Laura Curiel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laura Curiel has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Samuel Pichardo
University of Calgary
13 shared publications - Jesús Enrique Chong Quero
Campus Estado de México School of Engineering and Sciences, Tecnologico de Monterrey Atizapán de Zaragoza
4 shared publications - Albert Gelet
Urology Department, Hospices Civils De Lyon, Lyon, France
3 shared publications - Arturo Vargas-Olivares
Tecnologico de Monterrey, School of Engineering and Sciences, Mexico
3 shared publications - Jean-Yves Chapelon
INSERM, Lyon, France
3 shared publications - Sagid Delgado
Department of Radiology, University of Calgary, Calgary, Canada
3 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by Elsevier in SSRN Electronic Journal
Fourier Neural Operator with Physics-Informed Regularizer for Rapid, Multi-Frequency Transcranial Focused Ultrasound Prediction
Transcranial focused ultrasound (tFUS) is a promising non-invasive neuromodulation technique, but subject-specific treatment planning relies on full-wave acoustic simulators that must be re-run for each subject, target, and frequency, too slow for interactive use. We address this with tFUS-FNO, a Fourier neural operator (FNO) that predicts the full three-dimensional complex pressure field directly from subject-specific computed tomography (CT)-derived acoustic maps, including the field within the skull, not just the deep-brain target. The contribution is a staged training curriculum that progressively adds an $H^1$ (Sobolev) smoothness term and a self-supervised Helmholtz-equation residual regularizer, applied separately at 250, 500, and 750~kHz. Models are trained on full-wave BabelBrain simulations using a subject-wise split of 94 subjects (64/15/15), each with 50 targets from the International 10--10 electroencephalography (EEG) electrode placement system, spanning favorable and acoustically challenging skull regions. On 750 held-out subject--target pairs per frequency, field-similarity accuracy decreases with frequency, from a relative $\ell^2$ error of $9.90 \pm 4.44$\% and structural similarity index measure (SSIM) of $0.95 \pm 0.04$ at 250~kHz to $17.46 \pm 5.15$\% and $0.88 \pm 0.05$ at 750~kHz; focal targeting remains accurate and largely frequency-independent, with median localization within a millimetre of ground truth. Inference is sub-second on GPUs---two to three orders of magnitude faster than full-wave simulation---and completes in seconds on consumer hardware. These results support tFUS-FNO as a fast, deployable planning tool complementing full-wave simulation.- 21 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFourier Neural Operator with Physics-Informed Regularizer for Rapid, Multi-Frequency Transcranial Focused Ultrasound Prediction
Transcranial focused ultrasound (tFUS) is a promising non-invasive neuromodulation technique, but subject-specific treatment planning relies on full-wave acoustic simulators that must be re-run for each subject, target, and frequency, too slow for interactive use. We address this with tFUS-FNO, a Fourier neural operator (FNO) that predicts the full three-dimensional complex pressure field directly from subject-specific computed tomography (CT)-derived acoustic maps, including the field within the skull, not just the deep-brain target. The contribution is a staged training curriculum that progressively adds an $H^1$ (Sobolev) smoothness term and a self-supervised Helmholtz-equation residual regularizer, applied separately at 250, 500, and 750~kHz. Models are trained on full-wave BabelBrain simulations using a subject-wise split of 94 subjects (64/15/15), each with 50 targets from the International 10--10 electroencephalography (EEG) electrode placement system, spanning favorable and acoustically challenging skull regions. On 750 held-out subject--target pairs per frequency, field-similarity accuracy decreases with frequency, from a relative $\ell^2$ error of $9.90 \pm 4.44$\% and structural similarity index measure (SSIM) of $0.95 \pm 0.04$ at 250~kHz to $17.46 \pm 5.15$\% and $0.88 \pm 0.05$ at 750~kHz; focal targeting remains accurate and largely frequency-independent, with median localization within a millimetre of ground truth. Inference is sub-second on GPUs---two to three orders of magnitude faster than full-wave simulation---and completes in seconds on consumer hardware. These results support tFUS-FNO as a fast, deployable planning tool complementing full-wave simulation. - 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. PP, 1
Geometry-Driven Design of Biaxial Piezoelectric Transducers for Acoustic Beam Steering
Biaxial driving is a promising alternative to conventional phased arrays for acoustic beam steering, utilizing orthogonal electric fields on a single piezoelectric element. However, achieving effective steering currently relies on empirical trial-and-error due to a lack of systematic design methodologies correlating transducer geometry with directional resonance behavior. In this work, the electromechanical and acoustic response of rectangular piezoceramic transducers is investigated through finite element simulations and experimental validation. The influence of the ratio between lateral dimension and thickness is examined across multiple geometries to evaluate its effect on the interaction between propagation and lateral resonance modes. We fabricated and characterized transducers with different lateral sizes and thicknesses to assess beam steering performance. The results show that acoustic steering is strongly dependent on geometry and can be systematically controlled. When the lateral dimension-to-thickness ratio lies between approximately 0.9 and 2, the fundamental propagation and lateral resonances converge while maintaining strong modal coupling, enabling efficient beam deflection. Under these conditions, steering angles of up to ±50° are achieved in both simulations and experiments. Outside this range, weaker modal interaction results in limited steering capability. These findings identify geometric scaling as a key design parameter for resonance engineering and provide a practical framework for the development of compact, electronically steerable piezoelectric transducers for ultrasound applications.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. PP, 1
Geometry-Driven Design of Biaxial Piezoelectric Transducers for Acoustic Beam Steering
Biaxial driving is a promising alternative to conventional phased arrays for acoustic beam steering, utilizing orthogonal electric fields on a single piezoelectric element. However, achieving effective steering currently relies on empirical trial-and-error due to a lack of systematic design methodologies correlating transducer geometry with directional resonance behavior. In this work, the electromechanical and acoustic response of rectangular piezoceramic transducers is investigated through finite element simulations and experimental validation. The influence of the ratio between lateral dimension and thickness is examined across multiple geometries to evaluate its effect on the interaction between propagation and lateral resonance modes. We fabricated and characterized transducers with different lateral sizes and thicknesses to assess beam steering performance. The results show that acoustic steering is strongly dependent on geometry and can be systematically controlled. When the lateral dimension-to-thickness ratio lies between approximately 0.9 and 2, the fundamental propagation and lateral resonances converge while maintaining strong modal coupling, enabling efficient beam deflection. Under these conditions, steering angles of up to ±50° are achieved in both simulations and experiments. Outside this range, weaker modal interaction results in limited steering capability. These findings identify geometric scaling as a key design parameter for resonance engineering and provide a practical framework for the development of compact, electronically steerable piezoelectric transducers for ultrasound applications.
- 23 December 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (01) , 1-17
Ultrasound imaging using single-element biaxial beamforming
PurposeDynamic focusing of received ultrasound signals, or beamforming, is foundational for ultrasound imaging. Conventionally, it requires arrays of ultrasound sensors to estimate where sound came from using time-of-flight (TOF) measurements. We demonstrate passive beamforming with a single biaxial sensor and accurate passive acoustic mapping with two biaxial sensors using only direction of arrival (DOA) information.ApproachWe introduce two single-element biaxial beamforming algorithms and four biaxial image reconstruction algorithms for a two-element biaxial piezoceramic transducer array. Imaging of a hemispherical acoustic source is characterized in an acoustic scanning tank within the region −30.29 mm ≤x≤ 29.94 mm and 50.11 mm ≤z≤ 90.45 mm relative to the center of the array. Imaging performance is contrasted with delay, sum, and integrate (DSAI) and delay, multiply, sum, and integrate (DMSAI) algorithms.ResultsSingle-element biaxial beamforming can identify DOA with a median error (± interquartile range) of 0.36±0.63 deg and median full-width half-prominence of 7.3±8.6 deg. Using both array elements, DOA-only images demonstrate overall median localization error of 6.41 mm (lateral: 1.02 mm, axial: 5.85 mm, signal-to-noise ratio (SNR): 15.37) and DOA + TOF images demonstrate overall median error of 6.91 mm (lateral: 1.69 mm, axial: 6.11 mm, SNR: 18.37).ConclusionsTo the best of our knowledge, we provide the first demonstration of single-element beamforming using a single stationary piezoceramic and the first demonstration of passive ultrasound imaging without the use of TOF information. These results enable simpler, smaller, more cost-effective arrays for passive ultrasound imaging.
