Israel Ramírez-Sánchez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Israel Ramírez-Sánchez has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Arturo Vera
Electrical Engineering Department, Bioelectronics Section, Center for Research and Advanced Studies of the National Polytechnic Institute CINVESTAV-IPN, Mexico City 07360, Mexico
1 shared publication - Cinthya Lourdes Toledo Peral
Instituto Nacional de Rehabilitación Luis Guillermo Ibarra Ibarra
1 shared publication - Gabriel Vega-Martínez
Instituto Nacional de Rehabilitación Luis Guillermo Ibarra Ibarra
1 shared publication - Jesús Fausto Córdova-Manzo
Universidad Veracruzana
1 shared publication - Jorge Airy Mercado-Gutierrez
Instituto Nacional de Rehabilitación Luis Guillermo Ibarra Ibarra
1 shared publication - Sonia Patricia Romano-Riquer
Instituto Nacional de Rehabilitación Luis Guillermo Ibarra Ibarra
1 shared publication
Latest Publications
- 1 June 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 035056
A dual stage wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals
Motion artifacts in functional near-infrared spectroscopy (fNIRS) signals can distort reflected light waveforms and affect derived physiological estimates. This study presents a dual stage, joint ROI guided wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals from the PhysioNet database Motion Artifact Contaminated fNIRS and EEG Data . The method combines continuous wavelet transform based joint ROI detection across the 690 and 830 nm signals with local dual threshold discrete wavelet correction and smooth boundary blending. Performance was assessed by mean squared error (MSE) within artifact contaminated ROIs and by root mean square error (RMSE) of a ratio based oxygen saturation estimate relative to the clean reference channel. Compared with spline-Savitzky–Golay and global dual threshold wavelet benchmarks, the proposed workflow achieved the lowest estimate domain RMSE in five of nine trials. These findings support joint ROI guided local wavelet correction as a competitive strategy for preserving ratio derived reflected light estimates in this dataset.
- 1 June 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 035056
A dual stage wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals
Motion artifacts in functional near-infrared spectroscopy (fNIRS) signals can distort reflected light waveforms and affect derived physiological estimates. This study presents a dual stage, joint ROI guided wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals from the PhysioNet database Motion Artifact Contaminated fNIRS and EEG Data . The method combines continuous wavelet transform based joint ROI detection across the 690 and 830 nm signals with local dual threshold discrete wavelet correction and smooth boundary blending. Performance was assessed by mean squared error (MSE) within artifact contaminated ROIs and by root mean square error (RMSE) of a ratio based oxygen saturation estimate relative to the clean reference channel. Compared with spline-Savitzky–Golay and global dual threshold wavelet benchmarks, the proposed workflow achieved the lowest estimate domain RMSE in five of nine trials. These findings support joint ROI guided local wavelet correction as a competitive strategy for preserving ratio derived reflected light estimates in this dataset.