Contribution of leakage flux to the total losses in transformers with magnetic shunt
Open Access
- 28 July 2020
- journal article
- research article
- Published by Taylor & Francis in International Journal of Electronics
- Vol. 108 (4) , 558-573
Abstract
To execute soft switching methods in resonant power converters, transformers with larger leakage inductance are getting more attention. Many papers have constructed various concepts in this regard. However, a discussion about, how the transformer efficiency is affected is lacking in the literature. This paper analyses the effects of the increased leakage inductance on the performance of the transformer. A transformer for increased leakage inductance is modelled and constructed to investigate the losses. The model discusses the effects of increased leakage inductance either by increasing the inter-winding spacing or by integrating the magnetic shunt within the transformer. The investigations show that increasing the leakage inductance by inserting a magnetic shunt can have severe degrading effects on the performance of the transformer, if not designed adequately. Additional losses are also calculated and the effects are verified by the experiments.Keywords
This publication has 27 references indexed in Scilit:
- A phase shifted full bridge converter with novel control over the leakage inductance2016
- An improved modelling and construction of power transformer for controlled leakage inductance2016
- Accurate Evaluation of Leakage Inductance in High-Frequency Transformers Using an Improved Frequency-Dependent ExpressionIEEE Transactions on Power Electronics, 2014
- A Very Low-Profile Dual Output LLC Resonant Converter for LCD/LED TV ApplicationsIEEE Transactions on Power Electronics, 2014
- High-Frequency High Power Density 3-D Integrated Gallium-Nitride-Based Point of Load Module DesignIEEE Transactions on Power Electronics, 2013
- Design of Leakage Inductance in Resonant DC-DC Converter for Electric Vehicle ChargerIEEE Transactions on Magnetics, 2012
- Optimization of the winding arrangement to increase the leakage inductance of a synchronous machine with multi-functional converter drive2011
- The role of parasitic inductance in high-power planar transformer design and converter integration2004
- Novel soft-switching DC-DC converter with full ZVS-range and reduced filter requirement. II. Constant-input, variable-output applicationsIEEE Transactions on Power Electronics, 2001