Yujie Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yujie Yang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Dong Sun
Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
3 shared publications - Libo Zhao
School of Instrument Science and Technology, Xi’an Jiaotong University, Xi’an, China
3 shared publications - Wendi Gao
Department of Gastroenterology, Second Affiliated Hospital of Xi'an Jiaotong University 4 , Xi'an, and , Xi'an 710049
3 shared publications - Wenji Cui
Department of Gastroenterology, the Second Affiliated Hospital, Xian Jiaotong University, Xian 710004, China, also with the State Key Laboratory for Manufacturing Systems Engineering, the State Industry-Education Integration Center for Medical Innovations, the International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, and the School of Instrument Science and Technology
2 shared publications Dehua Liu
Department of Gastroenterology, Second Affiliated Hospital, Xian Jiaotong University, Xian, China
1 shared publication- Dehua Liu
Xi’an Jiaotong University
1 shared publication
Latest Publications
- 28 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-13
Automated and Near-Flawless Micropipette PIH Assembly to MEMS Nanoforce Sensor With A Robotic Microscopy System
Peg-in-hole (PIH) assembly of micropipettes to micro-electromechanical system (MEMS) nanoforce sensors can be performed to improve spatial probing resolution and operation space, but their spatial attitude angle deviations and off-axial distances lead to unstable assembly, sensor performance deterioration, and even structural damage. In this article, an automated and near-flawless micropipette PIH assembly method was proposed based on the built robotic microscopy system, to the best of our knowledge, for the first time. Utilizing an ISPR-based method with a mechanical equilibrium model and a sliding mode controller, the planar deflection angle was adjusted below 0.07 ${}^{\boldsymbol{\circ}}$ without being pushed out of FOV. The out-of-plane inclination angle was then reduced to below 0.05 ${}^{\boldsymbol{\circ}}$ by the proposed GTC-based method, whose depth is obtained from a feasible FDTBR inclination metrology and mechanical contact model. The off-axial distance was actively adjusted by an AIHM-based recenter method during sensor probe insertion, leading to a high assembly successful rate of 100% with negligible contact forces of 1.64 ${\boldsymbol{\mu}}$ N. The methodology effectiveness was validated through calibration tests, wherein no structural damage and performance deterioration were produced on the processed sensor for a long-term usage, indicating its great potential in nanoforce measurement.
- 28 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-13
Automated and Near-Flawless Micropipette PIH Assembly to MEMS Nanoforce Sensor With A Robotic Microscopy System
Peg-in-hole (PIH) assembly of micropipettes to micro-electromechanical system (MEMS) nanoforce sensors can be performed to improve spatial probing resolution and operation space, but their spatial attitude angle deviations and off-axial distances lead to unstable assembly, sensor performance deterioration, and even structural damage. In this article, an automated and near-flawless micropipette PIH assembly method was proposed based on the built robotic microscopy system, to the best of our knowledge, for the first time. Utilizing an ISPR-based method with a mechanical equilibrium model and a sliding mode controller, the planar deflection angle was adjusted below 0.07 ${}^{\boldsymbol{\circ}}$ without being pushed out of FOV. The out-of-plane inclination angle was then reduced to below 0.05 ${}^{\boldsymbol{\circ}}$ by the proposed GTC-based method, whose depth is obtained from a feasible FDTBR inclination metrology and mechanical contact model. The off-axial distance was actively adjusted by an AIHM-based recenter method during sensor probe insertion, leading to a high assembly successful rate of 100% with negligible contact forces of 1.64 ${\boldsymbol{\mu}}$ N. The methodology effectiveness was validated through calibration tests, wherein no structural damage and performance deterioration were produced on the processed sensor for a long-term usage, indicating its great potential in nanoforce measurement.
- 14 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP (10834435) , 1-12
A Biaxial MEMS Capacitive Nanoforce Sensor Based on a Novel Bistable Bioinspired Swallow Structure for Somatic Cell Micromanipulation
Precise measurement of ultralow biaxial forces at the nano-Newton (nN) level is highly demanded for robotic micromanipulation of somatic cells. A novel microelectromechanical system capacitive nanoforce sensor was proposed to address this demand. Inspired by the stable gliding gestures of a swallow, a bistable swallow structure was introduced, offering high deformation flexibility with negligible mechanical cross-axis coupling. Considering its mechanical behaviors, a comb configuration and interconnection strategy were proposed to eliminate internal electrostatic coupling rotation. The fabricated sensor was packaged with a time-division multiplexing-based readout circuit, comprising a compact measurement system. The x-axis force sensitivity reached 0.9893 fF/nN, with a high resolution of 0.3658 nN and a linearity of 0.9994 over a range of 8.02 μN. Besides, the y-axis force sensitivity reached 0.2683 fF/nN, with a resolution of 0.8244 nN and a linearity of 0.9995 over a range of 8.11 μN. The noise floor was lower than 0.0665 nN/$\sqrt {\mathbf{Hz}} $ and 0.1688 nN/$\sqrt {\mathbf{Hz}} $ for x- and y-axes, respectively, and the cross-axis coupling error ratios were only 0.15% and 0.36%, respectively. The proposed sensor was adopted to manipulate mouse myoblast cells, allowing nN-level biaxial interaction force responses to be measured in real-time robotic manipulation for the first time.
- 14 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP (10834435) , 1-12
A Biaxial MEMS Capacitive Nanoforce Sensor Based on a Novel Bistable Bioinspired Swallow Structure for Somatic Cell Micromanipulation
Precise measurement of ultralow biaxial forces at the nano-Newton (nN) level is highly demanded for robotic micromanipulation of somatic cells. A novel microelectromechanical system capacitive nanoforce sensor was proposed to address this demand. Inspired by the stable gliding gestures of a swallow, a bistable swallow structure was introduced, offering high deformation flexibility with negligible mechanical cross-axis coupling. Considering its mechanical behaviors, a comb configuration and interconnection strategy were proposed to eliminate internal electrostatic coupling rotation. The fabricated sensor was packaged with a time-division multiplexing-based readout circuit, comprising a compact measurement system. The x-axis force sensitivity reached 0.9893 fF/nN, with a high resolution of 0.3658 nN and a linearity of 0.9994 over a range of 8.02 μN. Besides, the y-axis force sensitivity reached 0.2683 fF/nN, with a resolution of 0.8244 nN and a linearity of 0.9995 over a range of 8.11 μN. The noise floor was lower than 0.0665 nN/$\sqrt {\mathbf{Hz}} $ and 0.1688 nN/$\sqrt {\mathbf{Hz}} $ for x- and y-axes, respectively, and the cross-axis coupling error ratios were only 0.15% and 0.36%, respectively. The proposed sensor was adopted to manipulate mouse myoblast cells, allowing nN-level biaxial interaction force responses to be measured in real-time robotic manipulation for the first time.