Abstract
The Zeeman shift plays an important role in the evaluation of optical lattice clocks since a strong bias magnetic field is applied for departing Zeeman sublevels and defining a quantization axis. We demonstrated the frequency correction and uncertainty evaluation due to Zeeman shift in the 87Sr optical lattice clock at the National Time Service Center. The first-order Zeeman shift was almost completely removed by stabilizing the clock laser to the average frequency of the two Zeeman components of mF = ±9/2. The residual first-order Zeeman shift arose from the magnetic field drift between measurements of the two stretched-state center frequencies; the upper bound was inferred as 4(5) × 10−18. The quadratic Zeeman shift coefficient was experimentally determined as –23.0(4) MHz/T2 and the final Zeeman shift was evaluated as 9.20(7) × 10−17. The evaluation of the Zeeman shift is a foundation for overall evaluation of the uncertainty of an optical lattice clock. This measurement can provide more references for the determination of the quadratic coefficient of 87Sr.
Funding Information
  • National Natural Science Foundation of China (11803042 and 61775220)
  • the National Key R&D Program of China (2016YFF0200201)
  • the Key Research Project of Frontier Science of the Chinese Academy of Sciences (QYZDB-SSW-JSC004)
  • the Strategic Priority Research Program of the Chinese Academy of Sciences (XDB21030100)
  • Youth innovation promotion Association the Chinese Academy of Sciences (2019400)

This publication has 31 references indexed in Scilit: