Investigation on the pulse shape of DC corona discharges in air under varying test voltage level
Authors:
- 1 July 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
A continuous condition assessment of operating equipment makes a significant contribution to the service reliability. In this context the partial discharge diagnosis is of great importance. In contrast to AC applications an established diagnostic tool for DC applications does not exist, even though diverse promising approaches, such as the time domain analysis, are identified. This finding is based on investigations, which are carried out under a constant test voltage level. Consequently, additional research, considering a varying test voltage level and its influence on the pulse shape of partial discharges, is required to reach universally valid statements. Focusing on corona discharges in air, the investigations are carried out by using an optimized broadband measuring system. Whereas the corona discharges are gained from an artificial and idealized defect at high-voltage potential, the measuring system enables to capture the pulse shape devoid of reflection and refraction processes. As characterizing pulse shape parameters, the rise time, the pulse width and the fall time are determined as well as the apparent charge and the repetition rate. The gained values are compared to each other and discussed for different test voltage levels.Keywords
This publication has 8 references indexed in Scilit:
- Influence of humidity on pulse shape parameters of positive corona discharges in air at DC voltage2017
- Detection and distinction of partial discharges in air at DC voltage by using a non-conventional approach in the high-frequency range2017
- Investigation on the Applicability of the Time Domain Analysis of Discharges in Gases for the Defect Identification at AC VoltageTransactions on Environment and Electrical Engineering, 2016
- Effects of temperature and pressure change on positive corona and sparkover under direct voltage in short airgapsIET Science, Measurement & Technology, 2007
- Factors affecting corona on twin-point gaps under dc and ac HVIEEE Transactions on Dielectrics and Electrical Insulation, 1996
- Interpretation of partial discharges at dc voltagesIEEE Transactions on Dielectrics and Electrical Insulation, 1995
- Assessment of dielectric degradation by ultrawide-band PD detectionIEEE Transactions on Dielectrics and Electrical Insulation, 1995
- Ultrahigh frequency study of PD pulses1994