Ultrasound imaging using single-element biaxial beamforming
- 23 December 2025
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (01) , 1-17
Abstract
PurposeDynamic focusing of received ultrasound signals, or beamforming, is foundational for ultrasound imaging. Conventionally, it requires arrays of ultrasound sensors to estimate where sound came from using time-of-flight (TOF) measurements. We demonstrate passive beamforming with a single biaxial sensor and accurate passive acoustic mapping with two biaxial sensors using only direction of arrival (DOA) information.ApproachWe introduce two single-element biaxial beamforming algorithms and four biaxial image reconstruction algorithms for a two-element biaxial piezoceramic transducer array. Imaging of a hemispherical acoustic source is characterized in an acoustic scanning tank within the region −30.29 mm ≤x≤ 29.94 mm and 50.11 mm ≤z≤ 90.45 mm relative to the center of the array. Imaging performance is contrasted with delay, sum, and integrate (DSAI) and delay, multiply, sum, and integrate (DMSAI) algorithms.ResultsSingle-element biaxial beamforming can identify DOA with a median error (± interquartile range) of 0.36±0.63 deg and median full-width half-prominence of 7.3±8.6 deg. Using both array elements, DOA-only images demonstrate overall median localization error of 6.41 mm (lateral: 1.02 mm, axial: 5.85 mm, signal-to-noise ratio (SNR): 15.37) and DOA + TOF images demonstrate overall median error of 6.91 mm (lateral: 1.69 mm, axial: 6.11 mm, SNR: 18.37).ConclusionsTo the best of our knowledge, we provide the first demonstration of single-element beamforming using a single stationary piezoceramic and the first demonstration of passive ultrasound imaging without the use of TOF information. These results enable simpler, smaller, more cost-effective arrays for passive ultrasound imaging.Keywords
Funding Information
- Collaborative Health Research Projects Program
- Natural Sciences and Engineering Research Council of Canada (RGPIN-2019-04387)
- Canadian Foundation for Innovation (36073)
This publication has 15 references indexed in Scilit:
- Guiding and monitoring focused ultrasound mediated blood–brain barrier opening in rats using power Doppler imaging and passive acoustic mappingScientific Reports, 2022
- Acoustic characterization of cavitation intensity: A reviewUltrasonics Sonochemistry, 2021
- Steering single-element lead zirconate titanate ultrasound transducers using biaxial drivingUltrasonics, 2021
- Delay multiply and sum beamforming method applied to enhance linear‐array passive acoustic mapping of ultrasound cavitationMedical Physics, 2019
- Passive acoustic mapping utilizing optimal beamforming in ultrasound therapy monitoringThe Journal of the Acoustical Society of America, 2015
- Passive acoustic mapping of magnetic microbubbles for cavitation enhancement and localizationPhysics in Medicine & Biology, 2015
- Spatiotemporal evolution of cavitation dynamics exhibited by flowing microbubbles during ultrasound exposureThe Journal of the Acoustical Society of America, 2012
- Ultrasound-Induced Blood-Brain Barrier OpeningCurrent Pharmaceutical Biotechnology, 2012
- Passive cavitation imaging with ultrasound arraysThe Journal of the Acoustical Society of America, 2009
- Passive Spatial Mapping of Inertial Cavitation During HIFU ExposureIEEE Transactions on Biomedical Engineering, 2009