PLPedro José Labronici

Pedro José Labronici

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pedro José Labronici has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Posterolateral plating increases peroneal tendon thickness without affecting clinical outcomes: a ultrasonographic comparative study of 76 SER ankle fractures

    by Pedro José Labronici, Jonas Pessoa de Campos, João Pedro de Araújo Almeida, William Dias Belangero, Gustavo Waldolato, Robinson Esteves Pires, Antônio Tufi Neder Filho, Túlio Vinícius de Oliveira Campos, David Rojas, Anderson Freitas, et al.

    Objectives: To evaluate, using ultrasonography and the AOFAS (The American Orthopaedic Foot and Ankle Society) score, changes in the peroneal tendons of patients with ankle fractures resulting from a supination-external rotation (SER) mechanism treated with either lateral or posterolateral plate fixation. Methods: This retrospective observational study was conducted at a tertiary level III trauma center. Adult patients (> 18 years) with unilateral SER ankle fractures, a minimum follow-up of 1 year, no persistent symptoms, and fixation using a 1/3 tubular 3.5-mm locking plate (lateral or posterolateral) were included. Exclusion criteria comprised bilateral injuries, Weber A/C fractures, pathological fractures, previous ankle disorders, infection, postoperative pain, or functional limitations. The primary outcomes were peroneal tendon thickness on ultrasonography and functional performance assessed using the AOFAS Ankle-Hindfoot Scale. Outcomes were compared between fixation techniques. Results: Seventy-six patients were included (65.8% aged 35–64 years, 60.5% women, 53.9% left-sided injuries). In most cases (71.1%), tendon thickness was greater on the operated side. Posterolateral plating demonstrated a higher frequency of positive tendon-thickness differences. Most differences measured 0–2 mm (56.6%), with a statistically significant difference between lateral and posterolateral fixation groups ( p < 0.001). AOFAS scores were high in both groups, indicating satisfactory postoperative functional outcomes. Conclusions: A difference in peroneal tendon thickness between the operated and contralateral sides was observed in 89.5% of patients, and these differences were significantly greater after posterolateral plating. Although plate position directly influenced postoperative tendon thickness, no clinically relevant consequences were identified. Level of evidence: Level III.

  • Open Access

    Should We Worry About the Inter-Implant Gap in the Tibia? A Finite Element Analysis of Revision TKA and Distal Plating

    by Renato Caravellos Glória, Pedro José Labronici, Anderson Freitas, Vincenzo Giordano

    Background and Objectives: The management of periprosthetic tibial fractures distal to revision Total Knee Arthroplasty (TKA) presents a biomechanical challenge, often requiring extramedullary locking plates when long stems preclude nailing. While in femoral fractures the gap between the stem and plate is a well-documented stress riser, requiring implant overlap to prevent an inter-implant fracture, this specific biomechanical scenario has not been studied in the tibia, and it remains unclear if the femoral dogma of mandatory overlap applies to the straight, centrically loaded tibial anatomy. This study utilized Finite Element Analysis (FEA) to evaluate stress distribution in the tibial inter-implant gap. Materials and Methods: A comparative FEA was performed using a validated standardized tibia model simulating a healed distal fracture. Two cemented revision TKA constructs (50 mm and 80 mm stems) were modeled. These were paired with medial locking plates of varying lengths (10, 12, and 14 holes) to create different inter-implant distances. Eight distinct configurations, including non-plated controls, were subjected to physiological axial compression and three-point bending. Outcome measures included von Mises stress and total displacement. Results: The analysis revealed no significant stress concentration in the bone within the inter-implant zone across all plated models, regardless of the gap size. Instead, the addition of plates universally reduced bone stress compared to controls, effectively transferring load to the fixation hardware. Peak stresses were consistently observed in the proximal locking screws rather than the bone gap. The longest plates (14 holes) offered superior construct rigidity and stress distribution. Conclusions: Under the conditions evaluated in this preclinical finite element model, the tibia does not exhibit a biomechanical requirement for implant overlap to prevent stress risers. Our findings suggest that extramedullary fixation with the longest available anatomical locking plate represents a biomechanically plausible strategy for these fractures, even if an inter-implant gap remains.