- 23 December 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (01) , 1-17
Ultrasound imaging using single-element biaxial beamforming
PurposeDynamic focusing of received ultrasound signals, or beamforming, is foundational for ultrasound imaging. Conventionally, it requires arrays of ultrasound sensors to estimate where sound came from using time-of-flight (TOF) measurements. We demonstrate passive beamforming with a single biaxial sensor and accurate passive acoustic mapping with two biaxial sensors using only direction of arrival (DOA) information.ApproachWe introduce two single-element biaxial beamforming algorithms and four biaxial image reconstruction algorithms for a two-element biaxial piezoceramic transducer array. Imaging of a hemispherical acoustic source is characterized in an acoustic scanning tank within the region −30.29 mm ≤x≤ 29.94 mm and 50.11 mm ≤z≤ 90.45 mm relative to the center of the array. Imaging performance is contrasted with delay, sum, and integrate (DSAI) and delay, multiply, sum, and integrate (DMSAI) algorithms.ResultsSingle-element biaxial beamforming can identify DOA with a median error (± interquartile range) of 0.36±0.63 deg and median full-width half-prominence of 7.3±8.6 deg. Using both array elements, DOA-only images demonstrate overall median localization error of 6.41 mm (lateral: 1.02 mm, axial: 5.85 mm, signal-to-noise ratio (SNR): 15.37) and DOA + TOF images demonstrate overall median error of 6.91 mm (lateral: 1.69 mm, axial: 6.11 mm, SNR: 18.37).ConclusionsTo the best of our knowledge, we provide the first demonstration of single-element beamforming using a single stationary piezoceramic and the first demonstration of passive ultrasound imaging without the use of TOF information. These results enable simpler, smaller, more cost-effective arrays for passive ultrasound imaging.
- 19 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (2) , 314-322
Biaxial Excitation and Reception Method Applied to Ultrasound Imaging
The biaxial method consists of the utilization of orthogonal electric fields in single-element piezoceramics both in transmission and reception. This study demonstrates the application of the biaxial method to broadband transducers. We developed a three-element biaxial transducer array to demonstrate the feasibility of biaxial method in imaging applications. Finite element analysis was used to model the response of a single transducer element. An electric characterization was performed at each transducer element to determine their driving frequency. Each transducer was driven at 6.25 MHz and tested in different phases to determine the phase that produced the maximum pressure amplitude and shortest pulsewidth. Both simulations and experimental results showed that the acoustic pressure and half-pulsewidth followed a sinusoidal response as a function of the difference in phase applied to the lateral electrodes, as it has been described in our previous work. An imaging test was performed by placing a 0.36-mm diameter nylon wire 20 mm away from the transducer while driving and receiving each element with different combinations of conventional and biaxial driving. By applying a biaxial rephasing at the receiving electrodes during the data analysis, we obtained a maximum reduction in the axial resolution from 4.6 to 1.3 mm and signal-to-noise ratio (SNR) improvements from 15.2 to 24.4 dB, when compared to conventional driving.
- 19 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (2) , 314-322
Biaxial Excitation and Reception Method Applied to Ultrasound Imaging
The biaxial method consists of the utilization of orthogonal electric fields in single-element piezoceramics both in transmission and reception. This study demonstrates the application of the biaxial method to broadband transducers. We developed a three-element biaxial transducer array to demonstrate the feasibility of biaxial method in imaging applications. Finite element analysis was used to model the response of a single transducer element. An electric characterization was performed at each transducer element to determine their driving frequency. Each transducer was driven at 6.25 MHz and tested in different phases to determine the phase that produced the maximum pressure amplitude and shortest pulsewidth. Both simulations and experimental results showed that the acoustic pressure and half-pulsewidth followed a sinusoidal response as a function of the difference in phase applied to the lateral electrodes, as it has been described in our previous work. An imaging test was performed by placing a 0.36-mm diameter nylon wire 20 mm away from the transducer while driving and receiving each element with different combinations of conventional and biaxial driving. By applying a biaxial rephasing at the receiving electrodes during the data analysis, we obtained a maximum reduction in the axial resolution from 4.6 to 1.3 mm and signal-to-noise ratio (SNR) improvements from 15.2 to 24.4 dB, when compared to conventional driving.
