MRI-Based Pressure Gradient Mapping in Patient-Specific Models of Coarctation of the Aorta
Preprint
Abstract
Purpose: Accurate assessment of the pressure gradient ( Δ P ) across aortic coarctation (CoA) is critical for determining disease severity and the need for intervention. Current non-invasive methods are unreliable, while invasive catheterization remains the clinical gold standard. This study evaluates a novel MRI acquisition strategy, 4D-FlowP, that simultaneously encodes blood velocity and acceleration to enable reliable non-invasive pressure gradient mapping in CoA. Methods: Patient-specific compliant aortic phantoms were created from clinical MRI data of two patients with CoA. Additional geometries were synthetically generated by increasing stenosis severity. Phantoms were studied in an MRI-compatible flow loop under physiologically realistic flow and pressure conditions. Pressure gradients were estimated using conventional 4D-Flow MRI, 4D-FlowP, and fluid–structure interaction (FSI) simulations. Results were compared against ground-truth catheter-based measurements across multiple flow rates and stenosis severities. Results: Conventional 4D-Flow consistently underestimated Δ P (slope = 0.63, R 2 =0.75) relative to catheter measurements. In contrast, 4D-FlowP demonstrated substantially improved agreement (slope = 0.95, R 2 =0.75). FSI simulations showed the highest overall agreement with catheter-derived Δ P (slope = 1.14, R 2 =0.82). Scan times for 4D-FlowP were comparable to 4D-Flow (26 vs. 24 minutes). Conclusion: 4D-FlowP enables a more accurate MRI-based pressure gradient mapping in CoA than conventional 4D-Flow, when compared to ground truth catheter measurements. These findings support further in vivo evaluation of 4D-FlowP as a non-invasive alternative for functional assessment of CoA severity.Keywords
This publication has 25 references indexed in Scilit:
- On the Periodicity of Cardiovascular Fluid Dynamics SimulationsAnnals of Biomedical Engineering, 2021
- Quantitative Hemodynamics in Aortic Dissection: Comparing in Vitro MRI with FSI Simulation in a Compliant Model2021
- A gradient optimization toolbox for general purpose time‐optimal MRI gradient waveform designMagnetic Resonance in Medicine, 2020
- SimVascular: An Open Source Pipeline for Cardiovascular SimulationAnnals of Biomedical Engineering, 2016
- MRI‐based computational fluid dynamics for diagnosis and treatment prediction: Clinical validation study in patients with coarctation of aortaJournal of Magnetic Resonance Imaging, 2014
- Non-Invasive Hemodynamic Assessment of Aortic Coarctation: Validation with In Vivo MeasurementsAnnals of Biomedical Engineering, 2012
- 4D flow MRIJournal of Magnetic Resonance Imaging, 2012
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Estimation of relative cardiovascular pressures using time‐resolved three‐dimensional phase contrast MRIMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999