  • Fatigue testing of a self-compression screw model in Pauwels III fracture: an in vitro analysis

    by Anderson Freitas, Vincenzo Giordano, Edvalson Francisco Neves Junior, Paulo Alves Tavares, Robison Esteves Pires, William Dias Belangero, Pedro José Labronici

    Purpose Femoral neck fractures (FNFs) have become increasingly common among young adults as a result of high-energy trauma. Despite the variety of implants available for the surgical treatment of FNFs, compelling evidence of clinically uniform outcome is lacking, and high complication rates are still reported. In this scenario, it seems reasonable to investigate novel implants and surgical, especially in Pauwels type III (PIII) FNFs. The objective of this study was to describe the fatigue test results of a construct using the self-compression screw model (X-PIN + P) in PIII FNFs within a validated synthetic bone model. Methods Sawbones® composite femurs were divided into three groups corresponding to 40% (G40 (n = 4)), 50% (G50 (n = 4)), and 70% (G70 (n = 2)) of the mean load values. The test termination endpoints were catastrophic failure (CF) of the construct, displacement of 10 mm, or reaching 500,000 cycles (C500). The variables analysed were the number of cycles up to 5 mm of displacement (C5 mm), total number of cycles up to termination endpoints (TC), and the mode of CF. Results In the G40, the test was terminated due to C500 in three specimens and CF in one specimen (peri-implant subtrochanteric fracture with main screw breakage). The test was terminated due to CF in all models in G50 (peri-implant subtrochanteric fracture without screw breakage in three specimens, and varus collapse of the femoral head in one specimen) and in G70 (femoral head fracture without screw breakage in both specimens). Conclusion In vitro fatigue bench testing of the self-compression screw model X-PIN + P in PIII FNFs yield satisfactory numerical results regarding test termination due to the limit total number of cycles (500,000). Catastrophic failures were more frequently observed in the G50 and G70 after supraphysiologic loads, mainly characterized by a subtrochanteric femur fracture.


  • Is surgical treatment better than non-surgical treatment for proximal humeral fracture in elderly people? A meta-analysis and meta-regression

    by Paulo Roberto Hernandes Júnior, Thiago Alves Garcia, Renato de Oliveira Caravellos Glória, Gustavo Waldolato, André Luis Lugnani de Andrade, Pedro José Labronici, William Dias Belangero

    Purpose This systematic review, meta-analysis, and meta-regression aims to determine whether surgical treatment for proximal humeral fractures is superior to non-surgical treatment regarding pain, functionality, complications, and new surgery rates. Methods We systematically reviewed clinical trials from PubMed (MEDLINE), EMBASE, Web of Science, Scopus, and Cochrane up to April 2024. Data comparing surgical or conservative of proximal humeral fractures were retrieved for outcomes of pain, functionality, adverse events, and new surgeries. We conducted meta-analyses and meta-regressions using average age as the independent variable (x-axis) and the main outcomes as the dependent variable (y-axis). For all analyses, a p value lower than 0.05 was considered statistically significant. Results Thirteen articles were included in the final analysis, with most follow-up times occurring at 3, 4, 6, 12, and 24 months. The surgical interventions included ORIF, conventional arthroplasty or reversed. Significant differences favoring of surgery were found for functionality at 6 months (SMD = − 0.238; 95% CI − 0.381 to − 0.096, p = 0.001), and for Constant score at 12 months (RMD = − 4.077; 95% CI − 7.034 to − 1.120, p = 0.007). Subgroup analysis showed significant results favoring arthroplasty at 12 months for the Constant score (RMD = − 4.563; 95% CI − 8.104 to − 1.023, p = 0.012). Meta-analysis for complications indicated that the surgery group had significantly higher odds of complications (OR 4.20; 95% CI 2.054–8.591, p < 0.001). The occurrence of osteonecrosis showed no difference between the surgical and conservative groups (OR 0.57; 95% CI 0.167–2.012, p = 0.390). The odds ratio of reoperation were five times higher in the surgical group (OR 5.31; 95% CI 2.467–11.430, p < 0.001). Meta-regressions demonstrated a significant relationship between age and pain, functionality and quality of life at 12-months, with worse results in the conservative group as age increased. Conclusion The findings indicate a beneficial effect of surgery for proximal humeral fractures, but only for functionality scores at specific time points. However, the reoperation and complication rates were higher in the surgical group. With increasing age, the outcomes tend to be worse for the conservative group. Level of evidence 1A Systematic review of RCTs


