500 MHz Inductive Birdcage RF Coil for Brain MRI: Design, Implementation and Validation
- 23 January 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (6) , 1983-1992
Abstract
Objective: We present a 500 MHz inductive birdcage RF resonator for imaging the human brain in an 11.7 T MRI scanner. Methods: A homogenous circularly polarized transmit field ($\text{B}_{1}^{+}$) was generated by transmitting power to the resonator through four couplers driven in differential mode and with an incremental 90-degree phase delay. A detailed mechanical and electrical model of the hardware, loaded with different phantoms, was generated and its performance simulated using a finite-difference time-domain method. Results: The head-size inductively coupled birdcage presented a fundamental mode at 500 MHz. MR thermometry maps were in good agreement with heating profiles estimated from simulated SAR maps Conclusion: The model of the hardware was validated through both bench and MRI measurements. Significance: This validation is important for future analysis of radiofrequency safety and performance at ultra-high field MRI through the prediction of SAR and $\text{B}_{1}^{+}$ profiles across different human brain models at various positions inside the coil.Keywords
Funding Information
- Intramural Research Program of the NINDS
- NIH
This publication has 39 references indexed in Scilit:
- Ideal current patterns yielding optimal signal‐to‐noise ratio and specific absorption rate in magnetic resonance imaging: Computational methods and physical insightsMagnetic Resonance in Medicine, 2011
- Local SAR in parallel transmission pulse designMagnetic Resonance in Medicine, 2011
- Design of a radiative surface coil array element at 7 T: The single‐side adapted dipole antennaMagnetic Resonance in Medicine, 2011
- Local specific absorption rate control for parallel transmission by virtual observation pointsMagnetic Resonance in Medicine, 2011
- Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readoutMagnetic Resonance in Medicine, 2010
- Parallel transmit and receive technology in high‐field magnetic resonance neuroimagingInternational Journal of Imaging Systems and Technology, 2010
- Exploring the limits of RF shimming for high‐field MRI of the human headMagnetic Resonance in Medicine, 2006
- Parallel excitation with an array of transmit coilsMagnetic Resonance in Medicine, 2004
- Transmit SENSEMagnetic Resonance in Medicine, 2002
- The design and test of a new volume coil for high field imagingMagnetic Resonance in Medicine, 1994