Calvin Abonga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Calvin Abonga has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Michael A. Suster
Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH, USA
2 shared publications - Pedram Mohseni
Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH, USA
2 shared publications - Christopher A. Delianides
Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH
1 shared publication - Hanif Alizadeh
Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH, USA
1 shared publication - Payam Fadaei
Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH, USA
1 shared publication - Sina Pourang
Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH, USA
1 shared publication
Latest Publications
- Open Access
- 2 October 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (23) , 6256-6267
Evaluating anti-sickling therapies for sickle cell disease: a microfluidic assay for red blood cell-mediated microvascular occlusion under hypoxia
This study establishes the chemically induced hypoxia OcclusionChip assay as a reliable clinical tool for evaluating red blood cell deformability in sickle cell disease, with potential to improve personalized treatment strategies and outcomes.
- 2 October 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (23) , 6256-6267
Open AccessEvaluating anti-sickling therapies for sickle cell disease: a microfluidic assay for red blood cell-mediated microvascular occlusion under hypoxia
This study establishes the chemically induced hypoxia OcclusionChip assay as a reliable clinical tool for evaluating red blood cell deformability in sickle cell disease, with potential to improve personalized treatment strategies and outcomes.
- 3 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (7) , 1-4
Contact Activation in Dielectric Blood Coagulometry: A Comparison of Screen-Printed and Sputtered Gold Electrodes of ClotChip Microfluidic Sensor
This paper investigates the effect of surface roughness on the kinetics of whole blood coagulation through a comparative study of two different electrode fabrication techniques, screen-printing and sputtering, for a microfluidic dielectric sensor termed ClotChip. Featuring a three-dimensional, parallel-plate, capacitive sensing structure with gold sensing and floating electrodes deposited on polymethyl methacrylate plastic substrates, we have previously shown that ClotChip can measure the temporal variation in the normalized real permittivity of a coagulating whole blood sample (peak ) readout parameter. In this work, scanning electron microscope imaging and profilometry measurements reveal that the surface of the sputtered-gold electrode is much smoother than the rough surface of its screen-printed counterpart, having a mean arithmetic average height and root mean square roughness of ∼ 38.0 nm and 47.0 nm versus 5.7 μm and 7.2 μm for the screen-printed electrode. The ClotChip Tpeak parameter has also been measured for both untreated whole blood samples and those modified in vitro with corn trypsin inhibitor, an inhibitor of the activated coagulation factor XII (FXIIa) used to suppress surface-induced coagulation by contact activation. Our results establish that surface-induced, FXIIa-mediated contact activation plays a more prominent role in accelerating the kinetics of whole blood coagulation for rough screen-printed electrodes than for smooth sputtered electrodes.
- 3 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (7) , 1-4
Contact Activation in Dielectric Blood Coagulometry: A Comparison of Screen-Printed and Sputtered Gold Electrodes of ClotChip Microfluidic Sensor
This paper investigates the effect of surface roughness on the kinetics of whole blood coagulation through a comparative study of two different electrode fabrication techniques, screen-printing and sputtering, for a microfluidic dielectric sensor termed ClotChip. Featuring a three-dimensional, parallel-plate, capacitive sensing structure with gold sensing and floating electrodes deposited on polymethyl methacrylate plastic substrates, we have previously shown that ClotChip can measure the temporal variation in the normalized real permittivity of a coagulating whole blood sample (peak ) readout parameter. In this work, scanning electron microscope imaging and profilometry measurements reveal that the surface of the sputtered-gold electrode is much smoother than the rough surface of its screen-printed counterpart, having a mean arithmetic average height and root mean square roughness of ∼ 38.0 nm and 47.0 nm versus 5.7 μm and 7.2 μm for the screen-printed electrode. The ClotChip Tpeak parameter has also been measured for both untreated whole blood samples and those modified in vitro with corn trypsin inhibitor, an inhibitor of the activated coagulation factor XII (FXIIa) used to suppress surface-induced coagulation by contact activation. Our results establish that surface-induced, FXIIa-mediated contact activation plays a more prominent role in accelerating the kinetics of whole blood coagulation for rough screen-printed electrodes than for smooth sputtered electrodes.