Ceramic-on-Ceramic Total Hip Arthroplasty: Incidence of Instability and Noise
- 1 February 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (2) , 437-442
Abstract
Questions/purposes We determined generation of squeaking and the relationship between squeaking and component position. Methods We prospectively entered 436 alumina-on-alumina, cementless, primary THAs in 364 patients into our institutional database. All procedures were performed with the same surgical technique and the same implant. We obtained Harris Hip scores and a noise questionnaire and assessed radiographic component position and loosening. We determined the difference in abduction angle between squeakers and nonsqueakers. Minimum followup was 2 years (average, 3.5 years; range, 2.0-6.2 years). Results The mean Harris hip score increased from 51.9 preoperatively to 94.4 at latest followup. Six hips underwent reoperation: four hips (1.1%) for dislocation and two (0.53%) for periprosthetic fracture after trauma. The incidence of noise of any type was 11%, with the most common type of noise being clicking or snapping. Squeaking was reported by 1.9% of patients, with no patient being revised for this phenomenon. We found no association between component position and squeaking. Conclusions At average 3 years followup, 98% of ceramic-on-ceramic THAs did not require a revision, with 1.1% of hips having been revised for dislocation. Fewer than 2% of patients reported hearing an audible squeak, with no association found between component position and squeaking. Level of Evidence Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence....Keywords
This publication has 33 references indexed in Scilit:
- The 2009 Frank Stinchfield Award: “Hip Squeaking”Clinical Orthopaedics and Related Research, 2010
- Ceramic-on-ceramic bearing surface and risk of revision due to dislocation after primary total hip replacementThe Journal of Bone and Joint Surgery. British volume, 2009
- Reproducibility and Accuracy of Templating Uncemented THA With Digital Radiographic and Digital TraumaCad Templating SoftwareOrthopedics, 2009
- Squeaking HipsJournal of Bone and Joint Surgery, 2008
- High Incidence of Squeaking in THAs with Alumina Ceramic-on-ceramic BearingsClinical Orthopaedics and Related Research, 2008
- Ceramic-on-Ceramic Total Hip Arthroplasty Early Dislocation RateClinical Orthopaedics and Related Research, 2007
- Influence of Total Hip Design on DislocationClinical Orthopaedics and Related Research, 2006
- Alumina Ceramic Bearings for Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2005
- Wear and Periprosthetic OsteolysisClinical Orthopaedics and Related Research, 2001
- Evolution of Alumina-on-Alumina ImplantsClinical Orthopaedics and Related Research, 2000