- Open Access
- 19 September 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (19) , 195006
Biaxial ultrasound driving technique for small animal blood–brain barrier opening
Biaxial driving can more efficiently convert electrical power to forward acoustic power in piezoelectric materials, and the interaction between the orthogonal electric fields can produce a combination of extensional and shear deformations as a function of the phase difference between them to allow dynamic steering of the beam with a single-element. In this study, we demonstrate for the first time the application of a single-element biaxially driven ring transducer in vivo for blood–brain barrier opening in mice, and compare it to that achieved with a conventional single-element highly focused (F# = 0.7) spherical transducer operating at a similar frequency. Transcranial focused ultrasound (0.45 MPa, 10 ms pulse length, 1 Hz repetition frequency, 30 s duration) was applied bilaterally to mice with a 40 μl/kg bolus of DefinityTM microbubbles, employing either a single-element biaxial ring (1.482 MHz, 10 mm inner diameter, 13.75 mm outer diameter) or spherical (1.5 MHz, 35 mm diameter, F# = 0.7; RK50, FUS Instruments) transducer on each side. Follow-up MRI scans (T1 pre- and post- 0.2 mmol/kg Gd injection, T2) were acquired to assess blood–brain barrier opening volume and potential damage. Compared to blood–brain barrier opening achieved with a conventional single-element spherical focused transducer, the opening volume achieved with a single-element biaxial ring transducer was 35% smaller (p = 0.002) with a device of a ring diameter of 40% the aperture size. Axial refocusing was further demonstrated with the single-element biaxial ring transducer, yielding a 1.63 mm deeper, five-fold larger opening volume (p = 0.048) relative to its small-focus mode. The biaxial ring transducer achieved a more localized opening compared to the spherical focused transducer under the same parameters, and further enabled dynamic axial refocusing with a single-element transducer with a smaller fabrication footprint.
- 19 September 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (19) , 195006
Open AccessBiaxial ultrasound driving technique for small animal blood–brain barrier opening
Biaxial driving can more efficiently convert electrical power to forward acoustic power in piezoelectric materials, and the interaction between the orthogonal electric fields can produce a combination of extensional and shear deformations as a function of the phase difference between them to allow dynamic steering of the beam with a single-element. In this study, we demonstrate for the first time the application of a single-element biaxially driven ring transducer in vivo for blood–brain barrier opening in mice, and compare it to that achieved with a conventional single-element highly focused (F# = 0.7) spherical transducer operating at a similar frequency. Transcranial focused ultrasound (0.45 MPa, 10 ms pulse length, 1 Hz repetition frequency, 30 s duration) was applied bilaterally to mice with a 40 μl/kg bolus of DefinityTM microbubbles, employing either a single-element biaxial ring (1.482 MHz, 10 mm inner diameter, 13.75 mm outer diameter) or spherical (1.5 MHz, 35 mm diameter, F# = 0.7; RK50, FUS Instruments) transducer on each side. Follow-up MRI scans (T1 pre- and post- 0.2 mmol/kg Gd injection, T2) were acquired to assess blood–brain barrier opening volume and potential damage. Compared to blood–brain barrier opening achieved with a conventional single-element spherical focused transducer, the opening volume achieved with a single-element biaxial ring transducer was 35% smaller (p = 0.002) with a device of a ring diameter of 40% the aperture size. Axial refocusing was further demonstrated with the single-element biaxial ring transducer, yielding a 1.63 mm deeper, five-fold larger opening volume (p = 0.048) relative to its small-focus mode. The biaxial ring transducer achieved a more localized opening compared to the spherical focused transducer under the same parameters, and further enabled dynamic axial refocusing with a single-element transducer with a smaller fabrication footprint.
- 1 June 2023
- Published by Elsevier in Ultrasonics
- Vol. 133, 107051
Higher harmonics dynamic focalization in single-element ring transducers using biaxial driving
- 1 June 2023
- Published by Elsevier in Ultrasonics
- Vol. 133, 107051
Higher harmonics dynamic focalization in single-element ring transducers using biaxial driving
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (2) , 164-172
Passive Directivity Detection Using Individual Biaxial Ultrasound Transducers
Biaxial transducers are an emerging technology that can steer generated ultrasound waves using a single piezoceramic component. Simulations have also shown that biaxial transducers can passively estimate the direction of arrival of sound waves when operating in receive mode. This research seeks to experimentally verify biaxial directivity estimates and establish directivity as an independent parameter detected by biaxial transducers. Three cuboid (3.84 mm x 3.84 mm x 5.92 mm) biaxial piezoceramics with two pairs of orthogonal electrodes (one pair applied laterally and one pair applied in the polling direction) were manufactured and characterized. Each transducer was placed in a water tank where an independent hemispherical source was attached to a moveable arm and operated at 250 kHz. Terminal voltages were recorded for eighty-one source positions in a plane parallel to the transducer’s front face and at a depth of approximately 9 cm. Collection was repeated three times per transducer to ensure reproducibility. In-silico results were compared with the experimental results. Two derived metrics were then calculated using both the forward and lateral terminal voltages: the phase difference and amplitude ratio. Biaxial transducers demonstrate an ability to estimate the direction of arrival of incident sound waves, independently of any time-of-flight information. The phase difference and amplitude ratio complement each other to provide statistically significant and repeatable estimates over a range of 48 degrees (from -24 degrees to +24 degrees). These results can be used to augment a variety of medical, geophysical, and industrial passive ultrasound imaging techniques.