  • Open Access

    Biomechanical Efficacy of Three Methods for the Fixation of Posterior Malleolar Fractures: A Three-Dimensional Finite Element Study

    by Vincenzo Giordano, Márcio Antônio Babinski, Anderson Freitas, Robinson Esteves Pires, Felipe Serrão de Souza, Luiz Paulo Giorgetta de Faria, Pedro José Labronici, Alexandre Godoy-Santos

    Introduction: We investigated the biomechanical behaviour of different fixations of the tibial posterior malleolus (TPM), simulating distinct situations of involvement of the tibiotalar articular surface (TTAS) through a finite element model (FEM). Material and methods: A 3D computer-aided design model of the left ankle was obtained. The materials used were divided according to their characteristics into ductile and non-ductile, and all materials were assumed to be linear elastic, isotropic, and homogenous. Three different fracture lines of the TPM were defined, with sagittal angles of 10°, 25°, and 45°. For biomechanical comparison, different constructions using a trans-syndesmotic screw (TSS) only (Group T), a one-third tubular plate only with (Group PT) and without (Group PS) a TSS, and a locked compression plate with (Group LCPT) and without (Group LCPS) a TSS were tested. FEM was used to simulate the boundary conditions of vertical loading. Load application regions were selected in the direction of the 700 N Z-axis, 90% on the tibia and 10% on the fibula. Data on the displacement and stress in the FEM were collected, including the total principal maximum (MaxT) and total principal minimum (MinT) for non-ductile materials, total displacement (desT), localized displacement at the fragment (desL), localized displacement at syndesmosis (desS), and Von Mises equivalent stress for ductile materials. The data were analysed using ANOVA and multiple comparison LSD tests were used. Results: For TPM fractures with sagittal angles 10° and 25°, desL in the PT and LCP groups was significantly lower, as well as Von Mises stress in Group LCPT in 10°, and PT and LCPT groups in 25°. For TPM fractures with a sagittal angle of 45°, desL in the LCP group and Von Mises stress in Group LCPS and LCPT were significantly lower. We found that any TPM fracture may indicate instability of the distal tibiofibular syndesmosis, even when the fragment is small. Conclusion: Our study showed that in fragments involving 10% of the TTAS, the use of a TSS is sufficient, but when the involvement is greater than 25% of the TTAS, either a non-locked or locked plate must be used to buttress the TPM. In posterior fragments affecting 45% or more of the TTAS, the use of a locking plate is recommended.


  • Open Access

    Biomechanical Efficacy of Three Methods for the Fixation of Posterior Malleolar Fractures: A Three-Dimensional Finite Element Study

    by Vincenzo Giordano, Márcio Antônio Babinski, Anderson Freitas, Robinson Esteves Pires, Felipe Serrão de Souza, Luiz Paulo Giorgetta de Faria, Pedro José Labronici, Alexandre Leme Godoy-Santos

