Priya J. Nair
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Priya J. Nair has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Alison L. Marsden
Department of Bioengineering, Stanford University, Stanford, CA, USA
5 shared publications- Daniel B. Ennis
Department of Radiology Stanford University Stanford California USA
5 shared publications - Alison Lesley Marsden
Institute for Computational and Mathematical Engineering, Stanford University, Stanford, USA
4 shared publications Daniel B. Ennis
Department of Radiology, Stanford University , Stanford, CA 94305; , Palo Alto, CA 94304
4 shared publicationsDoff B. McElhinney
Department of Pediatrics—Cardiology, Stanford University , Stanford, CA 94305; , Stanford, CA 94305
4 shared publications- Doff B. McElhinney
Stanford University School of Medicine, Palo Alto, California, USA
4 shared publications
Latest Publications
- Open Access
MRI-Based Pressure Gradient Mapping in Patient-Specific Models of Coarctation of the Aorta
Purpose: Accurate assessment of the pressure gradient ( Δ P ) across aortic coarctation (CoA) is critical for determining disease severity and the need for intervention. Current non-invasive methods are unreliable, while invasive catheterization remains the clinical gold standard. This study evaluates a novel MRI acquisition strategy, 4D-FlowP, that simultaneously encodes blood velocity and acceleration to enable reliable non-invasive pressure gradient mapping in CoA. Methods: Patient-specific compliant aortic phantoms were created from clinical MRI data of two patients with CoA. Additional geometries were synthetically generated by increasing stenosis severity. Phantoms were studied in an MRI-compatible flow loop under physiologically realistic flow and pressure conditions. Pressure gradients were estimated using conventional 4D-Flow MRI, 4D-FlowP, and fluid–structure interaction (FSI) simulations. Results were compared against ground-truth catheter-based measurements across multiple flow rates and stenosis severities. Results: Conventional 4D-Flow consistently underestimated Δ P (slope = 0.63, R 2 =0.75) relative to catheter measurements. In contrast, 4D-FlowP demonstrated substantially improved agreement (slope = 0.95, R 2 =0.75). FSI simulations showed the highest overall agreement with catheter-derived Δ P (slope = 1.14, R 2 =0.82). Scan times for 4D-FlowP were comparable to 4D-Flow (26 vs. 24 minutes). Conclusion: 4D-FlowP enables a more accurate MRI-based pressure gradient mapping in CoA than conventional 4D-Flow, when compared to ground truth catheter measurements. These findings support further in vivo evaluation of 4D-FlowP as a non-invasive alternative for functional assessment of CoA severity.
Open AccessMRI-Based Pressure Gradient Mapping in Patient-Specific Models of Coarctation of the Aorta
Purpose: Accurate assessment of the pressure gradient ( Δ P ) across aortic coarctation (CoA) is critical for determining disease severity and the need for intervention. Current non-invasive methods are unreliable, while invasive catheterization remains the clinical gold standard. This study evaluates a novel MRI acquisition strategy, 4D-FlowP, that simultaneously encodes blood velocity and acceleration to enable reliable non-invasive pressure gradient mapping in CoA. Methods: Patient-specific compliant aortic phantoms were created from clinical MRI data of two patients with CoA. Additional geometries were synthetically generated by increasing stenosis severity. Phantoms were studied in an MRI-compatible flow loop under physiologically realistic flow and pressure conditions. Pressure gradients were estimated using conventional 4D-Flow MRI, 4D-FlowP, and fluid–structure interaction (FSI) simulations. Results were compared against ground-truth catheter-based measurements across multiple flow rates and stenosis severities. Results: Conventional 4D-Flow consistently underestimated Δ P (slope = 0.63, R 2 =0.75) relative to catheter measurements. In contrast, 4D-FlowP demonstrated substantially improved agreement (slope = 0.95, R 2 =0.75). FSI simulations showed the highest overall agreement with catheter-derived Δ P (slope = 1.14, R 2 =0.82). Scan times for 4D-FlowP were comparable to 4D-Flow (26 vs. 24 minutes). Conclusion: 4D-FlowP enables a more accurate MRI-based pressure gradient mapping in CoA than conventional 4D-Flow, when compared to ground truth catheter measurements. These findings support further in vivo evaluation of 4D-FlowP as a non-invasive alternative for functional assessment of CoA severity.
