XLXiaotong Lu

Xiaotong Lu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaotong Lu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Demonstration of the Systematic Evaluation of an Optical Lattice Clock Using the Drift-Insensitive Self-Comparison Method

    by Chihua Zhou, Xiaotong Lu, Benquan Lu, Yebing Wang, Hong Chang

    The self-comparison method is a powerful tool in the uncertainty evaluation of optical lattice clocks, but any drifts will cause a frequency offset between the two compared clock loops and thus lead to incorrect measurement result. We propose a drift-insensitive self-comparison method to remove this frequency offset by adjusting the clock detection sequence. We also experimentally demonstrate the validity of this method in a one-dimensional 87Sr optical lattice clock. As the clock laser frequency drift exists, the measured frequency difference between two identical clock loops is (240 ± 34) mHz using the traditional self-comparison method, while it is (−15 ± 16) mHz using the drift-insensitive self-comparison method, indicating that this frequency offset is cancelled within current measurement precision. We further use the drift-insensitive self-comparison technique to measure the collisional shift and the second-order Zeeman shift of our clock and the results show that the fractional collisional shift and the second-order Zeeman shift are 4.54(28) × 10−16 and 5.06(3) × 10−17, respectively.


  • Open Access

    An Evaluation of the Zeeman Shift of the 87Sr Optical Lattice Clock at the National Time Service Center

    by Xiaotong Lu, Mojuan Yin, Ting Li, Yebing Wang, Hong Chang

    The Zeeman shift plays an important role in the evaluation of optical lattice clocks since a strong bias magnetic field is applied for departing Zeeman sublevels and defining a quantization axis. We demonstrated the frequency correction and uncertainty evaluation due to Zeeman shift in the 87Sr optical lattice clock at the National Time Service Center. The first-order Zeeman shift was almost completely removed by stabilizing the clock laser to the average frequency of the two Zeeman components of mF = ±9/2. The residual first-order Zeeman shift arose from the magnetic field drift between measurements of the two stretched-state center frequencies; the upper bound was inferred as 4(5) × 10−18. The quadratic Zeeman shift coefficient was experimentally determined as –23.0(4) MHz/T2 and the final Zeeman shift was evaluated as 9.20(7) × 10−17. The evaluation of the Zeeman shift is a foundation for overall evaluation of the uncertainty of an optical lattice clock. This measurement can provide more references for the determination of the quadratic coefficient of 87Sr.


  • Open Access

    Recent Advances Concerning the 87Sr Optical Lattice Clock at the National Time Service Center

    by Yebing Wang, Xiaotong Lu, Benquan Lu, Dehuan Kong, Hong Chang

    We review recent experimental progress concerning the 87Sr optical lattice clock at the National Time Service Center in China. Hertz-level spectroscopy of the 87Sr clock transition for the optical lattice clock was performed, and closed-loop operation of the optical lattice clock was realized. A fractional frequency instability of 2.8 × 10−17 was attained for an averaging time of 2000 s. The Allan deviation is found to be 1.6 × 10−15/τ1/2 and is limited mainly by white-frequency-noise. The Landé g-factors of the (5s2)1S0 and (5s5p)3P0 states in 87Sr were measured experimentally; they are important for evaluating the clock’s Zeeman shifts. We also present recent work on the miniaturization of the strontium optical lattice clock for space applications.