Impact of fenestrations and surface profiling on the holding of tissue by parallel occlusion laparoscopic graspers
- 24 December 2013
- journal article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 28 (4) , 1277-1283
Abstract
Despite the importance of efficient grasping during laparoscopic surgery, the published literature on jaw features, e.g., fenestrations and surface profiling on grasping efficiency defined as resistance to slip without inflicting trauma, is limited. Various surface geometries of the jaws were tested with respect to (i) inclusion of fenestrations; (ii) surface contact to fenestration area ratio, and (iii) surface profiling of the jaws. Various loads were applied to the tissue which was subsequently pulled at a constant rate until free from the jaws. The maximal force necessary to pull the tissue free was recorded. The jaws were designed for use in parallel-occlusion graspers to avoid the well documented high pinch forces encountered with pivoted occlusion. At all applied forces the force needed to pull tissue from any fenestration design was significantly higher than the force necessary to pull tissue from non-fenestrated jaws (p < 0.05) with no significant differences between the three fenestration designs. The ratio of surface contact to fenestration area must exceed 1:0.4 to achieve a significant increase in the tissue retention. All the profiles studied were made using a single fenestration and with a surface contact to fenestration area ratio of 1:0.8. All such profile designs studied performed significantly better than the control (p < 0.005). The ratio of the mean retraction to applied force across all load conditions tested were 1.23:1.0 and 1.7:1.0 for the waved and toothed profile respectively, with standard deviations for the corresponding retraction force of ±0.45 and ±0.38 respectively. The retention efficiency of laparoscopic graspers is improved by fenestration which must, however, exceed a certain ratio (>1.0:0.4). Likewise surface profiling of the jaws enhances retention efficiency and its design (tooth, waved, mixed) directly influences the amount of pressure needed to retain tissue.Keywords
This publication has 10 references indexed in Scilit:
- Fenestrations in the jaws of laparoscopic graspersMinimally Invasive Therapy & Allied Technologies, 2005
- Bowel injury as a complication of laparoscopyBritish Journal of Surgery, 2004
- Slip and damage properties of jaws of laparoscopic graspersSurgical Endoscopy, 2004
- Inter- and intraindividual variabilities of perforation forces of human and pig bowel tissueSurgical Endoscopy, 2003
- Forces and displacements in colon surgerySurgical Endoscopy, 2002
- Effectiveness of grasping and duration of clamping using laparoscopic graspersSurgical Endoscopy, 2002
- A curved edge moderates high pressure generated by a laparoscopic grasperSurgical Endoscopy, 2001
- Patterns of Failure at the Instrument–Tissue InterfaceJournal of Surgical Research, 2000
- HIGH PRESSURES ARE GENERATED AT THE TIP OF LAPAROSCOPIC GRASPERSAnz Journal of Surgery, 1999