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (2) , 164-172
Passive Directivity Detection Using Individual Biaxial Ultrasound Transducers
Biaxial transducers are an emerging technology that can steer generated ultrasound waves using a single piezoceramic component. Simulations have also shown that biaxial transducers can passively estimate the direction of arrival of sound waves when operating in receive mode. This research seeks to experimentally verify biaxial directivity estimates and establish directivity as an independent parameter detected by biaxial transducers. Three cuboid (3.84 mm x 3.84 mm x 5.92 mm) biaxial piezoceramics with two pairs of orthogonal electrodes (one pair applied laterally and one pair applied in the polling direction) were manufactured and characterized. Each transducer was placed in a water tank where an independent hemispherical source was attached to a moveable arm and operated at 250 kHz. Terminal voltages were recorded for eighty-one source positions in a plane parallel to the transducer’s front face and at a depth of approximately 9 cm. Collection was repeated three times per transducer to ensure reproducibility. In-silico results were compared with the experimental results. Two derived metrics were then calculated using both the forward and lateral terminal voltages: the phase difference and amplitude ratio. Biaxial transducers demonstrate an ability to estimate the direction of arrival of incident sound waves, independently of any time-of-flight information. The phase difference and amplitude ratio complement each other to provide statistically significant and repeatable estimates over a range of 48 degrees (from -24 degrees to +24 degrees). These results can be used to augment a variety of medical, geophysical, and industrial passive ultrasound imaging techniques.
- Open Access
- 14 July 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (14) , 145015
Investigation of hardware and software techniques to enhance the characteristics of focused ultrasound (FUS) spectra
Objective . Microbubble cavitation generated by focused ultrasound ( FUS ) can induce safe blood-brain-barrier ( BBB ) opening allowing therapeutic drug passage. Spectral changes in the hydrophone sensor signal are currently used to distinguish stable cavitation from inertial cavitation that can damage the BBB. Gibbs’ ringing, peak intensity loss and peak width increase are well-known distortions evident when using the discrete Fourier transform ( DFT ) to transform data containing a few hundred points. We investigate overcoming the fact that FUS time signals (10 ms providing 312 500 points sampled at 32 ns intervals) can generate such sharp spectral peaks that variations in their DFT- related distortions can significantly impact the values of the key metrics used for cavitation characterization. Approach . We introduce low-pass filter hardware to improve how the analogue to digital convertor handles high-frequency noise components and the orders of magnitude differences between FUS harmonic intensities. We investigate the enhanced FUS spectral stability and resolution obtained from a new technique, physical sparsification (PH-SP), customized to the a-priori information that all key FUS components are harmonically related. Results are compared with standard DFT optimizations involving time data windowing and Fourier interpolation. Main results . A new simulation model showed peak intensity, widths and metrics modified by small changes in the transformed signal’s length when removing the noisy starting transient of the FUS hydrophone signal or following minor excitation frequency or sampling rate adjustments. 25%–60% area-under-the-curve changes occurred in phantom studies at different pressure levels. Spectral peak sharpness was best optimized and stabilized with PH-SP . Significance . Special FUS characteristics mean starting transients and minor variations in experimental procedures lead to significant changes in the spectral metrics used to monitor cavitation levels. Customizing PH-SP to these characteristics led to sharper, more stable spectra with the potential to track the impact of microbubble environment changes.