- Open Access
- 4 June 2025
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 147 (7) , 1-16
Experiments and Simulations to Assess Exercise-Induced Pressure Drop Across Aortic Coarctations
Blood pressure gradient (ΔP) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and guide treatment. While invasive cardiac catheterization is the clinical gold-standard for measuring ΔP, it requires anesthesia and does not capture the effects of daily activity or exercise, potentially underestimating the disease's functional burden. This study aimed to identify patients with functionally significant CoA by evaluating exercise-induced ΔP using a hybrid mock circulatory loop (HMCL). Patient-specific aorta geometries (N = 5) of patients with CoA were generated from 4D-Flow magnetic resonance imaging (MRI) scans, then three dimensional (3D)-printed to create compliant aortic phantoms. The phantoms were incorporated into an HMCL with flow and pressure waveforms tuned to patient-specific rest and exercise states. Matched fluid–structure interaction (FSI) simulations were performed using simvascular for comparison. Results showed that mean ΔP increased nonlinearly with cardiac output (CO), with trends differing between patients. HMCL and FSI simulations exhibited excellent agreement in trends of ΔP change with CO, with minimal error of 1.6±1.1 mmHg. This study emphasizes the need for assessing exercise CoA hemodynamics beyond resting ΔP measurements. Overall, HMCLs and FSI simulations enable assessment of patient-specific hemodynamic response to exercise unattainable in clinical practice, thereby facilitating a comprehensive noninvasive assessment of CoA severity. Further, the excellent agreement between HMCL and FSI results indicates that our validated FSI approach can be used independently to assess exercise CoA hemodynamics hereafter, eliminating the need for repeated complex HMCL experiments.
- 4 June 2025
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 147 (7) , 1-16
Open AccessExperiments and Simulations to Assess Exercise-Induced Pressure Drop Across Aortic Coarctations
Blood pressure gradient (ΔP) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and guide treatment. While invasive cardiac catheterization is the clinical gold-standard for measuring ΔP, it requires anesthesia and does not capture the effects of daily activity or exercise, potentially underestimating the disease's functional burden. This study aimed to identify patients with functionally significant CoA by evaluating exercise-induced ΔP using a hybrid mock circulatory loop (HMCL). Patient-specific aorta geometries (N = 5) of patients with CoA were generated from 4D-Flow magnetic resonance imaging (MRI) scans, then three dimensional (3D)-printed to create compliant aortic phantoms. The phantoms were incorporated into an HMCL with flow and pressure waveforms tuned to patient-specific rest and exercise states. Matched fluid–structure interaction (FSI) simulations were performed using simvascular for comparison. Results showed that mean ΔP increased nonlinearly with cardiac output (CO), with trends differing between patients. HMCL and FSI simulations exhibited excellent agreement in trends of ΔP change with CO, with minimal error of 1.6±1.1 mmHg. This study emphasizes the need for assessing exercise CoA hemodynamics beyond resting ΔP measurements. Overall, HMCLs and FSI simulations enable assessment of patient-specific hemodynamic response to exercise unattainable in clinical practice, thereby facilitating a comprehensive noninvasive assessment of CoA severity. Further, the excellent agreement between HMCL and FSI results indicates that our validated FSI approach can be used independently to assess exercise CoA hemodynamics hereafter, eliminating the need for repeated complex HMCL experiments.
- 4 December 2024
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 16 (1) , 138-153
Assessing the Impact of Cardiac Output and Valve Orientation on Bioprosthetic Pulmonary Valve Hemodynamics Using In Vitro 4D-Flow MRI and High-Speed Imaging
Purpose Pulmonary valve replacement (PVR) using bioprosthetic valves is a common procedure performed in patients with repaired Tetralogy of Fallot and other conditions, but these valves frequently become dysfunctional within 15 years of implantation. The causes for early valve failure are not clearly understood. The purpose of this study was to explore the impact of changing cardiac output (CO) and valve orientation on local hemodynamics and valve performance. Methods A 25 mm bioprosthetic valve was implanted in an idealized 3D-printed model of the right ventricular outflow tract (RVOT). The local hemodynamics at three COs and two valve orientations were assessed using 4D-Flow MRI and high-speed camera imaging. Results Noticeable differences in jet asymmetry, the amount of recirculation, leaflet opening patterns, as well as the size and location of reversed flow regions were observed with varying CO. Rotation of the valve resulted in drastic differences in reversed flow regions, but not forward flow. Conclusion Flow features observed in the valve with low CO in this study have previously been correlated with calcification, hemolysis, and leaflet fatigue, indicating their potential negative impact on local hemodynamics and leaflet performance.
