increased risk of ischemic events, while low on-treatment platelet reactivity (LPR) is associated with an increased risk of bleeding. This study investigates the frequency with which patients with CLTI on clopidogrel or ticagrelor achieve a “therapeutic window” (TW) of platelet inhibition. Data from the “Switch To Ticagrelor in Critical Limb Ischemia Anti-Platelet Study” were assessed retrospectively to determine the incidence of TW of on-treatment platelet reactivity in 50 consecutive patients with CLTI (mean age: 65.2 ± 10.5 years, 54% male). The data included 4 measurements of patients’ platelet reactivity using the VerifyNow P2Y12 Assay: baseline and steady state platelet reactivity on clopidogrel 75 mg daily and on ticagrelor 90 mg twice daily. At baseline, 46% of patients on clopidogrel were within TW of on-treatment platelet reactivity compared to 10% of patients on ticagrelor (P < .0001). At steady state, 42% of patients on clopidogrel were within the TW compared to 10% of patients on ticagrelor (P < .0001). Patients on ticagrelor exhibited higher rates of LPR compared to those on clopidogrel at baseline as well as at steady state (baseline 88% vs 18%, steady state 88% vs 28%; P < .0001). Although ticagrelor has been proposed as an alternative for patients with HPR on clopidogrel, the current study observes an excess of platelet inhibition with ticagrelor in most patients with CLTI at a dose of 90 mg twice daily.
- 18 July 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (4) , 743-749
Comparison of devices used in carotid artery stenting: A vascular quality initiative analysis of commonly used carotid stents and embolic protection devices
Background: Data regarding efficacy of various stent and embolic protection device (EPD) combinations to prevent stroke during carotid artery stenting (CAS) is limited. We compared post‐procedure inpatient neurologic outcomes across various carotid stent‐EPD platforms recorded in the Vascular Quality Initiative (VQI) registry.Methods: We analyzed 13,786 consecutive CAS procedures in the VQI registry performed between January 1, 2005 and December 31, 2015. The most commonly used stent‐EPD combinations (n = 5407) were included in the analysis. Post‐procedure inpatient neurologic outcomes included (1) ipsilateral stroke/transient ischemic attack (TIA) and (2) any stroke/TIA. Multivariate generalized estimating equation regression analysis was performed, adjusting for age, sex, tobacco use, coronary artery disease, congestive heart failure, prior stroke/TIA, hypertension, history of carotid revascularization, and presence of a second ipsilateral stenosis >70%, to determine whether risk of outcomes differed according to device.Results: Of 13,786 CAS procedures, Xact‐Emboshield (n = 2,438, 17.6%), Precise‐Angioguard (n = 1,480, 10.7%), Acculink‐Accunet (n = 829, 6.01%), and Acculink‐Emboshield (n = 660, 4.8%) were the most commonly used combinations, accounting for a total of 5,407 procedures. Inpatient event rates for ipsilateral stroke/TIA and any stroke/TIA were 1.9 and 2.7% in the Accunet‐Acculink, 3.0 and 3.2% in Acculink‐Emboshield, 3.2 and 4.1% in Precise‐Angioguard and 2.2 and 3.0% in Xact‐Emboshield. There was no evidence of difference in risk of ipsilateral stroke/TIA or any stroke/TIA across device combinations (P = 0.15 and P = 0.16, respectively).Conclusion: CAS with current carotid stent‐EPD combinations is associated with low rates of inpatient stroke/TIA. There is no statistically significant difference in rates of inpatient stroke/TIA across device combinations.
- 18 July 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (4) , 743-749
Comparison of devices used in carotid artery stenting: A vascular quality initiative analysis of commonly used carotid stents and embolic protection devices
Background: Data regarding efficacy of various stent and embolic protection device (EPD) combinations to prevent stroke during carotid artery stenting (CAS) is limited. We compared post‐procedure inpatient neurologic outcomes across various carotid stent‐EPD platforms recorded in the Vascular Quality Initiative (VQI) registry.Methods: We analyzed 13,786 consecutive CAS procedures in the VQI registry performed between January 1, 2005 and December 31, 2015. The most commonly used stent‐EPD combinations (n = 5407) were included in the analysis. Post‐procedure inpatient neurologic outcomes included (1) ipsilateral stroke/transient ischemic attack (TIA) and (2) any stroke/TIA. Multivariate generalized estimating equation regression analysis was performed, adjusting for age, sex, tobacco use, coronary artery disease, congestive heart failure, prior stroke/TIA, hypertension, history of carotid revascularization, and presence of a second ipsilateral stenosis >70%, to determine whether risk of outcomes differed according to device.Results: Of 13,786 CAS procedures, Xact‐Emboshield (n = 2,438, 17.6%), Precise‐Angioguard (n = 1,480, 10.7%), Acculink‐Accunet (n = 829, 6.01%), and Acculink‐Emboshield (n = 660, 4.8%) were the most commonly used combinations, accounting for a total of 5,407 procedures. Inpatient event rates for ipsilateral stroke/TIA and any stroke/TIA were 1.9 and 2.7% in the Accunet‐Acculink, 3.0 and 3.2% in Acculink‐Emboshield, 3.2 and 4.1% in Precise‐Angioguard and 2.2 and 3.0% in Xact‐Emboshield. There was no evidence of difference in risk of ipsilateral stroke/TIA or any stroke/TIA across device combinations (P = 0.15 and P = 0.16, respectively).Conclusion: CAS with current carotid stent‐EPD combinations is associated with low rates of inpatient stroke/TIA. There is no statistically significant difference in rates of inpatient stroke/TIA across device combinations.
