A dual stage wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals
Authors:
- Cinthya L Toledo-PeralCTCinthya L Toledo-Peral
- Gabriel Vega-MartínezGVGabriel Vega-Martínez
- Ximena Romero-GómezXRXimena Romero-Gómez
- Jesús Fausto Córdova-ManzoJCJesús Fausto Córdova-Manzo
- Jorge Airy Mercado-GutierrezJMJorge Airy Mercado-Gutierrez
- Arturo Vera-HernándezAVArturo Vera-Hernández
- Israel Ramírez-SánchezIRIsrael Ramírez-Sánchez
- Sonia Patricia Romano-RiquerSRSonia Patricia Romano-Riquer
- 1 June 2026
- journal article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 035056
Abstract
Motion artifacts in functional near-infrared spectroscopy (fNIRS) signals can distort reflected light waveforms and affect derived physiological estimates. This study presents a dual stage, joint ROI guided wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals from the PhysioNet database Motion Artifact Contaminated fNIRS and EEG Data . The method combines continuous wavelet transform based joint ROI detection across the 690 and 830 nm signals with local dual threshold discrete wavelet correction and smooth boundary blending. Performance was assessed by mean squared error (MSE) within artifact contaminated ROIs and by root mean square error (RMSE) of a ratio based oxygen saturation estimate relative to the clean reference channel. Compared with spline-Savitzky–Golay and global dual threshold wavelet benchmarks, the proposed workflow achieved the lowest estimate domain RMSE in five of nine trials. These findings support joint ROI guided local wavelet correction as a competitive strategy for preserving ratio derived reflected light estimates in this dataset.Keywords
This publication has 25 references indexed in Scilit:
- Non-invasive SpO2 Monitoring Using Reflective PPG: A Low-Cost Calibration Method2023
- A non-contact oxygen saturation detection method based on dynamic spectrumInfrared Physics & Technology, 2022
- Investigation of Confounding Factors in Measuring Tissue Saturation with NIRS Spatially Resolved Spectroscopy2018
- Self-Calibration Phenomenon for Near-Infrared Clinical Measurements: Theory, Simulation, and ExperimentsACS Omega, 2018
- Multisite Near Infrared Spectroscopy During Cardiopulmonary Bypass in Pediatric PatientsArtificial Organs, 2015
- fNIRS in the developmental sciencesWIREs Cognitive Science, 2015
- A Methodology for Validating Artifact Removal Techniques for Physiological SignalsIEEE Transactions on Information Technology in Biomedicine, 2012
- Wavelet based motion artifact removal for Functional Near Infrared Spectroscopy2010
- Quality control and assurance in functional near infrared spectroscopy (fNIRS) experimentationPhysics in Medicine & Biology, 2010
- Motion Artifact Removal for Functional Near Infrared Spectroscopy: A Comparison of MethodsIEEE Transactions on Biomedical Engineering, 2010