- 4 December 2024
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 16 (1) , 138-153
Assessing the Impact of Cardiac Output and Valve Orientation on Bioprosthetic Pulmonary Valve Hemodynamics Using In Vitro 4D-Flow MRI and High-Speed Imaging
Purpose Pulmonary valve replacement (PVR) using bioprosthetic valves is a common procedure performed in patients with repaired Tetralogy of Fallot and other conditions, but these valves frequently become dysfunctional within 15 years of implantation. The causes for early valve failure are not clearly understood. The purpose of this study was to explore the impact of changing cardiac output (CO) and valve orientation on local hemodynamics and valve performance. Methods A 25 mm bioprosthetic valve was implanted in an idealized 3D-printed model of the right ventricular outflow tract (RVOT). The local hemodynamics at three COs and two valve orientations were assessed using 4D-Flow MRI and high-speed camera imaging. Results Noticeable differences in jet asymmetry, the amount of recirculation, leaflet opening patterns, as well as the size and location of reversed flow regions were observed with varying CO. Rotation of the valve resulted in drastic differences in reversed flow regions, but not forward flow. Conclusion Flow features observed in the valve with low CO in this study have previously been correlated with calcification, hemolysis, and leaflet fatigue, indicating their potential negative impact on local hemodynamics and leaflet performance.
- Open Access
Experiments and Simulations to Assess Exercise-Induced Pressure Drop Across Aortic Coarctations
Blood pressure gradient (ΔP) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and guide treatment. While invasive cardiac catheterization is the clinical gold-standard for measuring ΔP, it requires anesthesia and does not capture the effects of daily activity or exercise, potentially underestimating the disease's functional burden. This study aimed to identify patients with functionally significant CoA by evaluating exercise-induced ΔP using a hybrid mock circulatory loop (HMCL). Patient-specific aorta geometries (N=5) of patients with CoA were generated from 4D-Flow magnetic resonance imaging (MRI) scans, then 3D-printed to create compliant aortic phantoms. The phantoms were incorporated into an HMCL with flow and pressure waveforms tuned to patient-specific rest and exercise states. Matched fluid-structure interaction (FSI) simulations were performed using SimVascular for comparison. Results showed that mean ΔP increased non-linearly with cardiac output (CO), with trends differing between patients. HMCL and FSI simulations exhibited excellent agreement in trends of ΔP change with CO, with minimal error of 1.6 ± 1.1 mmHg. This study emphasizes the need for assessing exercise CoA hemodynamics beyond resting ΔP measurements. Overall, HMCLs and FSI simulations enable assessment of patient-specific hemodynamic response to exercise unattainable in clinical practice, thereby facilitating a comprehensive non-invasive assessment of CoA severity. Further, the excellent agreement between HMCL and FSI results indicates that our validated FSI approach can be used independently to assess exercise CoA hemodynamics
Open AccessExperiments and Simulations to Assess Exercise-Induced Pressure Drop Across Aortic Coarctations
Blood pressure gradient (ΔP) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and guide treatment. While invasive cardiac catheterization is the clinical gold-standard for measuring ΔP, it requires anesthesia and does not capture the effects of daily activity or exercise, potentially underestimating the disease's functional burden. This study aimed to identify patients with functionally significant CoA by evaluating exercise-induced ΔP using a hybrid mock circulatory loop (HMCL). Patient-specific aorta geometries (N=5) of patients with CoA were generated from 4D-Flow magnetic resonance imaging (MRI) scans, then 3D-printed to create compliant aortic phantoms. The phantoms were incorporated into an HMCL with flow and pressure waveforms tuned to patient-specific rest and exercise states. Matched fluid-structure interaction (FSI) simulations were performed using SimVascular for comparison. Results showed that mean ΔP increased non-linearly with cardiac output (CO), with trends differing between patients. HMCL and FSI simulations exhibited excellent agreement in trends of ΔP change with CO, with minimal error of 1.6 ± 1.1 mmHg. This study emphasizes the need for assessing exercise CoA hemodynamics beyond resting ΔP measurements. Overall, HMCLs and FSI simulations enable assessment of patient-specific hemodynamic response to exercise unattainable in clinical practice, thereby facilitating a comprehensive non-invasive assessment of CoA severity. Further, the excellent agreement between HMCL and FSI results indicates that our validated FSI approach can be used independently to assess exercise CoA hemodynamics
- Open Access
Assessing the Impact of Valve Sizing and Orientation on Bioprosthetic Pulmonary Valve Hemodynamics Using In Vitro 4D-Flow MRI