- 14 July 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (14) , 145015
Open AccessInvestigation of hardware and software techniques to enhance the characteristics of focused ultrasound (FUS) spectra
Objective . Microbubble cavitation generated by focused ultrasound ( FUS ) can induce safe blood-brain-barrier ( BBB ) opening allowing therapeutic drug passage. Spectral changes in the hydrophone sensor signal are currently used to distinguish stable cavitation from inertial cavitation that can damage the BBB. Gibbs’ ringing, peak intensity loss and peak width increase are well-known distortions evident when using the discrete Fourier transform ( DFT ) to transform data containing a few hundred points. We investigate overcoming the fact that FUS time signals (10 ms providing 312 500 points sampled at 32 ns intervals) can generate such sharp spectral peaks that variations in their DFT- related distortions can significantly impact the values of the key metrics used for cavitation characterization. Approach . We introduce low-pass filter hardware to improve how the analogue to digital convertor handles high-frequency noise components and the orders of magnitude differences between FUS harmonic intensities. We investigate the enhanced FUS spectral stability and resolution obtained from a new technique, physical sparsification (PH-SP), customized to the a-priori information that all key FUS components are harmonically related. Results are compared with standard DFT optimizations involving time data windowing and Fourier interpolation. Main results . A new simulation model showed peak intensity, widths and metrics modified by small changes in the transformed signal’s length when removing the noisy starting transient of the FUS hydrophone signal or following minor excitation frequency or sampling rate adjustments. 25%–60% area-under-the-curve changes occurred in phantom studies at different pressure levels. Spectral peak sharpness was best optimized and stabilized with PH-SP . Significance . Special FUS characteristics mean starting transients and minor variations in experimental procedures lead to significant changes in the spectral metrics used to monitor cavitation levels. Customizing PH-SP to these characteristics led to sharper, more stable spectra with the potential to track the impact of microbubble environment changes.
- Open Access
- 13 December 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (24) , 245011
Breast tissue mimicking phantoms for combined ultrasound and microwave imaging
We present a new formulation for a breast tissue-mimicking phantom for combined microwave and ultrasound imaging to assist breast cancer detection. Formulations based on coconut oil, canola oil, agar and glass beads were used to mimic skin and fat tissues. First, 36 recipes were fabricated, and properties were measured to determine the relationship and possible interaction between ingredients with the ultrasound and microwave properties. Based on these results, the formulae were developed to mimic different tissues found in breast, including skin, fat, fibroglandular, and tumour tissues. All phantoms contained a base of agar and glass beads at different proportions depending on the tissue mimicked. Tumour and fibroglandular tissues were best mimicked by adding polyvinylpyrrolidone (PVP), while using coconut oil for skin and canola oil for fat produced the best results. Five final phantoms with different internal structures were fabricated and imaged using B-mode ultrasound and a microwave transmission system. Microwave permittivity maps were obtained from the microwave system and compared to ultrasound images. The structure and composition of the phantoms were all confirmed through this microwave and ultrasound imaging.
- 13 December 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (24) , 245011
Open AccessBreast tissue mimicking phantoms for combined ultrasound and microwave imaging
We present a new formulation for a breast tissue-mimicking phantom for combined microwave and ultrasound imaging to assist breast cancer detection. Formulations based on coconut oil, canola oil, agar and glass beads were used to mimic skin and fat tissues. First, 36 recipes were fabricated, and properties were measured to determine the relationship and possible interaction between ingredients with the ultrasound and microwave properties. Based on these results, the formulae were developed to mimic different tissues found in breast, including skin, fat, fibroglandular, and tumour tissues. All phantoms contained a base of agar and glass beads at different proportions depending on the tissue mimicked. Tumour and fibroglandular tissues were best mimicked by adding polyvinylpyrrolidone (PVP), while using coconut oil for skin and canola oil for fat produced the best results. Five final phantoms with different internal structures were fabricated and imaged using B-mode ultrasound and a microwave transmission system. Microwave permittivity maps were obtained from the microwave system and compared to ultrasound images. The structure and composition of the phantoms were all confirmed through this microwave and ultrasound imaging.
- Open Access
- 1 February 2021
- Published by Elsevier in Ultrasonics
- Vol. 110, 106241
Steering single-element lead zirconate titanate ultrasound transducers using biaxial driving
- 1 February 2021
- Published by Elsevier in Ultrasonics
- Vol. 110, 106241
Open AccessSteering single-element lead zirconate titanate ultrasound transducers using biaxial driving