Short Implants: A Descriptive Study of 273 Implants
Authors:
- Xavier Costa‐BerenguerXCXavier Costa‐Berenguer
- Cosme Gay‐EscodaCGCosme Gay‐Escoda
- 26 October 2010
- journal article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 14 (4) , 508-516
Abstract
Purpose: The study aims to assess the performance of short implants in a series of patients with severe alveolar resorption.Materials and Methods: A review is made of 273 implants measuring 10 mm or less, placed by conventional surgery or using osteotomes, and with a postloading follow‐up of between 18 months and 12 years (mean 81 months).Results: A total of 20 failures were recorded (7.33%), with a global implant survival of 92.67%. The survival rate for 10 mm implants was 92.82%, versus 92.5% in the case of those measuring less than 10 mm. Overall, the failure rate was lowest for the treated surface implants (2.56% vs 4.76%). On considering the implants measuring under 10 mm, the failure rates were similar in both groups (3.77%).Conclusions: Short implants are a good treatment alternative for patients with severe alveolar resorption of both jaws.Keywords
This publication has 15 references indexed in Scilit:
- Influence of Diameter and Length of Implant on Early Dental Implant FailureJournal of Oral and Maxillofacial Surgery, 2010
- Maxillary sinus floor elevation using the (transalveolar) osteotome technique with or without grafting material. Part I: implant survival and patients' perceptionClinical Oral Implants Research, 2009
- Five‐Year Clinical Evaluation of Short Dental Implants Placed in Posterior Areas: A Retrospective StudyJournal of Periodontology, 2008
- Augmentation procedures for the rehabilitation of deficient edentulous ridges with oral implantsClinical Oral Implants Research, 2006
- Impact of implant length and diameter on survival ratesClinical Oral Implants Research, 2006
- Performance of Short Implants in Partial Restorations: 3-Year Follow-up of Osseotite® ImplantsImplant Dentistry, 2005
- A Targeted Review of Study Outcomes With Short (≤7 mm) Endosseous Dental Implants Placed in Partially Edentulous PatientsJournal of Periodontology, 2004
- Success and Failure Rates of 9 mm or Shorter Implants in the Replacement of Missing Maxillary Molars When Restored with Individual Crowns: Preliminary Results 0 to 84 Months in Function. A Retrospective StudyJournal of Periodontology, 2004
- Early Functional Loading of Brånemark Dental Implants: 5‐Year Clinical Follow‐up StudyClinical Implant Dentistry and Related Research, 2000
- Implant‐retained mandibular overdentures with immediate loadingClinical Oral Implants Research, 1997