Purpose Pulmonary valve replacement (PVR) using bioprosthetic valves is a common procedure performed in patients with repaired Tetralogy of Fallot and other conditions, but these valves frequently become dysfunctional within 15 years of implantation. Since PVR is often performed in adolescence, valves are typically oversized to account for somatic growth. However, the contribution of oversizing to early valve failure are not clearly understood. The purpose of this study was to explore the impact of valve sizing and orientation on local hemodynamics and valve performance. Methods Different valve sizes were represented by changing the cardiac output through a 25 mm bioprosthetic valve implanted in an idealized 3D-printed model of the right ventricular outflow tract (RVOT). The local hemodynamics at three valve sizes and two valve orientations were assessed using 4D-Flow MRI and high-speed camera imaging. Results Noticeable differences in jet asymmetry, the amount of recirculation, leaflet opening patterns, as well as the size and location of reversed flow regions were observed with varying valve sizes. Rotation of the valve resulted in drastic differences in reversed flow regions, but not forward flow. Conclusion Flow features observed in the oversized valve in this study have previously been correlated with calcification, hemolysis, and leaflet fatigue. Therefore, valve oversizing can negatively impact local hemodynamics and leaflet performance.
Open AccessAssessing the Impact of Valve Sizing and Orientation on Bioprosthetic Pulmonary Valve Hemodynamics Using In Vitro 4D-Flow MRI
Purpose Pulmonary valve replacement (PVR) using bioprosthetic valves is a common procedure performed in patients with repaired Tetralogy of Fallot and other conditions, but these valves frequently become dysfunctional within 15 years of implantation. Since PVR is often performed in adolescence, valves are typically oversized to account for somatic growth. However, the contribution of oversizing to early valve failure are not clearly understood. The purpose of this study was to explore the impact of valve sizing and orientation on local hemodynamics and valve performance. Methods Different valve sizes were represented by changing the cardiac output through a 25 mm bioprosthetic valve implanted in an idealized 3D-printed model of the right ventricular outflow tract (RVOT). The local hemodynamics at three valve sizes and two valve orientations were assessed using 4D-Flow MRI and high-speed camera imaging. Results Noticeable differences in jet asymmetry, the amount of recirculation, leaflet opening patterns, as well as the size and location of reversed flow regions were observed with varying valve sizes. Rotation of the valve resulted in drastic differences in reversed flow regions, but not forward flow. Conclusion Flow features observed in the oversized valve in this study have previously been correlated with calcification, hemolysis, and leaflet fatigue. Therefore, valve oversizing can negatively impact local hemodynamics and leaflet performance.
- 10 February 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (5) , 1-12
Non-invasive Estimation of Pressure Drop Across Aortic Coarctations: Validation of 0D and 3D Computational Models with In Vivo Measurements
Blood pressure gradient (\(\Delta P\)) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of \(\Delta P\) estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N = 17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. \(\Delta P\) across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. The 0D simulations were extremely efficient (\(\sim\) 15 s computation time) compared to 3D simulations (\(\sim\) 30 h computation time on a cluster). However, the 0D \(\Delta P\) estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as \(\Delta P\) \(\ge\) 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.- 10 February 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (5) , 1-12
Non-invasive Estimation of Pressure Drop Across Aortic Coarctations: Validation of 0D and 3D Computational Models with In Vivo Measurements
Blood pressure gradient (\(\Delta P\)) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of \(\Delta P\) estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N = 17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. \(\Delta P\) across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. The 0D simulations were extremely efficient (\(\sim\) 15 s computation time) compared to 3D simulations (\(\sim\) 30 h computation time on a cluster). However, the 0D \(\Delta P\) estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as \(\Delta P\) \(\ge\) 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.- Open Access
Non-invasive estimation of pressure drop across aortic coarctations: validation of 0D and 3D computational models with in vivo measurements
Purpose: Blood pressure gradient ( Δ P) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of Δ P estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Methods: Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N=17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. Δ P across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. Results: The 0D simulations were extremely efficient ( ∼ 15 secs computation time) compared to 3D simulations ( ∼ 30 hrs computation time on a cluster). However, the 0D Δ P estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as Δ P ≥ 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Conclusion: Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.
