Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation
- 25 June 2011
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 7 (3) , 433-444
Abstract
Percutaneous scaphoid fixation (PSF) is growing in popularity as a treatment option for non-displaced fractures. Success of this procedure demands high-precision screw placement, which can be difficult to achieve with standard 2D imaging. This study aimed to develop and test a system for computer-assisted navigation using volume slicing of 3D cone-beam computed tomography (CBCT). The navigated technique involved a distinctive workflow in which a 3D CBCT imager was calibrated preoperatively, circumventing the need for intraoperative patient-based registration. Intraoperatively, a 3D CBCT image was acquired for both preoperative planning and direct navigation using volume-rendered slices. An in vitro study was conducted to compare the navigated approach to two conventional fluoroscopic methods for volar PSF. The surgical goal was to insert a guide wire to maximize both length and central placement. There was no significant difference in the mean central placement of guide wire, although the variance in central placement was significantly lower using VS navigation (P < 0.01). The lengths of the drill paths were significantly longer for the VS-navigated group compared with one 2D group (P < 0.1). Each navigated trial required only one drilling attempt and resulted in less radiation exposure than conventional C-arm (P < 0.01). Volume-sliced navigation achieved a more repeatable and reliable central pin placement, with fewer drilling attempts than conventional 2D techniques. Volume-sliced navigation had a higher number of drill paths within the optimal zone maximizing both length of the path and depth from the surface.Keywords
This publication has 37 references indexed in Scilit:
- Computer-Assisted 3-Dimensional Anthropometry of the ScaphoidOrthopedics, 2010
- A Computational Approach to the “Optimal” Screw Axis Location and Orientation in the Scaphoid BoneThe Journal of Hand Surgery, 2009
- Percutaneous Screw Fixation for Scaphoid Fracture: A Comparison Between the Dorsal and the Volar ApproachesThe Journal of Hand Surgery, 2009
- Kirschner wire placement in scaphoid bones using fluoroscopic navigation: a cadaver study comparing conventional techniques with navigationThe International Journal of Medical Robotics and Computer Assisted Surgery, 2008
- Experimental validation of noninvasive referencing in navigated procedures on long bonesJournal of Orthopaedic Research, 2006
- Screw Fixation of Scaphoid Fractures: A Biomechanical Assessment of Screw Length and Screw AugmentationThe Journal of Hand Surgery, 2006
- The Morphological and Morphometric Features of the ScaphoidJournal of Hand Surgery (European Volume), 2004
- Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placementJournal of Neurosurgery: Spine, 2003
- Surgical Navigation Based on Fluoroscopy—Clinical Application for Computer-Assisted Distal Locking of Intramedullary ImplantsComputer Aided Surgery, 2000
- Surgical navigation based on fluoroscopy?clinical application for computer-assisted distal locking of intramedullary implantsComputer Aided Surgery, 2000