Abstract
The existing low voltage (LV) earth fault detection techniques using residual current measurements cannot be effectively applied to the multi-earthed TN-C system. When an earth fault occurs on the multi-earthed TN-C system, the fault current passes through the combined protective and neutral (PEN) conductor back to the source, resulting in a low residual current. However, unbalanced load switching also generates residual current through the same path back to the source, thus making fault discrimination very difficult. To address this problem, the four-wire multi-earthed TN-C system was analyzed by decoupling the mode 0 and the mode N of the equivalent circuit so that the current characteristics can be clearly studied. A new earth fault detection method is developed which compares the residual current deviation with the PEN conductor current deviation. The scheme uses amplitude ratio and phase angle difference between these two measurements to discriminate between earth faults and unbalanced load switching. The feasibility of the proposed method was verified by digital simulation and by physical tests in an actual LV distribution network. Compared to approaches based only on residual current, the proposed method demonstrates better sensitivity and reliability.Keywords
Funding Information
- National Natural Science Foundation of China (52077221)
This publication has 26 references indexed in Scilit:
- A leakage protection method for low-voltage power supply systems based on flexible regulation of the neutral point voltageInternational Journal of Electrical Power & Energy Systems, 2023
- TN-C-S leakage protection method using residual and unbalanced currentIET Conference Proceedings, 2022
- Research on Key Technologies and Precise Protection of Leakage Accidents in Modern Distribution Network2022
- Study on the Detection Method of Leakage in TN-C Area of Low-voltage Distribution Network2021
- Application of WE-AE-BP Method to Electric Shock Faults Identification in the Low-voltage Distribution Network2020
- A generalizable and sensor-independent deep learning method for fault detection and location in low-voltage distribution gridsApplied Energy, 2020
- Novel protection scheme for residual current device‐based electric fault time detection and touch current identificationIET Generation, Transmission & Distribution, 2017
- Nuisance tripping of residual current circuit breakers in circuits supplying electronic loadsElectric Power Systems Research, 2016
- Of Electrical Distribution Systems With Multiple Grounded NeutralsIEEE Transactions on Industry Applications, 2010
- Of International Terminology and Wiring Methods Used in the Matter of Bonding and Earthing of Low-Voltage Power Systems2009