Effects of noise on transient-evoked oto-acoustic emission pass/fail criteria
Authors:
- 1 May 2002
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 40 (3) , 278-281
Abstract
This study investigated the effects of noise on typical transient-evoked oto-acoustic emission (TEOAE) pass/fail criteria. Different levels of synthesised noise were added to one TEOAE signal, to determine the relationship between the signal-to-noise ratio (SNR) and typical TEOAE parameters: reproducibility, TEOAE level and corrected TEOAE level. Results showed that, with the same TEOAE signal, if the SNR decreased from 19 dB to −7 dB, the means of estimated reproducibility decreased from 97% to 7%, and the means of estimated TEOAE levels were doubled. Only the means ofestimated corrected TEOAE levels were relatively insensitive to SNR. The standard deviations of all TEOAE parameter estimators increased with decreasing SNR. With these results, this study proposed that each typical TEOAE parameter alone should not be taken as the absolute pass/fail criterion. A combination of the corrected TEOAE level and the reproducibility would be better.Keywords
This publication has 12 references indexed in Scilit:
- Modification of the wavelet method used in transiently evoked otoacoustic emission pass/fail criterion to increase its accuracyMedical & Biological Engineering & Computing, 2002
- Data processing options and response scoring for OAE-based newborn hearing screeningThe Journal of the Acoustical Society of America, 2001
- The effects of noise in transient EOAE newborn hearing screeningInternational Journal of Pediatric Otorhinolaryngology, 1994
- Confirmation of Transiently Evoked Otoacoustic Emissions Based on User-Independent CriteriaInternational Journal of Audiology, 1994
- Analysis of transient-evoked otoacoustic emissions in normal-hearing and hearing-impaired earsThe Journal of the Acoustical Society of America, 1993
- Noise and signal power and their effects on evoked potential estimationElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1988
- Confidence intervals for the signal-to-noise ratio when a signal embedded in noise is observed over repeated trialsIEEE Transactions on Biomedical Engineering, 1988
- Quality Estimation of Averaged Auditory Brainstem ResponsesScandinavian Audiology, 1984
- Stimulated acoustic emissions from within the human auditory systemThe Journal of the Acoustical Society of America, 1978
- On estimating signal-to-noise ratio using the sample correlation coefficient (Corresp.)IEEE Transactions on Information Theory, 1974