Accuracy of Image-Guided Surgical Systems at the Lateral Skull Base as Clinically Assessed Using Bone-Anchored Hearing Aid Posts as Surgical Targets
- 1 December 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 29 (8) , 1050-1055
Abstract
Objective: Image-guided surgical (IGS) technology has been clinically available for more than a decade. To date, no acceptable standard exists for reporting the accuracy of IGS systems, especially for lateral skull base applications. We present a validation method that uses the post from bone-anchored hearing aid (BAHA) patients as a target. We then compare the accuracy of 2 IGS systems-one using laser skin-surface scanning (LSSS) and another using a noninvasive fiducial frame (FF) attached to patient via dental bite-block (DBB) for registration. Study Design: Prospective. Setting: Tertiary referral center. Patients: Six BAHA patients who had adequate dentition for creation of a DBB. Intervention(s): For each patient, a dental impression was obtained, and a customized DBB was made to hold an FF. Temporal bone computed tomographic (CT) scans were obtained with the patient wearing the DBB, FF, and a customized marker on the BAHA post. In a mock operating room, CT scans were registered to operative anatomy using 2 methods: 1) LSSS and 2) FF. Main Outcome Measure(s): For each patient and each system, the position of the BAHA marker in the CT scan and in the mock operating room (using optical measurement technology) was compared, and the distances between them are reported to demonstrate accuracy. Results: Accuracy (mean ± standard deviation) was 1.54 ± 0.63 mm for DBB registration and 3.21 ± 1.02 mm for LSSS registration. Conclusion: An IGS system using FF registration is more accurate than one using LSSS (p = 0.03, 2-sided Student's t test). BAHA patients provide a unique patient population upon which IGS systems may be validated.Keywords
This publication has 17 references indexed in Scilit:
- OR 2020: The Operating Room of the FutureJournal of Laparoendoscopic & Advanced Surgical Techniques, 2005
- In vitro assessment of image‐guided otologic surgery: Submillimeter accuracy within the region of the temporal boneOtolaryngology–Head and Neck Surgery, 2005
- Submillimetric target-registration error using a novel, non-invasive fiducial system for image-guided otologic surgeryComputer Aided Surgery, 2004
- Registration Accuracy and Practicability of Laser-Directed Surface MatchingComputer Aided Surgery, 2002
- Registration accuracy and practicability of laser-directed surface matchingComputer Aided Surgery, 2002
- Fiducial Point Placement and the Accuracy of Point-based, Rigid Body RegistrationNeurosurgery, 2001
- The distribution of target registration error in rigid-body point-based registrationIEEE Transactions on Medical Imaging, 2001
- Efficacy of Computed Tomographic Image–Guided Endoscopic Sinus Surgery in Residency Training ProgramsThe Laryngoscope, 2000
- Current neurosurgical management and the impact of the extent of resection in the treatment of malignant gliomas of childhood: a report of the Children's Cancer Group Trial No. CCG-945Journal of Neurosurgery, 1998
- Registration of head volume images using implantable fiducial markersIEEE Transactions on Medical Imaging, 1997