Chemical Resolution of Pu+ from U+ and Am+ Using a Band-Pass Reaction Cell Inductively Coupled Plasma Mass Spectrometer
Authors:
- 4 May 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (11) , 3042-3048
Abstract
Determination of the concentration and distribution of the Pu and Am isotopes is hindered by the isobaric overlaps between the elements themselves and U, generally requiring time-consuming chemical separation of the elements. A method is described in which chemical resolution of the elemental ions is obtained through ion−molecule reactions in a reaction cell of an ICPMS instrument. The reactions of “natural” U+, 242Pu+, and 243Am+ with ethylene, carbon dioxide, and nitric oxide are reported. Since the net sensitivities to the isotopes of an element are similar, chemical resolution is inferred when one isobaric element reacts rapidly with a given gas and the isobar (or in this instance surrogate isotope) is unreactive or slowly reactive. Chemical resolution of the m/z 238 isotopes of U and Pu can be obtained using ethylene as a reaction gas, but little improvement in the resolution of the m/z 239 isobars is obtained. However, high efficiency of reaction of U+ and UH+ with CO2, and nonreaction of Pu+, allows the sub-ppt determination of 239Pu, 240Pu, and 242Pu (single ppt for 238Pu) in the presence of 7 orders of magnitude excess U matrix without prior chemical separation. Similarly, oxidation of Pu+ by NO, and nonreaction of Am+, permit chemical resolution of the isobars of Pu and Am over 2−3 orders of magnitude relative concentration. The method provides the potential for analysis of the actinides with reduced sample matrix separation.Keywords
This publication has 15 references indexed in Scilit:
- Reaction cells and collision cells for ICP-MS: a tutorial reviewSpectrochimica Acta Part B: Atomic Spectroscopy, 2002
- Gas-Phase Oxidation Reactions of Neptunium and Plutonium Ions Investigated via Fourier Transform Ion Cyclotron Resonance Mass SpectrometryThe Journal of Physical Chemistry A, 2002
- Gas-phase chemistry of actinide ions: probing the distinctive character of the 5f elementsInternational Journal of Mass Spectrometry, 2002
- Characteristics and capabilities of an ICP-MS with a dynamic reaction cell for dry aerosols and laser ablationJournal of Analytical Atomic Spectrometry, 2000
- A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS)Journal of Analytical Atomic Spectrometry, 1999
- High resolution inductively coupled plasma mass spectrometry for the trace determination of plutonium isotopes and isotope ratios in environmental samplesJournal of Analytical Atomic Spectrometry, 1998
- A Comparative Study of Oxo‐Ligand Effects in the Gas‐Phase Chemistry of Atomic Lanthanide and Actinide CationsChemistry – A European Journal, 1997
- Determination of long-lived radioisotopes using electrothermal vaporization–inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1996
- Development of a high-sensitivity inductively coupled plasma mass spectrometer for actinide measurement in the femtogram rangeJournal of Analytical Atomic Spectrometry, 1996
- Hydride interference on the determination of minor actinide isotopes by inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1994