Leonardo C. Clavijo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Leonardo C. Clavijo has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Ashwat Singh Dhillon
Providence Valve Center, 9427 SW Barnes Road, West Pavilion, 5th Floor, Suite 593, Portland, OR 97225 USA.
5 shared publications - David M. Shavelle
Long Beach Medical Center, Long Beach, CA, USA
4 shared publications - Noor Al-Asady
Division of Cardiovascular Medicine, Keck School of Medicine, University of Southern California, Los Angeles, CA, United States
4 shared publications Augusto D. Pichard
Division of Cardiology Washington Hospital Center Washington, DC
3 shared publicationsKenneth M. Kent
Division of Cardiology Washington Hospital Center Washington, DC
3 shared publications- Lowell F. Satler
Section of Interventional Cardiology MedStar Washington Hospital Center Washington District of Columbia USA
3 shared publications
Latest Publications
- 1 January 2020
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 21 (1) , 118-121
“The Renal Foot” - Angiographic Pattern of Patients with Chronic Limb Threatening Ischemia and End-Stage Renal Disease
- 1 January 2020
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 21 (1) , 118-121
“The Renal Foot” - Angiographic Pattern of Patients with Chronic Limb Threatening Ischemia and End-Stage Renal Disease
- 18 July 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (4) , 743-749
Comparison of devices used in carotid artery stenting: A vascular quality initiative analysis of commonly used carotid stents and embolic protection devices
Background: Data regarding efficacy of various stent and embolic protection device (EPD) combinations to prevent stroke during carotid artery stenting (CAS) is limited. We compared post‐procedure inpatient neurologic outcomes across various carotid stent‐EPD platforms recorded in the Vascular Quality Initiative (VQI) registry.Methods: We analyzed 13,786 consecutive CAS procedures in the VQI registry performed between January 1, 2005 and December 31, 2015. The most commonly used stent‐EPD combinations (n = 5407) were included in the analysis. Post‐procedure inpatient neurologic outcomes included (1) ipsilateral stroke/transient ischemic attack (TIA) and (2) any stroke/TIA. Multivariate generalized estimating equation regression analysis was performed, adjusting for age, sex, tobacco use, coronary artery disease, congestive heart failure, prior stroke/TIA, hypertension, history of carotid revascularization, and presence of a second ipsilateral stenosis >70%, to determine whether risk of outcomes differed according to device.Results: Of 13,786 CAS procedures, Xact‐Emboshield (n = 2,438, 17.6%), Precise‐Angioguard (n = 1,480, 10.7%), Acculink‐Accunet (n = 829, 6.01%), and Acculink‐Emboshield (n = 660, 4.8%) were the most commonly used combinations, accounting for a total of 5,407 procedures. Inpatient event rates for ipsilateral stroke/TIA and any stroke/TIA were 1.9 and 2.7% in the Accunet‐Acculink, 3.0 and 3.2% in Acculink‐Emboshield, 3.2 and 4.1% in Precise‐Angioguard and 2.2 and 3.0% in Xact‐Emboshield. There was no evidence of difference in risk of ipsilateral stroke/TIA or any stroke/TIA across device combinations (P = 0.15 and P = 0.16, respectively).Conclusion: CAS with current carotid stent‐EPD combinations is associated with low rates of inpatient stroke/TIA. There is no statistically significant difference in rates of inpatient stroke/TIA across device combinations.
