Scott D. Tanner
Research Subjects
Research Interests
Scott D. Tanner has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Vladimir I. Baranov
PerkinElmer SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada, and Radiation Protection Bureau, Health Canada, Ottawa, Ontario K1A 1C1, Canada
2 shared publicationsChunsheng Li
PerkinElmer SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada, and Radiation Protection Bureau, Health Canada, Ottawa, Ontario K1A 1C1, Canada
1 shared publicationDmitry R. Bandura
PerkinElmer SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada, and Radiation Protection Bureau, Health Canada, Ottawa, Ontario K1A 1C1, Canada
1 shared publication- Dmitry R. Bandura
Institute of Biomaterials and Biomedical Engineering, University of Toronto, Room 407, 164 College Street, Toronto, Ontario, Canada M5S 3G9
1 shared publication Vladimir Vais
PerkinElmer SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada, and Radiation Protection Bureau, Health Canada, Ottawa, Ontario K1A 1C1, Canada
1 shared publicationZoë A. Quinn
MDS SCIEX, 71 Four Valley Drive, Concord, Ontario, Canada
1 shared publication
Latest Publications
- 4 May 2004
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (11) , 3042-3048
Chemical Resolution of Pu+ from U+ and Am+ Using a Band-Pass Reaction Cell Inductively Coupled Plasma Mass Spectrometer
Determination of the concentration and distribution of the Pu and Am isotopes is hindered by the isobaric overlaps between the elements themselves and U, generally requiring time-consuming chemical separation of the elements. A method is described in which chemical resolution of the elemental ions is obtained through ion−molecule reactions in a reaction cell of an ICPMS instrument. The reactions of “natural” U+, 242Pu+, and 243Am+ with ethylene, carbon dioxide, and nitric oxide are reported. Since the net sensitivities to the isotopes of an element are similar, chemical resolution is inferred when one isobaric element reacts rapidly with a given gas and the isobar (or in this instance surrogate isotope) is unreactive or slowly reactive. Chemical resolution of the m/z 238 isotopes of U and Pu can be obtained using ethylene as a reaction gas, but little improvement in the resolution of the m/z 239 isobars is obtained. However, high efficiency of reaction of U+ and UH+ with CO2, and nonreaction of Pu+, allows the sub-ppt determination of 239Pu, 240Pu, and 242Pu (single ppt for 238Pu) in the presence of 7 orders of magnitude excess U matrix without prior chemical separation. Similarly, oxidation of Pu+ by NO, and nonreaction of Am+, permit chemical resolution of the isobars of Pu and Am over 2−3 orders of magnitude relative concentration. The method provides the potential for analysis of the actinides with reduced sample matrix separation.
- 4 May 2004
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (11) , 3042-3048
Chemical Resolution of Pu+ from U+ and Am+ Using a Band-Pass Reaction Cell Inductively Coupled Plasma Mass Spectrometer
Determination of the concentration and distribution of the Pu and Am isotopes is hindered by the isobaric overlaps between the elements themselves and U, generally requiring time-consuming chemical separation of the elements. A method is described in which chemical resolution of the elemental ions is obtained through ion−molecule reactions in a reaction cell of an ICPMS instrument. The reactions of “natural” U+, 242Pu+, and 243Am+ with ethylene, carbon dioxide, and nitric oxide are reported. Since the net sensitivities to the isotopes of an element are similar, chemical resolution is inferred when one isobaric element reacts rapidly with a given gas and the isobar (or in this instance surrogate isotope) is unreactive or slowly reactive. Chemical resolution of the m/z 238 isotopes of U and Pu can be obtained using ethylene as a reaction gas, but little improvement in the resolution of the m/z 239 isobars is obtained. However, high efficiency of reaction of U+ and UH+ with CO2, and nonreaction of Pu+, allows the sub-ppt determination of 239Pu, 240Pu, and 242Pu (single ppt for 238Pu) in the presence of 7 orders of magnitude excess U matrix without prior chemical separation. Similarly, oxidation of Pu+ by NO, and nonreaction of Am+, permit chemical resolution of the isobars of Pu and Am over 2−3 orders of magnitude relative concentration. The method provides the potential for analysis of the actinides with reduced sample matrix separation.
- 18 June 2002
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (9) , 1148-1152
The potential for elemental analysis in biotechnology
The ICP-MS brings particular attributes to the method that distinguishes it from organic mass spectrometry: relative insensitivity to concomitant organic or metallic species, equivalent sensitivity to all similarly-tagged complexes, inherent ability to provide absolute quantitation and linearity of response. All these positive features fit the requirements of modern-day biotechnology. In this work, the potential of ICP-MS is discussed in the context of several urgent problems of biotechnology including: the determination of the state of phosphorylation of proteins, quality control of biologically active materials and control of efficiency of cell line transfections.
- 18 June 2002
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (9) , 1148-1152
The potential for elemental analysis in biotechnology
The ICP-MS brings particular attributes to the method that distinguishes it from organic mass spectrometry: relative insensitivity to concomitant organic or metallic species, equivalent sensitivity to all similarly-tagged complexes, inherent ability to provide absolute quantitation and linearity of response. All these positive features fit the requirements of modern-day biotechnology. In this work, the potential of ICP-MS is discussed in the context of several urgent problems of biotechnology including: the determination of the state of phosphorylation of proteins, quality control of biologically active materials and control of efficiency of cell line transfections.