Jesús Fausto Córdova-Manzo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jesús Fausto Córdova-Manzo has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Arturo Vera
Electrical Engineering Department, Bioelectronics Section, Center for Research and Advanced Studies of the National Polytechnic Institute CINVESTAV-IPN, Mexico City 07360, Mexico
3 shared publications - Abraham Hernández-Jiménez
Communications Section, Electrical Engineering Department, Cinvestav, CDMX
2 shared publications - Adolfo López-Liévano
Universidad Veracruzana
2 shared publications - Felipe Mendoza-González
Universidad Veracruzana
2 shared publications - Gabriel Vega-Martínez
Instituto Nacional de Rehabilitación Luis Guillermo Ibarra Ibarra
2 shared publications - Jesús Fausto Córdova-Escobedo
Universidad Veracruzana
2 shared publications
Latest Publications
- 1 June 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 035056
A dual stage wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals
Motion artifacts in functional near-infrared spectroscopy (fNIRS) signals can distort reflected light waveforms and affect derived physiological estimates. This study presents a dual stage, joint ROI guided wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals from the PhysioNet database Motion Artifact Contaminated fNIRS and EEG Data . The method combines continuous wavelet transform based joint ROI detection across the 690 and 830 nm signals with local dual threshold discrete wavelet correction and smooth boundary blending. Performance was assessed by mean squared error (MSE) within artifact contaminated ROIs and by root mean square error (RMSE) of a ratio based oxygen saturation estimate relative to the clean reference channel. Compared with spline-Savitzky–Golay and global dual threshold wavelet benchmarks, the proposed workflow achieved the lowest estimate domain RMSE in five of nine trials. These findings support joint ROI guided local wavelet correction as a competitive strategy for preserving ratio derived reflected light estimates in this dataset.
- 1 June 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 035056
A dual stage wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals
Motion artifacts in functional near-infrared spectroscopy (fNIRS) signals can distort reflected light waveforms and affect derived physiological estimates. This study presents a dual stage, joint ROI guided wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals from the PhysioNet database Motion Artifact Contaminated fNIRS and EEG Data . The method combines continuous wavelet transform based joint ROI detection across the 690 and 830 nm signals with local dual threshold discrete wavelet correction and smooth boundary blending. Performance was assessed by mean squared error (MSE) within artifact contaminated ROIs and by root mean square error (RMSE) of a ratio based oxygen saturation estimate relative to the clean reference channel. Compared with spline-Savitzky–Golay and global dual threshold wavelet benchmarks, the proposed workflow achieved the lowest estimate domain RMSE in five of nine trials. These findings support joint ROI guided local wavelet correction as a competitive strategy for preserving ratio derived reflected light estimates in this dataset.
- 16 May 2025
- Published by Springer Nature
- p. 204-214
Bioinstrumentation Amplifier with Band-Pass Differential Filter Using Impedance Converter for Electrocardiography Signals
- 16 May 2025
- Published by Springer Nature
- p. 204-214
Bioinstrumentation Amplifier with Band-Pass Differential Filter Using Impedance Converter for Electrocardiography Signals
- Open Access
- 1 January 2025
- Published by Wiley in Journal of Sensors
- Vol. 2025 (1)
Near‐Infrared Spectroscopy for Noninvasive Bladder Evaluation: Systematic Review and Future Directions
Near‐infrared spectroscopy (NIRS) is an optical method that can be utilized to measure changes in oxygenation and hemodynamics in human tissues. Numerous studies have been published on NIRS, but many of them are not aimed at urological rehabilitation applications, especially bladder monitoring (BM). A systematic literature review (SLR) was prepared for this research using the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses (PRISMA) methodology. Excluded papers were more than 5 years old, duplicated, or unrelated to urological rehabilitation applications. Among all the research, over 1800 studies referred to other bladder conditions such as cancer applications. Of the remaining papers, only 16 studies were focused on NIRS BM. Of them, 25.00% refer to wearable devices, 31.25% to noninvasive optical techniques, and 43.75% to advanced diagnostic tools. Of the seven advanced diagnostic tools articles, five combined NIRS with other methods like uroflowmetry, and two focused on NIRS alone. Despite some limitations, several studies emphasize the importance of NIRS and the potential of its related technologies in the monitoring and management of bladder dysfunctions, offering noninvasive and patient‐friendly solutions. Consequently, clinical trial studies to establish the effectiveness and reliability of NIRS in various patient populations are warranted to enhance the clinical utility and patient outcomes of NIRS‐based BM systems.
