Intraoperative six-axis loads during direct anterior approach total hip arthroplasty using a leg positioner: quantitative patterns across manoeuvres
- 21 September 2026
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (12) , 3171-3179
Abstract
Purpose The direct anterior approach (DAA) for total hip arthroplasty (THA) commonly uses leg positioners to facilitate femoral exposure, but intraoperative lower-limb loading during these manoeuvres remains poorly understood. This study quantitatively assessed six-axis loads during femoral preparation in leg positioner-assisted DAA-THA. Methods This prospective observational biomechanical study included 95 hips undergoing primary DAA-THA using a leg positioner. A six-axis force sensor mounted on the operative boot recorded forces (Fx, Fy, Fz) and moments (Mx, My, Mz) at baseline and at two predefined static endpoint measurement points: the extension endpoint and the final stem position after adduction. Values were expressed relative to baseline and represented static endpoint measurements rather than peak values during dynamic manoeuvres. Measurements were standardised to a right-sided coordinate system. Repeated-measures analysis of variance with Bonferroni-corrected post hoc paired comparisons was used. Results At the extension endpoint, distal traction force was greatest (Fz; 170.6 ± 51.9 N). At the final stem position after adduction, distal traction force decreased compared with the extension endpoint but remained elevated relative to baseline (126.9 ± 45.7 N), and Mx showed the greatest magnitude among the moment components. The maximum endpoint Fz relative to baseline was recorded at the extension endpoint (322.8 N). No significant associations were found between final-position Fz and age, sex, height, weight, body mass index, or diagnosis. Mean stem rasping time was 10 min 48 s ± 4 min 28 s (648 ± 268 s). Conclusion During leg positioner-assisted DAA-THA, the extension endpoint generated the highest distal traction force, whereas the final stem position after adduction was associated with residual distal traction force and a greater magnitude of Mx.Keywords
This publication has 33 references indexed in Scilit:
- Direct anterior total hip arthroplasty with dual mobility cup for femoral neck fractures in dementia patientsSICOT-J, 2025
- Is There a Learning Curve for the 5-Year Implant Survival Rate of Total Hip Arthroplasty Using the Direct Anterior Approach With a Traction Table? A Prospective Cohort StudyThe Journal of Arthroplasty, 2024
- Motor Nerve Palsy After Direct Anterior Versus Posterior Total Hip Arthroplasty: Incidence, Risk Factors, and RecoveryThe Journal of Arthroplasty, 2023
- Direct anterior approach total hip arthroplasty with an orthopedic traction tableOperative Orthopädie und Traumatologie, 2021
- Use of Dual Mobility Acetabular Component and Anterior Approach in Patients With Displaced Femoral Neck FractureThe Journal of Arthroplasty, 2021
- Pelvic mobility before and after total hip arthroplastyInternational Orthopaedics, 2020
- Total hip arthroplasty via the direct anterior approach with a dual mobility cup for displaced femoral neck fracture in patients with a high risk of dislocationSICOT-J, 2017
- Prospective study of nerve injuries associated with hip arthroscopy in the lateral position using the modified portalsJournal of Hip Preservation Surgery, 2016
- Biomechanical stability of tape augmentation for anterior talofibular ligament (ATFL) repair compared to the native ATFLKnee Surgery, Sports Traumatology, Arthroscopy, 2016
- Functional and Mechanical Evaluation of Nerve Stretch InjuryJournal of Medical Systems, 2010