- 18 July 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (4) , 743-749
Comparison of devices used in carotid artery stenting: A vascular quality initiative analysis of commonly used carotid stents and embolic protection devices
Background: Data regarding efficacy of various stent and embolic protection device (EPD) combinations to prevent stroke during carotid artery stenting (CAS) is limited. We compared post‐procedure inpatient neurologic outcomes across various carotid stent‐EPD platforms recorded in the Vascular Quality Initiative (VQI) registry.Methods: We analyzed 13,786 consecutive CAS procedures in the VQI registry performed between January 1, 2005 and December 31, 2015. The most commonly used stent‐EPD combinations (n = 5407) were included in the analysis. Post‐procedure inpatient neurologic outcomes included (1) ipsilateral stroke/transient ischemic attack (TIA) and (2) any stroke/TIA. Multivariate generalized estimating equation regression analysis was performed, adjusting for age, sex, tobacco use, coronary artery disease, congestive heart failure, prior stroke/TIA, hypertension, history of carotid revascularization, and presence of a second ipsilateral stenosis >70%, to determine whether risk of outcomes differed according to device.Results: Of 13,786 CAS procedures, Xact‐Emboshield (n = 2,438, 17.6%), Precise‐Angioguard (n = 1,480, 10.7%), Acculink‐Accunet (n = 829, 6.01%), and Acculink‐Emboshield (n = 660, 4.8%) were the most commonly used combinations, accounting for a total of 5,407 procedures. Inpatient event rates for ipsilateral stroke/TIA and any stroke/TIA were 1.9 and 2.7% in the Accunet‐Acculink, 3.0 and 3.2% in Acculink‐Emboshield, 3.2 and 4.1% in Precise‐Angioguard and 2.2 and 3.0% in Xact‐Emboshield. There was no evidence of difference in risk of ipsilateral stroke/TIA or any stroke/TIA across device combinations (P = 0.15 and P = 0.16, respectively).Conclusion: CAS with current carotid stent‐EPD combinations is associated with low rates of inpatient stroke/TIA. There is no statistically significant difference in rates of inpatient stroke/TIA across device combinations.
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S75
CRT-800.43 Left Atrial Appendage Occlusion for Atrial Fibrillation: Eligibility in a Typical Oral Anticoagulation Clinic
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S75
CRT-800.43 Left Atrial Appendage Occlusion for Atrial Fibrillation: Eligibility in a Typical Oral Anticoagulation Clinic
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S41
CRT-300.03 Role of Transthoracic Echocardiography in the Preoperative Evaluation of Patients with Critical Limb Ischemia Undergoing Surgical Bypass
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S41
CRT-300.03 Role of Transthoracic Echocardiography in the Preoperative Evaluation of Patients with Critical Limb Ischemia Undergoing Surgical Bypass
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S66-S67
CRT-800.14 Percutaneous Coronary Intervention Prior to Transcatheter Aortic Valve Replacement: A Matched Cohort Analysis
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S66-S67
CRT-800.14 Percutaneous Coronary Intervention Prior to Transcatheter Aortic Valve Replacement: A Matched Cohort Analysis
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S40
CRT-300.00 Infra-Popliteal Drug-Eluting Stenting In Patients With Rutherford Class VI Critical Limb Ischemia
- 1 February 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (3) , S40
CRT-300.00 Infra-Popliteal Drug-Eluting Stenting In Patients With Rutherford Class VI Critical Limb Ischemia
- 27 October 2016
- Published by Springer Nature
- p. 441-449
Endovascular and Thrombolytic Therapy for Upper and Lower Extremity Acute Limb Ischemia
- 27 October 2016
- Published by Springer Nature
- p. 441-449
Endovascular and Thrombolytic Therapy for Upper and Lower Extremity Acute Limb Ischemia
- 1 April 2016
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 17 (3) , 155-161
Same-day discharge after coronary stenting and femoral artery device closure: A randomized study in stable and low-risk acute coronary syndrome patients
- 1 April 2016
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 17 (3) , 155-161
Same-day discharge after coronary stenting and femoral artery device closure: A randomized study in stable and low-risk acute coronary syndrome patients
- 1 February 2016
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 9 (4) , S39
CRT-300.20 Predictors of Endovascular Revascularization for Critical Limb Ischemia
- 1 February 2016
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 9 (4) , S39
CRT-300.20 Predictors of Endovascular Revascularization for Critical Limb Ischemia
- 1 February 2015
- Published by Elsevier in Cardiology Clinics
- Vol. 33 (1)
Vascular Disease