Fatigue testing of a self-compression screw model in Pauwels III fracture: an in vitro analysis
Authors:
- Anderson FreitasAFAnderson Freitas
- Vincenzo GiordanoVincenzo Giordano
- Edvalson Francisco Neves JuniorEJEdvalson Francisco Neves Junior
- Paulo Alves TavaresPTPaulo Alves Tavares
- Robison Esteves PiresRPRobison Esteves Pires
- William Dias BelangeroWBWilliam Dias Belangero
- Pedro José LabroniciPLPedro José Labronici
- 13 June 2025
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-9
Abstract
Purpose Femoral neck fractures (FNFs) have become increasingly common among young adults as a result of high-energy trauma. Despite the variety of implants available for the surgical treatment of FNFs, compelling evidence of clinically uniform outcome is lacking, and high complication rates are still reported. In this scenario, it seems reasonable to investigate novel implants and surgical, especially in Pauwels type III (PIII) FNFs. The objective of this study was to describe the fatigue test results of a construct using the self-compression screw model (X-PIN + P) in PIII FNFs within a validated synthetic bone model. Methods Sawbones® composite femurs were divided into three groups corresponding to 40% (G40 (n = 4)), 50% (G50 (n = 4)), and 70% (G70 (n = 2)) of the mean load values. The test termination endpoints were catastrophic failure (CF) of the construct, displacement of 10 mm, or reaching 500,000 cycles (C500). The variables analysed were the number of cycles up to 5 mm of displacement (C5 mm), total number of cycles up to termination endpoints (TC), and the mode of CF. Results In the G40, the test was terminated due to C500 in three specimens and CF in one specimen (peri-implant subtrochanteric fracture with main screw breakage). The test was terminated due to CF in all models in G50 (peri-implant subtrochanteric fracture without screw breakage in three specimens, and varus collapse of the femoral head in one specimen) and in G70 (femoral head fracture without screw breakage in both specimens). Conclusion In vitro fatigue bench testing of the self-compression screw model X-PIN + P in PIII FNFs yield satisfactory numerical results regarding test termination due to the limit total number of cycles (500,000). Catastrophic failures were more frequently observed in the G50 and G70 after supraphysiologic loads, mainly characterized by a subtrochanteric femur fracture.Keywords
This publication has 28 references indexed in Scilit:
- In vitro biomechanical analysis of a locking self-compression screw model applied to Pauwels III and comminuted femoral neck fracturesInjury, 2023
- Femoral neck fracture in a young person – ORIF but do we use a medial buttress plate as well on the femoral neck?Injury, 2022
- Neck of femur fractures treated with the femoral neck system: outcomes of one hundred and two patients and literature reviewInternational Orthopaedics, 2022
- Proposal for a New Fixation Method for Pauwels Type III Femoral Neck Fracture-Metaphyseal Stem: A Finite-Element AnalysisIndian Journal of Orthopaedics, 2021
- Stability of L-shaped and inverted triangle fixation assemblies in treating Pauwels type II femoral neck fracture: a comparative mechanical studyEuropean Journal of Orthopaedic Surgery & Traumatology, 2018
- Femoral neck fracture osteosynthesis by the biplane double-supported screw fixation method (BDSF) reduces the risk of fixation failure: clinical outcomes in 207 patientsArchives of orthopaedic and trauma surgery, 2017
- Application of a medial buttress plate may prevent many treatment failures seen after fixation of vertical femoral neck fractures in young adultsMedical Hypotheses, 2015
- Biomechanical rationale for implant choices in femoral neck fracture fixation in the non-elderlyInjury, 2015
- Biomechanical analysis of a novel femoral neck locking plate for treatment of vertical shear Pauwel's type C femoral neck fracturesInjury, 2012
- Mechanical validation of whole bone composite femur modelsJournal of Biomechanics, 1996