Zhongyu Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhongyu Sun has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Bingyin Xu
Shandong University of Technology
1 shared publication - Jian Li
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
1 shared publication - Meng Hou
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
1 shared publication - Mohan Jin
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
1 shared publication - Nan Peng
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
1 shared publication - Peng Zhang
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
1 shared publication
Latest Publications
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (2) , 1191-1202
Earth Fault Detection Method for TN-C Systems Based on Comparison of Current Deviations
The existing low voltage (LV) earth fault detection techniques using residual current measurements cannot be effectively applied to the multi-earthed TN-C system. When an earth fault occurs on the multi-earthed TN-C system, the fault current passes through the combined protective and neutral (PEN) conductor back to the source, resulting in a low residual current. However, unbalanced load switching also generates residual current through the same path back to the source, thus making fault discrimination very difficult. To address this problem, the four-wire multi-earthed TN-C system was analyzed by decoupling the mode 0 and the mode N of the equivalent circuit so that the current characteristics can be clearly studied. A new earth fault detection method is developed which compares the residual current deviation with the PEN conductor current deviation. The scheme uses amplitude ratio and phase angle difference between these two measurements to discriminate between earth faults and unbalanced load switching. The feasibility of the proposed method was verified by digital simulation and by physical tests in an actual LV distribution network. Compared to approaches based only on residual current, the proposed method demonstrates better sensitivity and reliability.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (2) , 1191-1202
Earth Fault Detection Method for TN-C Systems Based on Comparison of Current Deviations
The existing low voltage (LV) earth fault detection techniques using residual current measurements cannot be effectively applied to the multi-earthed TN-C system. When an earth fault occurs on the multi-earthed TN-C system, the fault current passes through the combined protective and neutral (PEN) conductor back to the source, resulting in a low residual current. However, unbalanced load switching also generates residual current through the same path back to the source, thus making fault discrimination very difficult. To address this problem, the four-wire multi-earthed TN-C system was analyzed by decoupling the mode 0 and the mode N of the equivalent circuit so that the current characteristics can be clearly studied. A new earth fault detection method is developed which compares the residual current deviation with the PEN conductor current deviation. The scheme uses amplitude ratio and phase angle difference between these two measurements to discriminate between earth faults and unbalanced load switching. The feasibility of the proposed method was verified by digital simulation and by physical tests in an actual LV distribution network. Compared to approaches based only on residual current, the proposed method demonstrates better sensitivity and reliability.
- 14 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (1) , 74-86
Incipient Fault Detection of Medium-Voltage Distribution Cable Systems Using Time-Frequency Analysis of Grounding Wire Currents
Incipient cable faults pose a significant risk to the normal operation of power grids. Addressing the issue of detecting incipient faults in underground cables is particularly difficult due to their hidden external characteristics that are not easily observable. Furthermore, these faults occur randomly, with short durations, which further complicates their detection. This paper firstly establishes a cable field-circuit equivalent model that considers multi-conductor electromagnetic coupling for incipient faulty scenarios. The mathematical relationship between the grounding wire currents (GWCs) and fault conditions is then theoretically deduced specifically. A novel method is developed to detect incipient faults in three-core cables by analyzing the time-frequency characteristics of GWC frequency components considering the time-varying fault resistance. The simulation results demonstrate the effectiveness and robustness of the proposed method, showing little impact from fault initial conditions, disturbances, and distributed generations (DGs). Finally, the method is verified in an actual 10 kV distribution network.
- 14 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (1) , 74-86
Incipient Fault Detection of Medium-Voltage Distribution Cable Systems Using Time-Frequency Analysis of Grounding Wire Currents
Incipient cable faults pose a significant risk to the normal operation of power grids. Addressing the issue of detecting incipient faults in underground cables is particularly difficult due to their hidden external characteristics that are not easily observable. Furthermore, these faults occur randomly, with short durations, which further complicates their detection. This paper firstly establishes a cable field-circuit equivalent model that considers multi-conductor electromagnetic coupling for incipient faulty scenarios. The mathematical relationship between the grounding wire currents (GWCs) and fault conditions is then theoretically deduced specifically. A novel method is developed to detect incipient faults in three-core cables by analyzing the time-frequency characteristics of GWC frequency components considering the time-varying fault resistance. The simulation results demonstrate the effectiveness and robustness of the proposed method, showing little impact from fault initial conditions, disturbances, and distributed generations (DGs). Finally, the method is verified in an actual 10 kV distribution network.