  • Intraluminal magnetisation of bowel by ferromagnetic particles for retraction and manipulation by magnetic probes

    by Z. Wang, P. André, D. McLean, S.I. Brown, G.J. Florence, A. Cuschieri

    Feasibility studies are needed to demonstrate that safe and effective manipulation of bowel during Minimal Access Surgery (MAS) can be obtained by use of magnetic force. This paper characterises two classes of magnetic particles: stainless steel microparticles (SS-μPs) and iron oxide nanoparticles (IO-nPs) in terms of their magnetisation, chemical composition, crystallinity, morphology and size distribution. Both magnetic particles were dispersed in a high viscosity biological liquid for intraluminal injection of bowel. Ex vivo porcine bowel segments were then retracted by permanent magnetic probes of 5.0 and 10mm diameter. Strong retraction forces reaching 6N maximum were obtained by magnetic fluid based on dispersion of SS-μPs. In contrast, the IO-nP-based magnetic liquid generated less attraction force, due to both lower magnetic and solution properties of the IO-nPs. The comparison of the two particles allowed the identification of the rules to engineer the next generation of particles. The results with SS-μPs provide proof on concept that intraluminal injection of magnetic fluid can generate sufficient force for efficient bowel retraction. Thereafter we shall carry out in vivo animal studies for efficacy and safety of both types of ferrofluids.


  • Impact of fenestrations and surface profiling on the holding of tissue by parallel occlusion laparoscopic graspers

    by Andrew W. Brown, Stuart I. Brown, Donald Mclean, Zhigang Wang, Alfred Cuschieri

    Despite the importance of efficient grasping during laparoscopic surgery, the published literature on jaw features, e.g., fenestrations and surface profiling on grasping efficiency defined as resistance to slip without inflicting trauma, is limited. Various surface geometries of the jaws were tested with respect to (i) inclusion of fenestrations; (ii) surface contact to fenestration area ratio, and (iii) surface profiling of the jaws. Various loads were applied to the tissue which was subsequently pulled at a constant rate until free from the jaws. The maximal force necessary to pull the tissue free was recorded. The jaws were designed for use in parallel-occlusion graspers to avoid the well documented high pinch forces encountered with pivoted occlusion. At all applied forces the force needed to pull tissue from any fenestration design was significantly higher than the force necessary to pull tissue from non-fenestrated jaws (p < 0.05) with no significant differences between the three fenestration designs. The ratio of surface contact to fenestration area must exceed 1:0.4 to achieve a significant increase in the tissue retention. All the profiles studied were made using a single fenestration and with a surface contact to fenestration area ratio of 1:0.8. All such profile designs studied performed significantly better than the control (p < 0.005). The ratio of the mean retraction to applied force across all load conditions tested were 1.23:1.0 and 1.7:1.0 for the waved and toothed profile respectively, with standard deviations for the corresponding retraction force of ±0.45 and ±0.38 respectively. The retention efficiency of laparoscopic graspers is improved by fenestration which must, however, exceed a certain ratio (>1.0:0.4). Likewise surface profiling of the jaws enhances retention efficiency and its design (tooth, waved, mixed) directly influences the amount of pressure needed to retain tissue.


  • Rapid and Efficient Cell Labeling with A MRI Contrast Agent by Electroporation in The Presence of Protamine Sulfate

    by Lijun Wang, Zhigang Wang, Tim G Frank, Stuart I Brown, Sandy A Chudek, Alfred Cuschieri

    To investigate various protocols for magnetic labeling of human cancer cells with ferumoxides with a view to developing an effective and fast technique for potential clinical use in MRI. Transfection methods utilizing poly-L-lysine and protamine sulfate (PS), electroporation, and combination of PS with electroporation were evaluated in this in vitro study. Although transfection was more effective in terms of uptake rates (95-100%) and intracellular iron concentrations (4.01-7.34 pg/cell), all transfection agents required prolonged incubation. By contrast, electroporation yielded fast labeling but with a lower efficacy (68-75%, 1.63-2.59 pg/cell). The addition of PS to electroporation increased the labeling efficacy (80-91%, 2.84-4.16 pg/cell) and protected cell viability. This combined method also resulted in the best T(2)*-shortening effect in the in vitro cellular MRI. The combined PS-electroporation method provides a fast and efficient protocol for ferumoxide-based cellular imaging and therapeutic procedure.


  • Comparison of conventional and gaze-down imaging in laparoscopic task performance

    by S.I. Brown, T.G. Frank, G. Shallaly, A. Cuschieri

    Background: In video-assisted laparoscopy, the image is usually displayed on a monitor placed at approximately eye level. Video projection systems project the image onto a screen placed close to the hands. This is said to be ergonomically superior. To evaluate this approach, a proprietary projection system (PS) was compared to a monitor display (MD). Method: The resolution, ghosting, flickering, glare, contrast, color smear, and color matching of the two modalities were compared. A bowel-suturing task was employed to evaluate performance differences. Results: The image displayed by the first-generation PS is inferior to that of the MD in contrast and resolution measures, but it is comparable in the other image qualities. No significant differences in task performance were identified. Conclusions: The first-generation PS does not confer performance or comfort advantages over an MD. The theoretical advantages of the gaze-down stance are likely to be realized only if a high-quality projector is used.