    We investigated the biomechanical behaviour of different fixations of the tibial posterior malleolus (TPM), simulating distinct situations of involvement of the tibiotalar articular surface (TTAS) through a finite element model (FEM). A 3D computer-aided design model of the left ankle was obtained. The materials used were divided according to their characteristics into ductile and non-ductile, and all materials were assumed to be linear elastic, isotropic, and homogenous. Three different fracture lines of the TPM were defined, with sagittal angles of 10º, 25º, and 45º. For biomechanical comparison, different constructions using a trans-syndesmotic screw (TSS) only (Group T), a one-third tubular plate only with (Group PT) and without (Group PS) a TSS, and a locked compression plate with (Group LCPT) and without (Group LCPS) a TSS were tested. FEM was used to simulate the boundary conditions of vertical loading. Load application regions were selected in the direction of the 700N Z axis, 90% on the tibia and 10% on the fibula. Data on the displacement and stress in the FEM were collected, including the total principal maximum (MaxT) and total principal minimum (MinT) for non-ductile materials, total displacement (desT), localized displacement at the fragment (desL), localized displacement at syndesmosis (desS), and Von Mises equivalent stress for ductile materials. The data were analyzed using ANOVA and multiple comparison LSD tests were used. For TPM fractures with a sagittal angles 10º and 25º, desL in the PT and LCP groups was significantly lower, as well as Von Mises stress in Group LCPT in 10º, and PT and LCPT groups in 25º. TPM fractures with a sagittal angle of 45º, desL in the LCP group and Von Mises stress in Group LCPS and LCPT was significantly lower. We found that any TPM fracture may indicate instability of the distal tibiofibular syndesmosis, even when the fragment is small. Our study showed that in fragments involving 10% of the TTAS, the use of a TSS is sufficient, but when the involvement is greater than 25% of the TTAS, either non-locked or locked plate must be used to buttress the TPM. In posterior fragments affecting 45% or more of the TTAS, the use of a locking plate is recommended.

  • Open Access

    Deltoid tuberosity index obtained by computed tomography versus radiography for measuring bone quality in proximal humeral fractures: a retrospective observational study

    by Pedro José Labronici, Lucas Fávero Pereira, Guilherme Guimarães Cabral, Gabriela Sulz Magalhães, William Dias Belangero, Robinson Esteves Pires, Gustavo Waldolato Silva, George S. M. Dyer, Vincenzo Giordano

    Background In cases of proximal humeral fractures, fracture severity and the patient’s osteoporotic condition should be assessed to achieve the best possible treatment outcomes. The Tingart measurement is commonly used to assess bone quality, but it can be problematic if the measurement area is affected by the fracture. Recently, the deltoid tuberosity index (DTI) has been developed as another index to evaluate bone quality. The aim of this study was to compare the efficacy of the DTI obtained by X-ray imaging with computed tomography (CT) in assessing bone quality for proximal humeral fractures. Methods Fifteen patients with proximal humeral fractures were included, and the images were assessed twice by two independent evaluators with an interval of 1 month between each assessment. According to DTI values measured by X-ray, values greater than 1.4 were considered positive for osteoporosis, while values less than or equal to 1.4 were considered negative. The inclusion criteria were patients over 18 years old with a proximal humeral fracture who underwent anteroposterior radiography and CT. Pathological fractures, pre-existing humeral fractures, and metabolic diseases were excluded. Results There was good agreement between the CT and X-ray measurements. However, there were significant differences between them, with the CT measure being higher than the X-ray measure in 46.7% of the evaluations. The best cut-off points for diagnosing osteoporosis were found to be the same for CT and DTI: 1.4. CT diagnosis had an accuracy of 73.3%, a sensitivity of 65.2%, and a specificity of 78.4% when compared to X-ray diagnosis. False-positive diagnoses were 14.3%, and false-negative diagnoses were 13.3%. Conclusions CT can be considered a good method for diagnosing osteoporosis in proximal humeral fractures. The findings of this study allow the surgeon to use the CT as a new tool to make the diagnosis of osteoporosis and to define the patient under risk for surgical procedure.