- 1 January 2025
- Published by Wiley in Journal of Sensors
- Vol. 2025 (1)
Open AccessNear‐Infrared Spectroscopy for Noninvasive Bladder Evaluation: Systematic Review and Future Directions
Near‐infrared spectroscopy (NIRS) is an optical method that can be utilized to measure changes in oxygenation and hemodynamics in human tissues. Numerous studies have been published on NIRS, but many of them are not aimed at urological rehabilitation applications, especially bladder monitoring (BM). A systematic literature review (SLR) was prepared for this research using the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses (PRISMA) methodology. Excluded papers were more than 5 years old, duplicated, or unrelated to urological rehabilitation applications. Among all the research, over 1800 studies referred to other bladder conditions such as cancer applications. Of the remaining papers, only 16 studies were focused on NIRS BM. Of them, 25.00% refer to wearable devices, 31.25% to noninvasive optical techniques, and 43.75% to advanced diagnostic tools. Of the seven advanced diagnostic tools articles, five combined NIRS with other methods like uroflowmetry, and two focused on NIRS alone. Despite some limitations, several studies emphasize the importance of NIRS and the potential of its related technologies in the monitoring and management of bladder dysfunctions, offering noninvasive and patient‐friendly solutions. Consequently, clinical trial studies to establish the effectiveness and reliability of NIRS in various patient populations are warranted to enhance the clinical utility and patient outcomes of NIRS‐based BM systems.
- Open Access
- 31 December 2022
- Published by ECORFAN in Revista de Desarrollo Urbano y Sustentable
- p. 18-30
Program for Sustainable Designs of led lighting systems
Computer Program made in MATLAB that allows sustainable designs of lighting systems with Led lamps for different user requirements. The program requires as data the dimensions, reflectance, cavities and the desired lighting level of the work area to be illuminated and the type of LED luminaire to be used. The calculations are carried out in a deterministic, precise and exact way, using the lumens method and the Official Mexican Standard for lighting designs. The program provides information such as the total number of luminaires to be used, the calculated lux level, the electrical power density, among others, as well as a graph that indicates an adequate design for the accommodation and distribution of the lamps in the work area to be illuminated. , complying with the Lighting Design Standards. The program correctly performs each of the calculations and at the end delivers the most suitable design for the accommodation of the lamps and their distances. Correct lighting means achieving an optimal balance between human needs, architectural considerations and energy efficiency.
- 31 December 2022
- Published by ECORFAN in Revista de Desarrollo Urbano y Sustentable
- p. 18-30
Open AccessProgram for Sustainable Designs of led lighting systems
Computer Program made in MATLAB that allows sustainable designs of lighting systems with Led lamps for different user requirements. The program requires as data the dimensions, reflectance, cavities and the desired lighting level of the work area to be illuminated and the type of LED luminaire to be used. The calculations are carried out in a deterministic, precise and exact way, using the lumens method and the Official Mexican Standard for lighting designs. The program provides information such as the total number of luminaires to be used, the calculated lux level, the electrical power density, among others, as well as a graph that indicates an adequate design for the accommodation and distribution of the lamps in the work area to be illuminated. , complying with the Lighting Design Standards. The program correctly performs each of the calculations and at the end delivers the most suitable design for the accommodation of the lamps and their distances. Correct lighting means achieving an optimal balance between human needs, architectural considerations and energy efficiency.
- Open Access
- 31 December 2022
- Published by ECORFAN in Journal of Technological Prototypes
- p. 1-10
Medical gas monitoring design applying image processing
Design of a methodology, that uses image processing to monitor the pressure indicators of medical gas tanks (oxygen and nitrogen) used in hospitals to care for patients who require it. This system can notify the pressure level reported by the indicators and its contribution is the application of technology that prevents the displacement of medical or technical personnel to the gas installations, resulting in a remote monitoring system.
- 31 December 2022
- Published by ECORFAN in Journal of Technological Prototypes
- p. 1-10
Open AccessMedical gas monitoring design applying image processing
Design of a methodology, that uses image processing to monitor the pressure indicators of medical gas tanks (oxygen and nitrogen) used in hospitals to care for patients who require it. This system can notify the pressure level reported by the indicators and its contribution is the application of technology that prevents the displacement of medical or technical personnel to the gas installations, resulting in a remote monitoring system.