Open AccessNon-invasive estimation of pressure drop across aortic coarctations: validation of 0D and 3D computational models with in vivo measurements
Purpose: Blood pressure gradient ( Δ P) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of Δ P estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Methods: Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N=17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. Δ P across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. Results: The 0D simulations were extremely efficient ( ∼ 15 secs computation time) compared to 3D simulations ( ∼ 30 hrs computation time on a cluster). However, the 0D Δ P estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as Δ P ≥ 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Conclusion: Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.
- 16 June 2023
- Published by Springer Nature
- p. 515-523
Hemodynamics in Patients with Aortic Coarctation: A Comparison of in vivo 4D-Flow MRI and FSI Simulation
- 16 June 2023
- Published by Springer Nature
- p. 515-523
Hemodynamics in Patients with Aortic Coarctation: A Comparison of in vivo 4D-Flow MRI and FSI Simulation
- Open Access
Hemodynamics in Patients with Aortic Coarctation: A Comparison of in vivo 4D-Flow MRI and FSI Simulation
The analysis of quantitative hemodynamics provides information for the diagnosis and treatment planning in patients with aortic coarctation (CoA). Patient-specific computational fluid dynamics (CFD) simulations reveal detailed hemodynamic information, but their agreement with the clinical standard 4D-Flow magnetic resonance imaging (MRI) needs to be characterized. This work directly compares in vivo CFD fluid-structure interaction (FSI) simulations against 4D-Flow MRI in patients with CoA (N=5). 4D-Flow MRI-derived flow waveforms and cuff blood pressure measurements were used to tune the boundary conditions for the FSI simulations. Flow rates from 4D-Flow MRI and FSI were compared at cross-sections in the ascending aorta (AAo), CoA and descending aorta (DAo). Qualitative comparisons showed an overall agreement of flow patterns in the aorta between the two methods. The R 2 values for the flow waveforms in the AAo, CoA, and DAo were 0.97, 0.84 and 0.81 respectively, representing a strong correlation between 4DFlow MRI measurements and FSI results. This work characterizes the use of patient-specific FSI simulations in quantifying and analyzing CoA hemodynamics to inform CoA treatment planning.
Open AccessHemodynamics in Patients with Aortic Coarctation: A Comparison of in vivo 4D-Flow MRI and FSI Simulation
The analysis of quantitative hemodynamics provides information for the diagnosis and treatment planning in patients with aortic coarctation (CoA). Patient-specific computational fluid dynamics (CFD) simulations reveal detailed hemodynamic information, but their agreement with the clinical standard 4D-Flow magnetic resonance imaging (MRI) needs to be characterized. This work directly compares in vivo CFD fluid-structure interaction (FSI) simulations against 4D-Flow MRI in patients with CoA (N=5). 4D-Flow MRI-derived flow waveforms and cuff blood pressure measurements were used to tune the boundary conditions for the FSI simulations. Flow rates from 4D-Flow MRI and FSI were compared at cross-sections in the ascending aorta (AAo), CoA and descending aorta (DAo). Qualitative comparisons showed an overall agreement of flow patterns in the aorta between the two methods. The R 2 values for the flow waveforms in the AAo, CoA, and DAo were 0.97, 0.84 and 0.81 respectively, representing a strong correlation between 4DFlow MRI measurements and FSI results. This work characterizes the use of patient-specific FSI simulations in quantifying and analyzing CoA hemodynamics to inform CoA treatment planning.