PARTITION EFFICIENCY OF HIGH-PITCH LOCULAR MULTILAYER COIL FOR COUNTERCURRENT CHROMATOGRAPHIC SEPARATION OF PROTEINS USING SMALL-SCALE CROSS-AXIS COIL PLANET CENTRIFUGE AND APPLICATION TO PURIFICATION OF VARIOUS COLLAGENASES WITH AQUEOUS-AQUEOUS POLYMER PHASE SYSTEMS
- 31 January 2011
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 34 (3) , 182-194
Abstract
Partition efficiency of the high-pitch locular multilayer coil was evaluated in countercurrent chromatographic (CCC) separation of proteins with an aqueous-aqueous polymer phase system using the small-scale cross-axis coil planet centrifuge (X-axis CPC) fabricated in our laboratory. The separation column was specially made by high-pitch (ca 5 cm) winding of 1.0 mm I.D., 2.0 mm O.D. locular tubing compressed at 2 cm intervals with a total capacity of 29.5 mL. The protein separation was performed using a set of stable proteins including cytochrome C, myoglobin, and lysozyme with the 12.5% (w/w) polyethylene glycol (PEG) 1000 and 12.5% (w/w) dibasic potassium phosphate system (pH 9.2) under 1000 rpm of column revolution. This high-pitch locular tubing yielded substantially higher stationary phase retention than the normal locular tubing for both lower and upper mobile phases. In order to demonstrate the capability of the high-pitch locular tubing, the purification of collagenase from the crude commercial sample was carried out using an aqueous-aqueous polymer phase system. Using the 16.0% (w/w) PEG 1000–6.3% (w/w) dibasic potassium phosphate–6.3% (w/w) monobasic potassium phosphate system (pH 6.6), collagenase I, II, IV, V, and X derived from Clostridium histolyticum were separated from other proteins and colored small molecular weight compounds present in the crude commercial sample. Collagenase from C. histolyticum well retained its enzymatic activity in the purified fractions. The overall results demonstrated that the high-pitch locular multilayer coil is effectively used for the CCC purification of bioactive compounds without loss of their enzymatic activities.Keywords
This publication has 16 references indexed in Scilit:
- Countercurrent chromatographic separation and purification of various ribonucleases using a small-scale cross-axis coil planet centrifuge with aqueous–aqueous polymer phase systemsJournal of Chromatography B, 2009
- Partition Efficiency of Newly Designed Locular Multilayer Coil for Countercurrent Chromatographic Separation of Proteins Using Small-Scale Cross-Axis Coil Planet Centrifuge with Aqueous-Aqueous Polymer Phase SystemsJournal of Liquid Chromatography & Related Technologies, 2009
- Purification and Characterization of a Major Collagenase fromStreptomyces parvulusBioscience, Biotechnology, and Biochemistry, 2009
- PROTEIN SEPARATION BY CROSS-AXIS COIL PLANET CENTRIFUGE WITH SPIRAL COLUMN ASSEMBLIESJournal of Liquid Chromatography & Related Technologies, 2002
- Effect of Elution Modes on Protein Separation by Cross-Axis Coil Planet Centrifuge with Two Different Types of Coiled ColumnsPreparative Biochemistry & Biotechnology, 1999
- Protein Separation by Cross-Axis Coil Planet Centrifuge with Two Different Types of Coiled ColumnsJournal of Liquid Chromatography & Related Technologies, 1998
- Protein Separation by Improved Cross-Axis Coil Planet Centrifuge with Eccentric Coil AssembliesJournal of Liquid Chromatography & Related Technologies, 1996
- Cross-Axis Synchronous Flow-Through Coil Planet Centrifuge Free of Rotary Seals for Preparative Countercurrent Chromatography. Part II. Studies on Phase Distribution and Partition Efficiency in Coaxial CoilsSeparation Science and Technology, 1987
- Cross-Axis Synchronous Flow-Through Coil Planet Centrifuge Free of Rotary Seals for Preparative Countercurrent Chromatography. Part I. Apparatus and Analysis of AccelerationSeparation Science and Technology, 1987
- Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4Nature, 1970