A 4-Decade-Tunable High-Selectivity Gm -C Bandpass Filter for Simultaneous Multi-Sine Bioimpedance Analysis
- 21 November 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 71 (1) , 160-173
Abstract
A bandpass filter (BPF), with high quality factor ( Q ) and wide tuning range of the centre frequency ( $f_0$ ), for signal separation in simultaneous multi-sine bioimpedance analysis, is presented. The cell follows the $G_m$ - C approach, where a multiple-output transconductor has been incorporated, for the sake of compactness, and a fully-differential structure has been selected, to enhance the general performance of the solution. The linearized transconductors ( $G_m$ ) are based on a double asymmetric differential pair and the integrated capacitors ( C ) are implemented in such a way that the required transfer function for the differential-mode signal is achieved and the stability of the common-mode component is granted. The BPF has been designed and fabricated in 180 nm CMOS technology to operate with a 1.8-V supply and feature a nominal gain at $f_0$ of 0 dB and a Q equal to 20, whereas $f_0$ is programmed by modifying the biasing current of the transconductors. Experimental results, measured on 8 samples of the silicon prototype, show that the BPF centre frequency can be continuously swept from 102 Hz to 2.06 MHz with a supply current ranging between 981 nA and 686 $\mu$ A. Besides, the maximum output voltage range of the filter, determined according to the –40 dB THD criterion, varies between around 31.5 mV and 64 mV within the frequency range indicated, thus leading to a dynamic range between 42.3 dB and 48.6 dB, which illustrates its suitability for the target application.Keywords
Funding Information
- MCIN/AEI/10 (0000DONOTUSETHIS0000.13039/501100011033)
- European Union NextGenerationEU/PRTR (TED2021-132372B-I00)
This publication has 61 references indexed in Scilit:
- An Integrated Analog Readout for Multi-Frequency Bioimpedance MeasurementsIEEE Sensors Journal, 2014
- An Amplitude-to-Time Conversion Technique Suitable for Multichannel Data Acquisition and Bioimpedance ImagingIEEE Transactions on Biomedical Circuits and Systems, 2012
- Optimal multisine excitation design for broadband electrical impedance spectroscopyMeasurement Science and Technology, 2011
- An ultra-low-power CMOS symmetrical OTA for low-frequency G m -C applicationsAnalog Integrated Circuits and Signal Processing, 2011
- Design of a CMOS closed-loop system with applications to bio-impedance measurementsMicroelectronics Journal, 2010
- A 30 pA/V– linear CMOS channel-length-modulation OTAMicroelectronics Journal, 2009
- An ultra low power CMOS pA/V transconductor and its application to wavelet filtersAnalog Integrated Circuits and Signal Processing, 2008
- A Wide Tuning Range $G_{m}$ –$C$ Continuous-Time Analog FilterIEEE Transactions on Circuits and Systems I: Regular Papers, 2007
- Design and preliminary evaluation of a portable device for the measurement of bioimpedance spectroscopyPhysiological Measurement, 2006
- Nanowatt, Sub-nS OTAs, With Sub-10-mV Input Offset, Using Series-Parallel Current MirrorsIEEE Journal of Solid-State Circuits, 2006