  • Open Access

    Morphological Characteristics of Proximal Ulna Fractures: A Proposal for a New Classification and Agreement for Validation

    by Pedro José Labronici, William Dias Belangero, Carlos Miguel Zublin, Lucas Braga Jaques Gonçalves, Humberto Fajardo, Robinson Esteves Pires, Vincenzo Giordano

    Historically, proximal ulna fractures have been simplistically diagnosed and treated as simple olecranon fractures, leading to an unacceptable number of complications. Our hypothesis was that the recognition of lateral, intermediate, and medial stabilizers of the proximal ulna and ulnohumeral and proximal radioulnar joints would facilitate decision-making, including the choice of approach and type of fixation. The primary aim was to propose a new classification for complex fractures of the proximal ulna based on morphological characteristics seen on three-dimensional computed tomography (3D CT). The secondary aim was to validate the proposed classification regarding its intra- and inter-rater agreement. Three raters with different levels of experience analyzed 39 cases of complex fractures of the proximal ulna using radiographs and 3D CT scans. We presented the proposed classification (divided into four types with subtypes) to the raters. In this classification, the medial column of the ulna involves the sublime tubercle and is where the anterior medial collateral ligament is inserted, the lateral column contains the supinator crest and is where the lateral ulnar collateral ligament is inserted, and the intermediate column involves the coronoid process of the ulna, olecranon, and anterior capsule of the elbow. Intra- and inter-rater agreement was analyzed for two different rounds, and the results were evaluated according to Fleiss kappa, Cohen kappa, and Kendall coefficient. Intra- and inter-rater agreement values were very good (0.82 and 0.77, respectively). Good intra- and inter-rater agreement attested to the stability of the proposed classification among the raters, regardless of the level of experience of each one. The new classification proved to be easy to understand and had very good intra- and inter-rater agreement, regardless of the level of experience of each rater.


  • Open Access

    Computed Tomography Does Not Improve Intra- and Interobserver Agreement of Hertel Radiographic Prognostic Criteria

    by Paulo Ottoni di Tullio, Vincenzo Giordano, William Dias Belangero, Robinson Esteves Pires, Felipe Serrão de Souza, Pedro José Labronici, Caio Zamboni, Felipe Malzac, Paulo Santoro Belangero, Roberto Yukio Ikemoto, et al.

    Background and Objectives: Proximal humerus fractures are the second most frequent site of avascular necrosis (AVN), occurring in up to 16% of cases. The Hertel criteria have been used as a reference for the prediction of humerus head ischemia. However, these are based solely on the use of radiographs, which can make interpretation extremely difficult due to several reasons, such as the overlapping fragments, severity of the injury, and noncompliant acute pain patients. The objectives of the study were to evaluate the role of computed tomography (CT) in the interpretation of the Hertel criteria and to evaluate the intra- and interobserver agreement of orthopedic surgeons, comparing their area of expertise. Materials and Methods: The radiographs and CT scans of 20 skeletally mature patients who had fractures of the proximal humerus were converted to jpeg and mov, respectively. All images were evaluated by eight orthopedic surgeons (four trauma surgeons and four shoulder surgeons) in two different occasions. The intra- and interobserver agreement was assessed by using the Kappa coefficient. The level of significance was 5%. Results: There was a weak-to-moderate intraobserver agreement (κ < 0.59) for all examiners. Only the medial metaphyseal hinge greater than 2 mm was identified by 87.5% of evaluators both in the radiographic and CT examinations in the two rounds of the study (p < 0.05). There was no significant interobserver agreement (κ < 0.19), as it occurred only in some moments of the second round of evaluation. Conclusions: The prognostic criteria for humeral head ischemia evaluated in this study showed weak intra- and interobserver agreement in both the radiographic and tomographic evaluation. CT did not help surgeons in the primary interpretation of Hertel prognostic criteria used in this study when compared to the radiographic examination.