Biomechanical Evaluation of Subcrestal Placement of Dental Implants: In Vitro and Numerical Analyses
- 1 February 2011
- journal article
- research article
- Published by Wiley in Journal of Periodontology
- Vol. 82 (2) , 302-310
Abstract
Background: This study investigates the effect of depth of insertion in subcrestal cortical bone (SB) and thickness of connected cortical bone (CB) for a subcrestal implant placement on bone stress and strain using statistical analyses combined with experimental strain‐gauge tests and numerical finite element (FE) simulations.Methods: Three experimental, artificial jawbone models and 72 FE models were prepared for evaluation of bone strain and stress around various equicrestal and subcrestal implants. For in vitro tests, rosette strain gauges were used with a data acquisition system to measure bone strain on the bucco‐lingual side. The maximum von Mises stresses in the bone were statistically analyzed by analysis of variance for FE models.Results: The experimental bone strains reduced significantly (22% to 49%) as the thickness of CB increased. FE analyses indicated that the suggested CB thickness for efficiently minimizing bone stress was 0.5 to 2.5 mm. The results for the depth of SB were not absolute because obvious stress reductions only presented at a certain range of depth (0.6 to 1.2 mm).Conclusion: Within the limitations of this study, increasing the thickness of CB and maintaining the depth of SB within a limited range can provide the benefit of decreasing the stress and strain in surrounding bone for subcrestally placed implants.Keywords
Funding Information
- National Science Council (NSC 98‐2320‐B‐039‐005‐MY3)
This publication has 26 references indexed in Scilit:
- Influence of interimplant distances and placement depth on peri‐implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogsClinical Oral Implants Research, 2010
- Bone Strain and Interfacial Sliding Analyses of Platform Switching and Implant Diameter on an Immediately Loaded Implant: Experimental and Three‐Dimensional Finite Element AnalysesJournal of Periodontology, 2009
- The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysisClinical Oral Investigations, 2009
- Subcrestal placement of two‐part implantsClinical Oral Implants Research, 2009
- Placement of Two‐Part Implants in Sites With Different Buccal and Lingual Bone HeightsJournal of Periodontology, 2009
- Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogsClinical Oral Implants Research, 2008
- Bone stress and interfacial sliding analysis of implant designs on an immediately loaded maxillary implant: A non-linear finite element studyJournal of Dentistry, 2008
- Biologic width changes around loaded implants inserted in different levels in relation to crestal bone: histometric evaluation in canine mandibleClinical Oral Implants Research, 2008
- Clinical and Radiographic Changes Around Dental Implants Inserted in Different Levels in Relation to the Crestal Bone, Under Different Restoration Protocols, in the Dog ModelJournal of Periodontology, 2008
- Spontaneous progression of experimentally induced periimplantitisJournal of Clinical Periodontology, 2004