Time Course of Corneal Biomechanical Parameters After Phacoemulsification With Intraocular Lens Implantation
Authors:
- Kimiya ShimizuKSKimiya Shimizu
- Fumiko OhmotoFOFumiko Ohmoto
- Rie AmanoRARie Amano
- 1 November 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Cornea
- Vol. 29 (11) , 1256-1260
Abstract
To assess the time course of corneal biomechanical parameters after phacoemulsification with intraocular lens implantation. We examined 54 eyes of 33 consecutive patients undergoing cataract surgery. We quantitatively assessed the values of corneal biomechanics characterized by corneal hysteresis (CH) and corneal resistance factor (CRF) using an Ocular Response Analyzer before and 1 day, 1 week, 1 month, and 3 months after surgery. We also investigated the relationship between these biomechanical parameters and central corneal thickness 3 months after surgery. The CH was 9.7 ± 1.1 (mean ± SD) mm Hg preoperatively, and 9.0 ± 1.4, 9.7 ± 1.1, 9.7 ± 1.1, and 9.7 ± 1.3 mm Hg 1 day, 1 week, 1 month, and 3 months postoperatively, respectively. The CRF was 9.5 ± 1.1 mm Hg preoperatively, and 8.8 ± 1.2, 9.2 ± 1.3, 9.1 ± 0.9, and 9.2 ± 1.2 mm Hg 1 day, 1 week, 1 month, and 3 months postoperatively, respectively. Multiple comparisons demonstrated significant differences between measurements made before and 1 day after surgery (P = 0.01 for CH and CRF, Dunnett test). Both CH and CRF were significantly correlated with central corneal thickness (Pearson correlation coefficient r = 0.29; P = 0.03 for CH and r = 0.42; P = 0.002 for CRF). Both CH and CRF decreased briefly at 1 day after cataract surgery but soon recovered to the preoperative levels, suggesting that cataract surgery does not induce a significant change in corneal biomechanics, except for 1 day postoperatively. The corneal thickness may play some role in corneal biomechanics even in postcataract eyes.Keywords
This publication has 19 references indexed in Scilit:
- Effect of Aging on Corneal Biomechanical Parameters Using the Ocular Response AnalyzerJournal of Refractive Surgery, 2009
- Corneal biomechanical properties and intraocular pressure changes after phacoemulsification and intraocular lens implantationJournal of Cataract & Refractive Surgery, 2008
- Influence of Corneal Structure, Corneal Responsiveness, and Other Ocular Parameters on Tonometric Measurement of Intraocular PressureJournal of Glaucoma, 2007
- Comparison of IOP Measurements Between ORA and GAT in Normal ChineseOptometry and Vision Science, 2007
- Assessment of the Biomechanical Properties of the Cornea with the Ocular Response Analyzer in Normal and Keratoconic EyesInvestigative Ophthalmology & Visual Science, 2007
- Biomechanics and wound healing in the corneaExperimental Eye Research, 2006
- Measuring intraocular pressure-adjustments for corneal thickness and new technologiesCurrent Opinion in Ophthalmology, 2006
- Determining in vivo biomechanical properties of the cornea with an ocular response analyzerJournal of Cataract & Refractive Surgery, 2005
- Interferometric technique to measure biomechanical changes in the cornea induced by refractive surgeryJournal of Cataract & Refractive Surgery, 2005
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005