Influence of Near-Segment Positioning in a Rotationally Asymmetric Multifocal Intraocular Lens
Authors:
- In Seok SongISIn Seok Song
- Sam Young YoonSYSam Young Yoon
- Jae Yong KimJKJae Yong Kim
- Myoung Joon KimMKMyoung Joon Kim
- Hungwon TchahHTHungwon Tchah
- 1 April 2016
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 32 (4) , 238-243
Abstract
PURPOSE: To compare visual performance and higher order aberrations (HOAs) based on the position of the near segment in eyes with rotationally asymmetric multifocal intraocular lenses (IOLs). METHODS: Asymmetric multifocal IOLs (Lentis Mplus LS-313; Oculentis Optikgeräte GmbH, Wetzlar, Germany) were implanted with the near segment positioned either inferiorly, superiorly, or temporally. Uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuity, corrected distance visual acuity (CDVA), and distance-corrected intermediate (DCIVA) and near (DCNVA) visual acuity, contrast sensitivity, HOAs, and subjective symptom questionnaires were compared at 1 month postoperatively. RESULTS: Forty-five eyes from 45 patients were evaluated (n = 25, 9, and 11 eyes in the inferior, superior, and temporal groups, respectively). No significant differences in UDVA, UIVA, UNVA, CDVA, DCIVA, or DCNVA were found between the three groups ( P > .05). The temporal group showed the best results in UDVA, CDVA, and DCNVA, but the inferior group showed the best results in DCIVA and UNVA and the superior group showed the best results in UIVA. Contrast sensitivity and the subjective symptom questionnaire also did not demonstrate any significant differences ( P > .05). Total HOA and spherical aberration did not demonstrate any statistically significant differences ( P > .05), but vertical coma and horizontal coma demonstrated significant differences based on near segment position ( P < .001). CONCLUSIONS: The position of the near segment in eyes with rotationally asymmetric multifocal IOLs demonstrates no significant effect on visual performance. [ J Refract Surg. 2016;32(4):238–243.]Keywords
This publication has 17 references indexed in Scilit:
- Clinical and Optical Intraocular Performance of Rotationally Asymmetric Multifocal IOL Plate-Haptic Design Versus C-Loop Haptic DesignJournal of Refractive Surgery, 2013
- Visual outcomes with a single-optic accommodating intraocular lens and a low-addition-power rotational asymmetric multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2012
- Rotationally Asymmetric Multifocal IOL Implantation With and Without Capsular Tension Ring: Refractive and Visual Outcomes and Intraocular Optical PerformanceJournal of Refractive Surgery, 2012
- Comparison of a New Refractive Multifocal Intraocular Lens with an Inferior Segmental Near Add and a Diffractive Multifocal Intraocular LensOphthalmology, 2012
- Combining Zonal Refractive and Diffractive Aspheric Multifocal Intraocular LensesJournal of Refractive Surgery, 2012
- Visual function comparison of 2 aspheric multifocal intraocular lensesJournal of Cataract & Refractive Surgery, 2012
- Comparison of the Visual and Intraocular Optical Performance of a Refractive Multifocal IOL With Rotational Asymmetry and an Apodized Diffractive Multifocal IOLJournal of Refractive Surgery, 2012
- Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2011
- Multifocal intraocular lens with a surface-embedded near section: Short-term clinical outcomesJournal of Cataract & Refractive Surgery, 2011
- Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2011