Evaluation of applying space-variant resolution modeling to attenuation correction in PET
- 7 June 2022
- journal article
- research article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (4) , 045009
Abstract
Attenuation correction aims to recover the underestimated tracer uptake and improve the image contrast recovery in positron emission tomography (PET). However, traditional ray-tracing-based projection of attenuation maps is inaccurate as some physical effects are not considered, such as finite crystal size, inter-crystal penetration and inter-crystal scatter. In this study, we evaluated the effects of applying resolution modeling (RM) to attenuation correction by implementing space-variant RM to complement physical effects which are usually omitted in the traditional projection model. We verified this method on a brain PET scanner developed by our group, in both Monte Carlo simulation and real-world data, in comparison with space-invariant Gaussian RM, average-depth-of-interaction, and multi-ray tracing methods. The results indicate that the space-variant RM is superior in terms of artifacts reduction and contrast recovery.Keywords
Funding Information
- National Research and Development Program for Major Research Instruments of Natural Science Foundation of China (62027808)
- National Key Research and Development Program of China (2018YFE0118900)
- Sino-German Mobility Programme (M-0387)
This publication has 36 references indexed in Scilit:
- Resolution modeling in PET imaging: Theory, practice, benefits, and pitfallsMedical Physics, 2013
- MRI for attenuation correction in PET: methods and challengesMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Non-Gaussian space-variant resolution modelling for list-mode reconstructionPhysics in Medicine & Biology, 2010
- Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PETPhysics in Medicine & Biology, 2010
- Iterative image reconstruction for positron emission tomography based on a detector response function estimated from point source measurementsPhysics in Medicine & Biology, 2009
- Impact of Image-Space Resolution Modeling for Studies with the High-Resolution Research TomographJournal of Nuclear Medicine, 2008
- A generalized model for the conversion from CT numbers to linear attenuation coefficientsIEEE Transactions on Nuclear Science, 2003
- EM algorithm system modeling by image-space techniques for PET reconstructionIEEE Transactions on Nuclear Science, 2003
- New, faster, image-based scatter correction for 3D PETIEEE Transactions on Nuclear Science, 2000
- Maximum-likelihood reconstruction of transmission images in emission computed tomography via the EM algorithmIEEE Transactions on Medical Imaging, 1994