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S75
CRT-800.43 Left Atrial Appendage Occlusion for Atrial Fibrillation: Eligibility in a Typical Oral Anticoagulation Clinic
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S75
CRT-800.43 Left Atrial Appendage Occlusion for Atrial Fibrillation: Eligibility in a Typical Oral Anticoagulation Clinic
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S41
CRT-300.03 Role of Transthoracic Echocardiography in the Preoperative Evaluation of Patients with Critical Limb Ischemia Undergoing Surgical Bypass
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S41
CRT-300.03 Role of Transthoracic Echocardiography in the Preoperative Evaluation of Patients with Critical Limb Ischemia Undergoing Surgical Bypass
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S66-S67
CRT-800.14 Percutaneous Coronary Intervention Prior to Transcatheter Aortic Valve Replacement: A Matched Cohort Analysis
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S66-S67
CRT-800.14 Percutaneous Coronary Intervention Prior to Transcatheter Aortic Valve Replacement: A Matched Cohort Analysis
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S40
CRT-300.00 Infra-Popliteal Drug-Eluting Stenting In Patients With Rutherford Class VI Critical Limb Ischemia
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S40
CRT-300.00 Infra-Popliteal Drug-Eluting Stenting In Patients With Rutherford Class VI Critical Limb Ischemia
- 25 November 2014
- Published by Wolters Kluwer Health in Circulation
- Vol. 130 (suppl_2)
Abstract 19134: Elevated Troponin T is Associated with Adverse Outcomes After Aortic Valve Replacement
Background: Data regarding association of elevated cardiac enzymes and adverse outcomes in patients who undergo aortic valve replacement (AVR) has been inconclusive. Role of coronary revascularization prior to AVR remains uncertain. We sought to understand prognostic implication of post procedure troponin T (TnT) elevation in patients undergoing AVR. Hypothesis: We hypothesized that patients with significantly elevated TnT after AVR will have worse outcomes representing important coronary circulation which is not revascularized. Methods: We retrospectively studied 4648 consecutive patients who underwent AVR at a single tertiary care center between January 2007 and December 2013. These were divided into surgical AVR (SAVR) and transcatheter AVR (TAVR). Median post procedure peak TnT was identified in the SAVR and TAVR groups. Patients were divided into quartiles based on median TnT level. Results: Of 4648 patients who underwent AVR, 4200 (66% male) were SAVR and 448 (59% male) were TAVR. Median post procedure peak TnT values in the TAVR and SAVR group were 0.19 [0.08-0.39] & 0.36 [0.22-0.64] respectively (pth percentile, 6 month mortality was 0.7% & 1.8% after SAVR & TAVR respectively (p=0.1). In patients with TnT higher than 50th percentile, 6 month mortality was 2.4% & 3.6% after SAVR & TAVR respectively (p=0.26). In the SAVR group, mortality was 0.7% in patients with TnT levels less than 50th percentile & 2.4% in patients with TnT higher than 50th percentile (pConclusion: Peak troponin T was significantly higher after SAVR as compared to TAVR. Higher post procedure peak TnT is associated with increased 6 month mortality. These results are highly significant in the SAVR group. The mechanism and significance of these findings requires further studies. Download figure
- 25 November 2014
- Published by Wolters Kluwer Health in Circulation
- Vol. 130 (suppl_2)
Abstract 19134: Elevated Troponin T is Associated with Adverse Outcomes After Aortic Valve Replacement
Background: Data regarding association of elevated cardiac enzymes and adverse outcomes in patients who undergo aortic valve replacement (AVR) has been inconclusive. Role of coronary revascularization prior to AVR remains uncertain. We sought to understand prognostic implication of post procedure troponin T (TnT) elevation in patients undergoing AVR. Hypothesis: We hypothesized that patients with significantly elevated TnT after AVR will have worse outcomes representing important coronary circulation which is not revascularized. Methods: We retrospectively studied 4648 consecutive patients who underwent AVR at a single tertiary care center between January 2007 and December 2013. These were divided into surgical AVR (SAVR) and transcatheter AVR (TAVR). Median post procedure peak TnT was identified in the SAVR and TAVR groups. Patients were divided into quartiles based on median TnT level. Results: Of 4648 patients who underwent AVR, 4200 (66% male) were SAVR and 448 (59% male) were TAVR. Median post procedure peak TnT values in the TAVR and SAVR group were 0.19 [0.08-0.39] & 0.36 [0.22-0.64] respectively (pth percentile, 6 month mortality was 0.7% & 1.8% after SAVR & TAVR respectively (p=0.1). In patients with TnT higher than 50th percentile, 6 month mortality was 2.4% & 3.6% after SAVR & TAVR respectively (p=0.26). In the SAVR group, mortality was 0.7% in patients with TnT levels less than 50th percentile & 2.4% in patients with TnT higher than 50th percentile (pConclusion: Peak troponin T was significantly higher after SAVR as compared to TAVR. Higher post procedure peak TnT is associated with increased 6 month mortality. These results are highly significant in the SAVR group. The mechanism and significance of these findings requires further studies. Download figure
- 1 April 2014
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 20 (4) , 292-293
Incremental Use of Biomarkers and Electrocardiogram in Differentiating Takotsubo Cardiomyopathy From Acute Myocardial Infarction: A Potential Way to Go
- 1 April 2014
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 20 (4) , 292-293
Incremental Use of Biomarkers and Electrocardiogram in Differentiating Takotsubo Cardiomyopathy From Acute Myocardial Infarction: A Potential Way to Go