Purpose: To test whether a 3D imaging sequence with phase contrast (PC) velocity encoding based on steady‐state free precession (SSFP) improves 3D velocity quantification in the heart compared to the currently available gradient echo (GE) approach.Materials and Methods: The 3D PC‐SSFP sequence with 1D velocity encoding was compared at the mitral valve in 12 healthy subjects with 3D PC‐GE at 1.5T. Velocity measurements, velocity‐to‐noise‐ratio efficiency (VNReff), intra‐ and interobserver variability of area and velocity measurements, contrast‐to‐noise‐ratio (CNR), and artifact sensitivity were evaluated in both long‐ and short‐axis orientation.Results: Descending aorta mean and peak velocities correlated well (r2 = 0.79 and 0.93) between 3D PC‐SSFP and 3D PC‐GE. At the mitral valve, mean velocity correlation was moderate (r2 = 0.70 short axis, 0.56 long axis) and peak velocity showed good correlation (r2 = 0.94 short axis, 0.81 long axis). In some cases VNReff was higher, in others lesser, depending on slab orientation and cardiac phase. Intra‐ and interobserver variability was generally better for 3D PC‐SSFP. CNR improved significantly, especially at end systole. Artifact levels did not increase.Conclusion: 3D SSFP velocity quantification was successfully tested in the heart. Blood‐myocardium contrast improved significantly, resulting in more reproducible velocity measurements for 3D PC‐SSFP at 1.5T. J. Magn. Reson. Imaging 2009;30:947–955.Keywords
This publication has 37 references indexed in Scilit:
- Inflow quantification in three‐dimensional cardiovascular MR imagingJournal of Magnetic Resonance Imaging, 2008
- Flow Measurement by Magnetic Resonance: A Unique Asset Worth OptimisingJournal of Cardiovascular Magnetic Resonance, 2007
- Flow compensation in balanced SSFP sequencesMagnetic Resonance in Medicine, 2005
- On flow effects in balanced steady‐state free precession imaging: Pictorial description, parameter dependence, and clinical implicationsJournal of Magnetic Resonance Imaging, 2004
- Markl M, et al. Time Resolved Three Dimensional Phase Contrast MRI. Journal of Magn Reson Imaging 2003;17:499–506.Journal of Magnetic Resonance Imaging, 2003
- Time‐resolved three‐dimensional phase‐contrast MRIJournal of Magnetic Resonance Imaging, 2003
- Single‐breathhold 3D‐trueFISP cine cardiac imagingMagnetic Resonance in Medicine, 2002
- Use of an intravascular T1 contrast agent to improve MR cine myocardial‐blood pool definition in manJournal of Magnetic Resonance Imaging, 1997
- An analysis of fast imaging sequences with steady‐state transverse magnetization refocusingMagnetic Resonance in Medicine, 1988
- In Vivo Validation of MR Velocity ImagingJournal of Computer Assisted Tomography, 1987